conditions: REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 prints the product code and no separate part number.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Frame
Anodized aluminum (Available in silver or black)
Printed in REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019.
Printed as "Nominal Power Current - IMPP (a) 8.74 8.84 8.95 9.05 9.14 9.24" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Nominal Power Current - IMPP (a)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical characteristics, "Nominal Power Current - IMPP (a)" row, 300 column
REC documents differ: 9.82 A or 9.85 A. REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19) prints 9.82 A for this model; REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019) prints 9.85 A. Both are shown; the installation manual is listed first.
Printed as "Short Circuit Current - ISC (a) 9.52 9.61 9.66 9.71 9.76 9.82" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Short Circuit Current - ISC (a)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Revised on 1 October 2026: Owner source order puts the installation manual first: REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19) prints 9.82 A for this model; the earlier value 9.85 A came from REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019) and is kept beside it.
Where: PDF page 16, technical characteristics, "Short Circuit Current - ISC (a)" row, 300 column
Sources
9.85 A
Read from the STC table, column 6 of 6 (300 W), of REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "Product Code*: RECxxxTP2 Nominal Power - PMPP (Wp) 275 280 285 290 295 300" and the row prints "Short Circuit Current - ISC (A) 9.59 9.64 9.69 9.75 9.80 9.85".
Printed as "Nominal Power Voltage - VMPP (V) 31.5 31.7 31.9 32.1 32.3 32.5" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Nominal Power Voltage - VMPP (V)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical characteristics, "Nominal Power Voltage - VMPP (V)" row, 300 column
REC documents differ: 39.2 V or 39.1 V. REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19) prints 39.2 V for this model; REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019) prints 39.1 V. Both are shown; the installation manual is listed first.
Printed as "Open Circuit Voltage - VOC (V) 38.2 38.4 38.6 38.8 39.0 39.2" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Open Circuit Voltage - VOC (V)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Revised on 1 October 2026: Owner source order puts the installation manual first: REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19) prints 39.2 V for this model; the earlier value 39.1 V came from REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019) and is kept beside it.
Where: PDF page 16, technical characteristics, "Open Circuit Voltage - VOC (V)" row, 300 column
Sources
39.1 V
Read from the STC table, column 6 of 6 (300 W), of REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "Product Code*: RECxxxTP2 Nominal Power - PMPP (Wp) 275 280 285 290 295 300" and the row prints "Open Circuit Voltage - VOC (V) 37.9 38.2 38.4 38.6 38.9 39.1".
Printed as "Nominal operating cell temperature (NOCT) 44.6°C (±2°C)" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Temperature Ratings. Printed with a tolerance of ±2°C.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Temperature Ratings
Cell description as printed ("Cell type: 6 strings of 20 REC HC multicrystalline PERC ") in REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019.
Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440).; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²).; Attach grounds to the grounding holes in the panel frames.; Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection (fig. 10).
Printed as "Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440)." in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), Grounding section (bulleted instructions) and Fig. 13. Fig. 13 prints the wire fastening torque for the GBL-4DBT lug by wire size (4 - 6 AWG stranded 35 in-lbs, 8 AWG stranded 25 in-lbs, 10 - 14 AWG 2.8 in-lbs, as printed). The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 11, Grounding section (bulleted instructions) and Fig. 13
Printed as "Weight: 40.8 lbs (18.5 kg)" in REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019; the metric figure is recorded.
0.13" (3.2 mm) solar glass with anti-reflective surface treatment
Printed as "Glass: 0.13" (3.2 mm) solar glass with anti-reflective surface treatment" in REC Group's REC300TP2 datasheet (REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019)), captured on September 28, 2026.
A framed glass module: REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 prints "Glass: 0.13" (3.2 mm) solar glass with anti-reflective surface treatment" and "Frame: Anodized aluminum (Available in silver or black) ".
Highly resistant polyester polyolefin construction
Printed as "Back sheet: Highly resistant polyester polyolefin construction" in REC Group's REC300TP2 datasheet (REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Backsheet row
W 997 × L 1,675 × D 38 mm / W 39.3 × L 65.94 × D 1.5 in converted
Printed as "Dimensions: 65.9 x 39.25 x 1.5 (1675 x 997 x 38 mm)" in REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019; the metric figures are recorded.
Printed as "Nominal Power - PMPP (Wp) 275 280 285 290 295 300" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Nominal Power - PMPP (Wp)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical characteristics, "Nominal Power - PMPP (Wp)" row, 300 column
Printed as "Max series fuse rating: 20 A" in REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019.
Clamps in the green zone: 8.2-16.4 in (208-416 mm) are certified for downward loads of 112 psf (DL: 3600 Pa) & upward loads of 50 psf (DL :1600 Pa); Clamps in the yellow zone: 0-8.2 in (0-208 mm) long side; 0-9.8 in (0 -250 mm) short side, are certified for downward & upward loads of 50 psf (DL :1600 Pa); Clamping in the red zone is not permitted (> 16.4 in (416 mm) on long side, > 9.8 in (250 mm) on short side), where only four clamping points are used; REC solar panels can be mounted utilizing the four 0,43 x 0,26 in (11 x 6.6 mm) elongated holes on the underside of the panel at a distance of 15 in (382.5 mm) from the corner; Mounting in this way has been found to be in compliance with UL 1703 requirements for test loads of up to 112 psf (5400 Pa, or a design load of 3600 Pa*) downward force and 50 psf (2400 Pa, or a design load of 1600 Pa*) upwards force
Printed as "Clamps in the green zone: 8.2-16.4 in (208-416 mm) are certified for downward loads of 112 psf (DL: 3600 Pa) & upward loads of 50 psf (DL :1600 Pa)" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), Mounting methods for the REC TwinPeak 2, REC TwinPeak 2 BLK, REC TwinPeak 2 BLK2 & REC TwinPeak 2 Mono panels (clamping zones, Fig. 8) and PDF page 10 (Mounting methods: Mounting holes). The first three lines are the clamping zones the manual prints for the REC TwinPeak 2, REC TwinPeak 2 BLK, REC TwinPeak 2 BLK2 & REC TwinPeak 2 Mono panels (clamps on rails, at least four points in four separate zones; DL is design load, with a safety factor of 1.5 on the test load), the last two the mounting-hole method from PDF page 10. The manual also permits slide-in systems meeting the same grip specifications, noting they were not tested to UL 1703 with REC panels.
Where: PDF page 9, Mounting methods for the REC TwinPeak 2, REC TwinPeak 2 BLK, REC TwinPeak 2 BLK2 & REC TwinPeak 2 Mono panels (clamping zones, Fig. 8) and PDF page 10 (Mounting methods: Mounting holes)
The cables on REC solar panels have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 15).
Printed as "The cables on REC solar panels have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 15)." in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), Connections and Connectors, Protecting the cables. A series-wide instruction for every panel this manual covers.
Where: PDF page 12, Connections and Connectors, Protecting the cables
Printed as "Max series fuse rating: 20 a" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Maximum Ratings. One figure for the whole series. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Maximum Ratings
Printed as "Maximum system voltage: 1000 V" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Maximum Ratings. One figure for the whole series. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Maximum Ratings
Printed as "Panel Efficiency (%) 16.5 16.8 17.1 17.4 17.7 18.0" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Panel Efficiency (%)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Printed as "Operational temperature: -40 ... +185°F (-40 ... +85°C)" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Temperature Ratings. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Temperature Ratings
Printed as "Temperature coefficient of PMPP -0.36 %/°C" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Temperature Ratings. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Temperature Ratings
Printed as "Temperature coefficient of ISC 0.066 %/°C" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Temperature Ratings. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Temperature Ratings
Printed as "Temperature coefficient of VOC -0.30 %/°C" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Temperature Ratings. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 16, technical properties of the REC TwinPeak 2 Series, Temperature Ratings
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "Panel Efficiency (%) 16.5 16.8 17.1 17.4 17.7 18.0" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical characteristics, "Panel Efficiency (%)" row, 300 column. Column 6 of 6 in the row, the 300 column of the table headed "Product Code*: RECxxxTP2". The text layer stores capital letters of this typeface as lowercase in places, for example the unit (A) as "(a)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
REC's Limited Warranty Certificate for REC TwinPeak solar panels (REC Warranty Conditions, REC TwinPeak Rev D, valid as of October 1, 2018), which covers REC TwinPeak panels including variants with the suffixes Black, BLK, BLK2, Mono and Q2 (excluding Q3), North, Central and South America section prints a product warranty "for a period of 20 years from the date of purchase by the Original End-User". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
REC's Limited Warranty Certificate for REC TwinPeak solar panels (REC Warranty Conditions, REC TwinPeak Rev D, valid as of October 1, 2018), which covers REC TwinPeak panels including variants with the suffixes Black, BLK, BLK2, Mono and Q2 (excluding Q3), North, Central and South America section prints a performance warranty to "the end of the 25th year, an actual output of at least 80.7%" of nameplate power. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
0.36 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature coefficient of PMPP -0.36 %/°C" in REC's 60-cell panels installation manual (UL 1703 edition, Rev C.2 - 01.19), technical properties of the REC TwinPeak 2 Series, Temperature Ratings. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 60068-2-68manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 60068-2-68 (Blowing Sand)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 61215, IEC 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 61701 (Salt Mist level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 61215, IEC 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 62716 (Ammonia)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62804manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
ISO 11925-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "ISO 11925-2 (Class E)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC300TP2
Limitations
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "UL 1703, Fire classification Type 2" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
UL 61730authority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
REC300TP2
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC300TP2": UL 61730, certifying entity not printed on the list. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
REC300TP2
Limitations
Model REC300TP2 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC300TP2". This is an equipment listing, not UL certification or complete-system approval.
REC's Limited Warranty Certificate for REC TwinPeak solar panels (REC Warranty Conditions, REC TwinPeak Rev D, valid as of October 1, 2018), which covers REC TwinPeak panels including variants with the suffixes Black, BLK, BLK2, Mono and Q2 (excluding Q3), North, Central and South America section prints a product warranty "for a period of 20 years from the date of purchase by the Original End-User". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: North, Central and South America section, I. Product Warranty
REC's Limited Warranty Certificate for REC TwinPeak solar panels (REC Warranty Conditions, REC TwinPeak Rev D, valid as of October 1, 2018), which covers REC TwinPeak panels including variants with the suffixes Black, BLK, BLK2, Mono and Q2 (excluding Q3), North, Central and South America section prints that the actual power output "will decline annually by no more than 0.7% for a period of 24 years" (the TwinPeak 4 and 5 terms are printed separately). Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: North, Central and South America section, II. Power Output Warranty
REC's Limited Warranty Certificate for REC TwinPeak solar panels (REC Warranty Conditions, REC TwinPeak Rev D, valid as of October 1, 2018), which covers REC TwinPeak panels including variants with the suffixes Black, BLK, BLK2, Mono and Q2 (excluding Q3), North, Central and South America section prints a performance warranty to "the end of the 25th year, an actual output of at least 80.7%" of nameplate power. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: North, Central and South America section, II. Power Output Warranty
Location: Cover page (scope) and PDF page 2 (revision)
Retrieved Oct 1, 2026
REC's own installation manual for its 60-cell panels certified to UL 1703, printed as Rev C.2 - 01.19 (Ref: NE-06-22). REC no longer publishes it; captured 1 October 2026 as the Internet Archive copy of April 24, 2019 of the file recgroup.com then served. Its cover names the REC Peak Energy and Peak Energy BLK, TwinPeak and TwinPeak BLK, TwinPeak 2 and TwinPeak 2 BLK, TwinPeak 2 BLK2 and TwinPeak 2 Mono series, and its Panel Characteristics section prints a technical sheet for the Peak Energy, TwinPeak, TwinPeak 2, TwinPeak 2 BLK2 and TwinPeak 2 Mono series. Later revisions of REC's combined manual that still named these series are not available as complete copies. Series-level instructions and the technical sheets as printed; manufacturer instructions, not independent tests.
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "UL 1703, Fire classification Type 2" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61215Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 61215, IEC 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61730Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 61215, IEC 61730" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62804Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 62716Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 62716 (Ammonia)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 61701Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 61701 (Salt Mist level 6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
IEC 60068-2-68Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "IEC 60068-2-68 (Blowing Sand)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
ISO 11925-2Manufacturer claim · equipment listingClaimedListed when checked
REC Group's REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19), Internet Archive copy of October 15, 2019 lists "ISO 11925-2 (Class E)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Electrical data at STC, temperature ratings, maximum ratings, mechanical data, general data, certification and warranty blocks
Retrieved Sep 24, 2026
Internet Archive copy, captured on October 15, 2019, of REC Group's own REC TwinPeak 2 Series datasheet (UL edition, Ref: PM-DS-07-07 Rev- I 07.19) at https://www.recgroup.com/sites/default/files/documents/ds_rec_twinpeak_2_series_ul_rev_i_en_web.pdf; not a live manufacturer document. REC's current site, checked on September 25, 2026, no longer offers it: REC's product downloads index lists no datasheet for the series. Electrical figures are read from the STC table only; the NOCT table is not recorded.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC's current limited warranty conditions for REC TwinPeak panels, linked from REC's Product Downloads page (Warranty); valid as of October 1, 2018. Manufacturer terms, not an independent test.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
REC TwinPeak 2 Series datasheet, UL edition (Ref: PM-DS-07-07 Rev- I 07.19) (Internet Archive copy, October 15, 2019)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
REC Warranty Conditions, REC TwinPeak, Rev D (Ref: PM2WARR27)
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
REC300TP2
US market
Observed Oct 11, 2026
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC300TP2": UL 61730, certifying entity not printed on the list. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model REC300TP2 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC300TP2". This is an equipment listing, not UL certification or complete-system approval.