conditions: REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 prints the product code and no separate part number.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Frame
Anodized aluminum (black) with silver support bars
Printed as "Frame: Anodized aluminum (black) with silver support bars", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, General Data, Frame row
Printed in the 375 column of the STC table, row "Nominal Power Current - IMPP (A)" (10.72), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Electrical Data (STC), Nominal Power Current - IMPP (A) row, 375 column
Printed in the 375 column of the STC table, row "Short Circuit Current - ISC (A)" (11.45), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Electrical Data (STC), Short Circuit Current - ISC (A) row, 375 column
Printed in the 375 column of the STC table, row "Nominal Power Voltage - VMPP (V)" (35.0), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Electrical Data (STC), Nominal Power Voltage - VMPP (V) row, 375 column
Printed in the 375 column of the STC table, row "Open Circuit Voltage - VOC (V)" (41.2), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Electrical Data (STC), Open Circuit Voltage - VOC (V) row, 375 column
Cell description as printed ("Cell type: 120 half-cut mono c-Si p-type cells, 6 strings of 20 cells in series"), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, General Data, Cell type row
Printed as "Weight: 20.0 kg", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, General Data, Weight row
Printed as "Cell type: 120 half-cut mono c-Si p-type cells, 6 strings of 20 cells in series", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, General Data, Cell type row
Stäubli MC4 PV-KBT4/KST4, 12 AWG(4 mm²) in accordance with IEC 62852 IP68 only when connected
Printed in REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021. The IEC 62852 reference is a component statement and is not recorded as a module certification.
0.13” (3.2 mm) solar glass with anti-reflection surface treatment
Printed as "Glass: 0.13” (3.2 mm) solar glass with anti-reflection surface treatment" in REC Group's REC375TP4 datasheet (REC TwinPeak 4 Series datasheet, US edition (Ref: PM-DS-07-28 Rev- C 08.21) (Internet Archive copy, October 27, 2021)), captured on September 28, 2026.
3-part, 3 bypass diodes, IP68 rated in accordance with IEC 62790
Printed in REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021. The IEC 62790 reference is the datasheet's statement about that component and is not recorded as a module certification.
A framed glass module: the General Data table prints "Glass: 3.2 mm solar glass with anti-reflective surface treatment in accordance with EN 12150" and "Frame: Anodized aluminum (black) with silver support bars", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, General Data, Glass and Frame rows
A test load, printed as "Maximum test load (rear): - 4000 Pa (407 kg/m²)" (recorded as the magnitude); REC notes design load = test load / 1.5 (safety factor), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Maximum Ratings, Maximum test load (rear) row
Printed as "Backsheet: Highly resistant polymeric construction" in REC Group's REC375TP4 datasheet (REC TwinPeak 4 Series datasheet, US edition (Ref: PM-DS-07-28 Rev- C 08.21) (Internet Archive copy, October 27, 2021)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Backsheet row
W 1,040 × L 1,755 × D 30 mm / W 40.94 × L 69.09 × D 1.2 in converted
Printed as "Dimensions: 1755 x 1040 x 30 mm (1.83 m²)"; recorded as length, width and depth in the printed order, in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, General Data, Dimensions row
A test load, printed as "Maximum test load (front): +7000 Pa (713 kg/m²)"; REC notes design load = test load / 1.5 (safety factor), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Maximum Ratings, Maximum test load (front) row
Printed in the 375 column of the STC table, row "Power Output - PMAX (Wp)" (375), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Electrical Data (STC), Power Output - PMAX (Wp) row, 375 column
Printed as "Max series fuse rating: 25 A", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Maximum Ratings, Max series fuse rating row
Printed as "Maximum system voltage: 1000 V", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Maximum Ratings, Maximum system voltage row
Printed in the 375 column of the STC table, row "Panel Efficiency (%)" (20.5), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Electrical Data (STC), Panel Efficiency (%) row, 375 column
Printed as "Operational temperature: -40 ... +85°C", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Maximum Ratings, Operational temperature row
Printed as "Temperature coefficient of PMAX: -0.34 %/°C"; REC notes the temperature coefficients stated are linear values, in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Temperature Ratings, PMAX row
Printed as "Temperature coefficient of ISC: 0.04 %/°C"; REC notes the temperature coefficients stated are linear values, in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Temperature Ratings, ISC row
Printed as "Temperature coefficient of VOC: -0.26 %/°C"; REC notes the temperature coefficients stated are linear values, in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Temperature Ratings, VOC row
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed in the 375 column of the STC table, row "Panel Efficiency (%)" (20.5), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The table prints values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 25°C). The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Read from the Standard column of the Warranty table, which prints "Product Warranty (yrs) 20 25 25" (Standard, REC ProTrust under 25 kW, REC ProTrust 25 to 500 kW), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Read from the Standard column of the Warranty table, which prints "Power Warranty (yrs) 25 25 25", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Power temperature coefficient-0.34 %/°C10.4 / 16.0
0.34 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature coefficient of PMAX: -0.34 %/°C"; REC notes the temperature coefficients stated are linear values, in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 61215-2:2016manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215-2:2016 Hailstone (35mm)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215:2016manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215:2016, IEC 61730:2016, UL 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61701 Salt Mist" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730:2016manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215:2016, IEC 61730:2016, UL 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 62716 Ammonia Resistance" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62782manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 62782 Dynamic Mechanical Load" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62804manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 62804 PID" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 61730manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
REC375TP4
Limitations
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215:2016, IEC 61730:2016, UL 61730" and "UL 61730 Fire Type Class 2" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 61730authority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
REC375TP4
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC375TP4": UL 61730, certifying entity not printed on the list, CEC listing date 2021-07-01. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
REC375TP4
Limitations
Model REC375TP4 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC375TP4", CEC listing date 2021-07-01. This is an equipment listing, not UL certification or complete-system approval.
Read from the Standard column of the Warranty table, which prints "Power in Year 25 86% 86% 86%", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Warranty table, Power in Year 25 row, Standard column
Read from the Standard column of the Warranty table, which prints "Product Warranty (yrs) 20 25 25" (Standard, REC ProTrust under 25 kW, REC ProTrust 25 to 500 kW), in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Warranty table, Product Warranty row, Standard column
Read from the Standard column of the Warranty table, which prints "Annual Degradation 0.5% 0.5% 0.5%", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Warranty table, Annual Degradation row, Standard column
Read from the Standard column of the Warranty table, which prints "Power Warranty (yrs) 25 25 25", in REC's Solar Panels Installation Manual (IEC edition, English, Rev 15 - 11.22), Technical Properties: REC TwinPeak 4 Series (product code RECxxxTP4), PDF page 23. The record was first read from REC's US datasheet edition, which is no longer on REC's site; this IEC edition of the manual prints the same figure. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: PDF page 23, REC TwinPeak 4 Series, Warranty table, Power Warranty row, Standard column
REC Group's own installation manual, captured September 28, 2026 with scripts/research/fetch.mjs from recgroup.com. UL 61730 edition. Its cover states installation instructions for all REC solar panels certified to IEC 61215 / UL 61730 and names REC TwinPeak 4 Series, REC TwinPeak 4 Black Series, REC N-Peak, N-Peak Black, N-Peak 2, N-Peak 2 Black and N-Peak 3 Black Series. It is a series-level manual: it establishes installation, handling, mounting and safety instructions for those series, not model-specific ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
IEC 61215:2016Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215:2016, IEC 61730:2016, UL 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730:2016Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215:2016, IEC 61730:2016, UL 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 61730Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215:2016, IEC 61730:2016, UL 61730" and "UL 61730 Fire Type Class 2" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62804Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 62804 PID" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61701 Salt Mist" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 62716 Ammonia Resistance" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62782Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 62782 Dynamic Mechanical Load" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215-2:2016Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21), Internet Archive copy of October 27, 2021 lists "IEC 61215-2:2016 Hailstone (35mm)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Electrical data at STC, temperature ratings, maximum ratings, mechanical data, general data, certification and warranty blocks
Retrieved Sep 24, 2026
Internet Archive copy, captured on October 27, 2021, of REC Group's own REC TwinPeak 4 Series datasheet (US edition, Ref: PM-DS-07-28 Rev- C 08.21) at https://www.recgroup.com/sites/default/files/documents/ds_rec_twinpeak_4_series_en_us.pdf; not a live manufacturer document. REC's current site, checked on September 25, 2026, no longer offers it: REC's product downloads index lists no datasheet for the series. Electrical figures are read from the STC table only; the NMOT table is not recorded.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC Group's own installation manual, captured September 28, 2026 with scripts/research/fetch.mjs from recgroup.com. IEC 61730 edition. Its cover states installation instructions for all REC solar panels certified to IEC 61215 / 61730 and names REC TwinPeak 4 Series, REC TwinPeak 4 Black Series, REC TwinPeak 5 Series, REC TwinPeak 5 Black Series and REC N-Peak 2 Series. It is a series-level manual: it establishes installation, handling, mounting and safety instructions for those series, not model-specific ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC TwinPeak 4 Series datasheet, US edition (Ref: PM-DS-07-28 Rev- C 08.21) (Internet Archive copy, October 27, 2021)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC Solar Panels Installation Manual (UL edition), Rev. 15, 11.22
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
REC375TP4
US market
Observed Oct 11, 2026
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC375TP4": UL 61730, certifying entity not printed on the list, CEC listing date 2021-07-01. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model REC375TP4 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC375TP4", CEC listing date 2021-07-01. This is an equipment listing, not UL certification or complete-system approval.