Charged ReviewsSaved 0Compare 0Login
No photo yet
REC Group
Solar panel

REC Group REC335TP2S 72

Key specs

Rated power335 W
Weight22 kg / 49 lb converted
Open-circuit voltage46.2 V
Short-circuit current9.27 A
Voltage at max power38.3 V
Current at max power8.75 A

All specifications

Identity

BrandREC Group · Website
ModelREC335TP2S 72
MarketUS
Manufacturer SKUUnknown
SKU detail
conditions: REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 prints the product code and no separate part number.
Sources: No source on record
FieldValueConditionsSource
FrameAnodized aluminum (silver)
Printed in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: General data, Frame
[1]
Current at max power8.75 A
Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Nominal Power Current - IMPP (A) 8.75 8.84 8.92 9.00".
Where: Electrical data at STC, Nominal Power Current - IMPP row, column 1 of 4 (335 W)
[1]
Short-circuit current9.27 A
Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Short Circuit Current - ISC (A) 9.27 9.32 9.36 9.40".
Where: Electrical data at STC, Short Circuit Current - ISC row, column 1 of 4 (335 W)
[1]
Voltage at max power38.3 V
Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Nominal Power Voltage - VMPP (V) 38.3 38.5 38.7 38.9".
Where: Electrical data at STC, Nominal Power Voltage - VMPP row, column 1 of 4 (335 W)
[1]
Open-circuit voltage46.2 V
Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Open Circuit Voltage - VOC (V) 46.2 46.3 46.5 46.7".
Where: Electrical data at STC, Open Circuit Voltage - VOC row, column 1 of 4 (335 W)
[1]
Cell typemulticrystalline
Cell description as printed ("Cell Type: 144 multicrystalline in 6 strings of 24 cells ") in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: General data, Cell type
[1]
Weight22 kg / 49 lb converted
Printed as "Weight: 48.5 lbs (22 kg)" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the metric figure is recorded.
Where: Mechanical data, Weight
[1]
Cell count144 cells
Printed as "Cell Type: 144 multicrystalline in 6 strings of 24 cells " in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: General data, Cell type
[1]
ConnectorsTonglin TL-Cable01S-F, 12 AWG (4 mm²)
Printed in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: General data, Connectors
[1]
Front glass0.13" (3.2 mm) solar glass with anti-reflection surface treatment
Printed as "Glass: 0.13" (3.2 mm) solar glass with anti-reflection surface treatment" in REC Group's REC335TP2S 72 datasheet (REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Glass row
[1]
Junction boxIP67 rated with 3 bypass diodes
Printed in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: General data, Junction box
[1]
Panel formatrigid
A framed glass module: REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 prints "Glass: 0.13" (3.2 mm) solar glass with anti-reflection surface treatment" and "Frame: Anodized aluminum (silver) ".
Where: General data, Glass and Frame
[1]
Rear surfaceHighly resistant polyester
Printed as "Back Sheet: Highly resistant polyester" in REC Group's REC335TP2S 72 datasheet (REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Backsheet row
[1]
DimensionsW 1,001 × L 2,005 × D 30 mm / W 39.41 × L 78.94 × D 1.2 in converted
Printed as "Dimensions: 78.9 " x 39.4" x 1.2 " (2005 x 1001 x 30 mm)" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the metric figures are recorded.
Where: Mechanical data, Dimensions
[1]
Rated power335 W
Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The table prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350".
Where: Electrical data at STC, power row, column 1 of 4 (335 W)
[1]
Series fuse20 A
Printed as "Max Series Fuse Rating: 20 A" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Maximum ratings, Max series fuse rating
[1]
Max system voltage1,000 V
Printed as "Maximum System Voltage: 1000 V / 1500 V* *Dependent on product type" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet prints 1500 V for the variant whose product code carries the XV suffix; this record is the model without it, so 1000 V is recorded.
Where: Maximum ratings, Maximum system voltage
[1]
Module efficiency16.7 %
Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Panel Efficiency (%) 16.7 16.9 17.2 17.4".
Where: Electrical data at STC, Panel Efficiency row, column 1 of 4 (335 W)
[1]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "Operational Temperature: -40 ... +185°F (-40 ... +85°C)" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Maximum ratings, Operational temperature
[1]
Temperature coefficient-0.36 %/°C
Printed as "Temperature Coefficient of PMPP -0.36 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Temperature ratings, Temperature coefficient of PMPP
[1]
Isc temperature coefficient0.066 %/°C
Printed as "Temperature Coefficient of ISC 0.066 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Temperature ratings, Temperature coefficient of ISC
[1]
Voc temperature coefficient-0.3 %/°C
Printed as "Temperature Coefficient of VOC -0.30 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Temperature ratings, Temperature coefficient of VOC
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
335 WEfficiency 16.7 %W / sq ft 15.5* (Calculated: 335 W ÷ (2,005 mm × 1,001 mm = 21.6 sq ft) = 15.5 W/sq ft)
Voltage (STC)
38.3 VVmp · maximum powerVoc · open circuit 46.2 VMax system 1,000 V
Current (STC)
8.75 AImp · maximum powerIsc · short circuit 9.27 A
Dimensions
D: 30 × W: 1,001 × L: 2,005 mm / D: 1.2 × W: 39.41 × L: 78.94 inWeight 22 kg / 49 lb
Warranty
10 yearsPower warranty 25 years

Evidence score

50/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency16.7 %17.0 / 26.0

16.7 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the STC table, column 1 of 4 (335 W), of REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 77°F (25°C)". The header prints "Product Code*: RECxxxTP2S 72 Nominal Power - PMPP (Wp) 335 340 345 350" and the row prints "Panel Efficiency (%) 16.7 16.9 17.2 17.4".

[1]

Product warranty10 years7.0 / 21.0

10 years is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 30 years, the best documented for a solar panel, printed by the maker: AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "10 year product warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the terms of the REC warranty document itself were not read.

The maker's documents disagree; the less favorable printed figure, 10 years, is scored. Warning: REC's current warranty states different terms

[1]

Power warranty25 years13.3 / 16.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

Printed as "25 year linear power output warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.

[1]

Power temperature coefficient-0.36 %/°C9.8 / 16.0

0.36 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Printed as "Temperature Coefficient of PMPP -0.36 %/°C" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.

[1]

Weight / watt22 kg / 335 W3.3 / 5.0

0.06567 against 0.04308 kg per W, the lowest documented for a rigid solar panel (calculated from maker figures): EcoFlow 130W RVMax Rigid Solar Panel

22 kg / 335 W. Lighter modules per watt carry less roof load.

[1]

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 61215manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61701manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist Corrosion Level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61730manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62716manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62804manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "UL 1703, UL Fire Type 2, CEC listed" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 61730authority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC335TP2S 72": UL 61730, certifying entity not printed on the list. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[2]
CECauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
REC335TP2S 72
Limitations
Model REC335TP2S 72 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC335TP2S 72". This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[2]

Warranty

FieldValueConditionsSource
Warranty term10 years Check note
REC's current warranty states different terms. The product's datasheet printed a 10-year product warranty. REC's current TwinPeak warranty document, Rev D (captured October 17, 2026), states 20 years. Both are shown.
Printed as "10 year product warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017; the terms of the REC warranty document itself were not read.
Where: Warranty block
Sources
20 years

REC's current warranty document, Rev D (captured October 17, 2026), states a product warranty "for a period of 20 years from the date of purchase by the Original End-User". The document applies to REC TwinPeak panels, including variants with the suffixes Black, BLK, BLK2, Mono and Q2, and is valid as of October 1, 2018.

[3]
[1]
Annual degradation0.7 %
The maximum annual degression, printed as "max. degression in performance of 0.7% p.a." in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Warranty block
[1]
Performance warranty25 years
Printed as "25 year linear power output warranty" in REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017.
Where: Warranty block
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Datasheets

  • REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)Official · REC Group · Official datasheet · PDF
    Certificate & compliance claims (6)
    UL 1703Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "UL 1703, UL Fire Type 2, CEC listed" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
    IEC 61215Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
    IEC 61730Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61215, IEC 61730;" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
    IEC 62804Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
    IEC 61701Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 61701 (Salt Mist Corrosion Level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
    IEC 62716Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17), Internet Archive copy of May 17, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)
    Source details
    Revision
    Ref: NE-05-07-13 Rev-B 03.17
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Electrical data at STC, temperature ratings, maximum ratings, mechanical data, general data, certification and warranty blocks

    Retrieved Sep 24, 2026

    Internet Archive copy, captured on May 17, 2017, of REC Group's own REC TwinPeak 2S 72 Series datasheet (US edition, Ref: NE-05-07-13 Rev-B 03.17) at https://www.recgroup.com/sites/default/files/documents/ds_rec_twinpeak_2s_72_series_rev_b_us.pdf; not a live manufacturer document. REC's current site, checked on September 25, 2026, no longer offers it: REC's product downloads index lists no datasheet for the series. Electrical figures are read from the STC table only; the NOCT table is not recorded.

    Archived copies

    Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRef: NE-05-07-13 Rev-B 03.17 · 0.70 MB

    Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://web.archive.org/web/20170517132211id_/http://www.recgroup.com:80/sites/default/files/documents/ds_rec_twinpeak_2s_72_series_rev_b_us.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6d2de5848788133d3d261615d6b59d1b6b336d4c72b9f3f8c9f48725dc86ba0d

    Open
  • Warranty

  • REC Warranty Conditions, REC TwinPeak, Rev D (Ref: PM2WARR27)Official · REC Group · Official warranty · PDF
    Source details
    Revision
    Rev D
    Revision date
    Not stated

    Archived copy captured on 2026-10-17.

    Retrieved Oct 17, 2026

    REC's current limited warranty conditions for REC TwinPeak panels, linked from REC's Product Downloads page (Warranty); valid as of October 1, 2018. Manufacturer terms, not an independent test.

    Archived copies

    Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.20 MB

    Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/documents/warranty_tp_rev_d.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    25

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 58f4c977cdc82e3a702057c74652c57556cee406334a90ce16b4ec5034ae3599

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017)

Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRef: NE-05-07-13 Rev-B 03.17 · 0.70 MB

Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://web.archive.org/web/20170517132211id_/http://www.recgroup.com:80/sites/default/files/documents/ds_rec_twinpeak_2s_72_series_rev_b_us.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6d2de5848788133d3d261615d6b59d1b6b336d4c72b9f3f8c9f48725dc86ba0d

REC Warranty Conditions, REC TwinPeak, Rev D (Ref: PM2WARR27)

Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.20 MB

Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/documents/warranty_tp_rev_d.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
25

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 58f4c977cdc82e3a702057c74652c57556cee406334a90ce16b4ec5034ae3599

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
REC335TP2S 72

US market

  1. Observed Oct 11, 2026

    UL 61730: claimed

    Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC335TP2S 72": UL 61730, certifying entity not printed on the list. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.

    [2]

  2. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model REC335TP2S 72 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC335TP2S 72". This is an equipment listing, not UL certification or complete-system approval.

    [2]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 84
basis: Unknown
missing:
First-year degradation needed
criteria:
key: efficiency
label: Module efficiency
value: 16.7
unit: Unknown
shown: 16.7 %
shown detail: Unknown
state: documented
points: 17
ceiling: 26
weight: 26
share: 65.5
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: warranty
label: Product warranty
value: 10
unit: Unknown
shown: 10 years
shown detail: Unknown
state: documented
points: 7
ceiling: 21
weight: 21
share: 33.3
covered: yes
missing: no
folded: no
reason: documents-disagree
reason text: The maker's documents disagree; the less favorable printed figure, 10 years, is scored. Warning: REC's current warranty states different terms
note:
display note: Unknown
Sources: [1]
key: performanceWarranty
label: Power warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 13.3
ceiling: 16
weight: 16
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: powerTemperature
label: Power temperature coefficient
value: 0.36
unit: Unknown
shown: -0.36 %/°C
shown detail: Unknown
state: documented
points: 9.8
ceiling: 16
weight: 16
share: 61.1
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0657
unit: Unknown
shown: 22 kg / 335 W
shown detail: Unknown
state: documented
points: 3.3
ceiling: 5
weight: 5
share: 65.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 22 kg / 335 W. Lighter modules per watt carry less roof load.
display note: Unknown
Sources: [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. REC TwinPeak 2S 72 Series datasheet, US edition (Ref: NE-05-07-13 Rev-B 03.17) (Internet Archive copy, May 17, 2017) (REC Group · manufacturer · Ref: NE-05-07-13 Rev-B 03.17 · observed Sep 24, 2026)
  2. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
  3. REC Warranty Conditions, REC TwinPeak, Rev D (Ref: PM2WARR27) (REC Group · manufacturer · observed Oct 17, 2026)

Sign in to report an error on this page