Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The table prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Panel Efficiency (%) 16.7 16.9 17.2 17.4".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Nominal Power Voltage - VMPP (V) 38.3 38.5 38.7 38.9".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Nominal Power Current - IMPP (A) 8.75 8.84 8.92 9.00".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Open Circuit Voltage - VOC (V) 46.2 46.3 46.5 46.7".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Short Circuit Current - ISC (A) 9.27 9.32 9.36 9.40".
Printed as "Temperature Coefficient of PMPP -0.36 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Printed as "Maximum System Voltage: 1000 V / 1500 V* *Dependent on product type" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet prints 1500 V for the variant whose product code carries the XV suffix; this record is the model without it, so 1000 V is recorded.
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The table prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Panel Efficiency (%) 16.7 16.9 17.2 17.4".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Nominal Power Voltage - VMPP (V) 38.3 38.5 38.7 38.9".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Nominal Power Current - IMPP (A) 8.75 8.84 8.92 9.00".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Open Circuit Voltage - VOC (V) 46.2 46.3 46.5 46.7".
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Short Circuit Current - ISC (A) 9.27 9.32 9.36 9.40".
Printed as "Temperature Coefficient of PMPP -0.36 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Printed as "Maximum System Voltage: 1000 V / 1500 V* *Dependent on product type" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet prints 1500 V for the variant whose product code carries the XV suffix; this record is the model without it, so 1000 V is recorded.
Cell description as printed ("Cell Type: 144 multicrystalline in 6 strings of 24 cells ") in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
A framed glass module: REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 prints "Glass: 0.13" (3.2 mm) solar glass with anti-reflection surface treatment" and "Frame: Anodized aluminum (silver) ".
Printed as "Glass: 0.13" (3.2 mm) solar glass with anti-reflection surface treatment" in REC Group's REC350TP2S 72 datasheet (REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)), captured on September 28, 2026.
Printed as "Cell Type: 144 multicrystalline in 6 strings of 24 cells " in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Printed as "Dimensions: 78.9 " x 39.4" x 1.2 " (2005 x 1001 x 30 mm)" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the metric figures are recorded.
Printed as "Weight: 48.5 lbs (22 kg)" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the metric figure is recorded.
Printed as "Max Series Fuse Rating: 20 A" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Printed as "Temperature Coefficient of ISC 0.066 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Printed as "Temperature Coefficient of VOC -0.30 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Location: Temperature ratings, Temperature coefficient of VOC
Documented
Published claims and calculations, not independent test results.
Documents
2 on file
PDF
REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)OfficialREC GroupOfficial datasheet
Certificate & compliance claims (6)
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "UL 1703, UL Fire Type 2, CEC listed" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62804Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist Corrosion Level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Location: Electrical data at STC, temperature ratings, maximum ratings, mechanical data, general data, certification and warranty blocks
Retrieved
Internet Archive copy, captured on May 17, 2017, of REC Group's own REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17) at https://www.recgroup.com/sites/default/files/documents/ds_rec_twinpeak_2s_72_series_rev_b_us.pdf; not a live manufacturer document. REC's current site, checked on September 25, 2026, no longer offers it: REC's product downloads index lists no datasheet for the series. Electrical figures are read from the STC table only; the NOCT table is not recorded.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
REC's current limited warranty conditions for REC TwinPeak panels, linked from REC's Product Downloads page (Warranty); valid as of October 1, 2018. Manufacturer terms, not an independent test.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
REC Warranty Conditions, REC TwinPeak, Rev D (Ref: PM2WARR27)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The product's datasheet printed a 10-year product warranty. REC's current TwinPeak warranty document, Rev D (captured October 17, 2026), states 20 years. Both are shown.
Printed as "10 year product warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the terms of the REC warranty document itself were not read.
20 years
REC's current warranty document, Rev D (captured October 17, 2026), states a product warranty "for a period of 20 years from the date of purchase by the Original End-User". The document applies to REC TwinPeak panels, including variants with the suffixes Black, BLK, BLK2, Mono and Q2, and is valid as of October 1, 2018.
The maximum annual degression, printed as "max. degression in performance of 0.7% p.a." in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Printed as "25 year linear power output warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the STC table, column 4 of 4 (350 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Panel Efficiency (%) 16.7 16.9 17.2 17.4".
10 years is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 30 years, the best documented for a solar panel, printed by the maker: AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module
Printed as "10 year product warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the terms of the REC warranty document itself were not read.
The maker's documents disagree; the less favorable printed figure, 10 years, is scored. Warning: REC's current warranty states different terms
Printed as "25 year linear power output warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
0.36 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature Coefficient of PMPP -0.36 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
UL 1703Product / system scope unresolvedClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "UL 1703, UL Fire Type 2, CEC listed" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. it describes the product as documented on that date.
IEC 61215Product / system scope unresolvedClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. it describes the product as documented on that date.
IEC 61730Product / system scope unresolvedClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. it describes the product as documented on that date.
IEC 62804Product / system scope unresolvedClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. it describes the product as documented on that date.
IEC 61701Product / system scope unresolvedClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist Corrosion Level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. it describes the product as documented on that date.
IEC 62716Product / system scope unresolvedClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. it describes the product as documented on that date.
UL 61730Product / system scope unresolvedClaimedListed when checked
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC350TP2S 72": UL 61730, certifying entity not printed on the list. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
CECProduct / system scope unresolvedClaimedListed when checked
Model REC350TP2S 72 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC350TP2S 72". This is an equipment listing, not UL certification or complete-system approval.
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "UL 1703, UL Fire Type 2, CEC listed" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62804Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist Corrosion Level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
REC350TP2S 72
US market
Observed
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC350TP2S 72": UL 61730, certifying entity not printed on the list. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model REC350TP2S 72 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC350TP2S 72". This is an equipment listing, not UL certification or complete-system approval.