Charged ReviewsSaved 0Compare 0Login
No photo yet
REC Group
Solar panel

REC Group REC270PE

Key specs

Rated power270 W
Weight18 kg / 40 lb converted
Open-circuit voltage38.4 V
Short-circuit current9.18 A
Voltage at max power31.3 V Check note
Current at max power8.66 A

All specifications

Identity

BrandREC Group · Website
ModelREC270PE
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 prints the product code and no separate part number.
Sources: No source on record
FieldValueConditionsSource
FrameAnodized aluminum (Available in silver or black color)
Printed in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: General data, Frame
[1]
Current at max power8.66 A
Printed as "nominal Power Current - IMPP (a) 8.06 8.17 8.23 8.30 8.42 8.50 8.58 8.66" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "nominal Power Current - IMPP (a)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, "nominal Power Current - IMPP (a)" row, 270 column
[2] [1]
Short-circuit current9.18 A
Printed as "short Circuit Current - IsC(a) 8.66 8.75 8.80 8.86 8.95 9.01 9.08 9.18" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "short Circuit Current - IsC(a)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, "short Circuit Current - IsC(a)" row, 270 column
[2] [1]
Voltage at max power31.3 V Check note
REC documents differ: 31.3 V or 31.2 V. REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15) prints 31.3 V for this model; REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017) prints 31.2 V. Both are shown; the installation manual is listed first.
Printed as "nominal Power voltage - vMPP (v) 29.5 29.7 30.1 30.2 30.5 30.7 30.9 31.3" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "nominal Power voltage - vMPP (v)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Revised on 1 October 2026: Owner source order puts the installation manual first: REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15) prints 31.3 V for this model; the earlier value 31.2 V came from REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017) and is kept beside it.
Where: PDF page 11, technical characteristics, "nominal Power voltage - vMPP (v)" row, 270 column
Sources
31.2 V

Read from the STC table, column 6 of 6 (270 W), of REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017. The sheet states "Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m², cell temperature 25°C)". The header prints "Product Code*: RECxxxPE Nominal Power - PMPP (Wp) 245 250 255 260 265 270" and the row prints "Nominal Power Voltage - VMPP (V) 30.1 30.2 30.5 30.7 30.9 31.2".

[1]
[2]
Open-circuit voltage38.4 V
Printed as "open Circuit voltage - voC (v) 36.6 36.8 37.1 37.4 37.6 37.8 38.1 38.4" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "open Circuit voltage - voC (v)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, "open Circuit voltage - voC (v)" row, 270 column
[2] [1]
Cell typemulti-crystalline
Cell description as printed ("Cell type: 60 multi-crystalline 3 strings of 20 cells with 3 bypass diodes ") in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: General data, Cell type
[1]
GroundingSuitable grounding lugs must be used.; Grounding cable size should be between 2.1 mm² - 21.2 mm².; Fix lug to the frame using a star washer and lock nut, ensuring a conductive connection (fig. 8).; Place the star washer between the frame and the nut, using a 5 mm diameter stainless steel bolt and locking nut to mount the lug to the panel frame and tighten according to the manufacturer’s recommended torque.
Printed as "suitable grounding lugs must be used." in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), section vii) Grounding. Where grounding is necessary. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 8, section vii) Grounding
[2]
Weight18 kg / 40 lb converted
Printed as "Weight: 18 kg" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017; the metric figure is recorded.
Where: Mechanical data, Weight
[1]
Cell count60 cells
Printed as "Cell type: 60 multi-crystalline 3 strings of 20 cells with 3 bypass diodes " in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: General data, Cell type
[1]
ConnectorsStäubli MC4 PV-KBT4/PV-KST4 (4 mm²) Tonglin TL-Cable01SFR (4 mm²) *dependent on product type
Printed in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: General data, Connectors
[1]
Front glass3.2 mm solar glass with anti-reflection surface treatment
Printed as "Glass: 3.2 mm solar glass with anti-reflection surface treatment" in REC Group's REC270PE datasheet (REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Glass row
[1]
Junction boxIP67 rated
Printed in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: General data, Junction box
[1]
Panel formatrigid
A framed glass module: REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 prints "Glass: 3.2 mm solar glass with anti-reflection surface treatment" and "Frame: Anodized aluminum (Available in silver or black color) ".
Where: General data, Glass and Frame
[1]
Rear load pa2,400 Pa
Printed as "Maximum wind load: 244 kg/m² (2400 Pa)" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017; recorded as the rear (uplift) load. The sheet does not say whether this is a test or a design load.
Where: Maximum ratings, Maximum wind load
[1]
Rear surfaceHighly resistant polyester
Printed as "Back sheet: Highly resistant polyester" in REC Group's REC270PE datasheet (REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)), captured on September 28, 2026.
Where: Datasheet page 2, GENERAL DATA, Backsheet row
[1]
DimensionsW 991 × L 1,665 × D 38 mm / W 39 × L 65.55 × D 1.5 in converted
Printed as "Dimensions: 1665 x 991 x 38 mm" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017; the metric figures are recorded.
Where: Mechanical data, Dimensions
[1]
Front load pa5,400 Pa
Printed as "Maximum snow load: 550 kg/m² (5400 Pa)" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017; recorded as the front (downward) load. The sheet does not say whether this is a test or a design load.
Where: Maximum ratings, Maximum snow load
[1]
Rated power270 W
Printed as "nominal Power - PMPP (wp) 235 240 245 250 255 260 265 270" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "nominal Power - PMPP (wp)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, "nominal Power - PMPP (wp)" row, 270 column
[2] [1]
Series fuse25 A
Printed as "Max series fuse rating: 25 A" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: Maximum ratings, Max series fuse rating
[1]
Mounting methodsClamping within the green zone (208 - 416 mm) is certified for design loads up to 5400 Pa (550 kg/m²); Clamping within the yellow zone (0 - 208 mm long side, 250 mm short side) is certifed for design loads up to 2400 Pa (244 kg/m²); Clamping within the red zone is not permitted (> 416 mm long side, > 250 mm short side) when only using four clamps; REC Peak Energy panels can also be secured to the mounting structure using the mounting holes (fig. 5) found on the underside of the frame (6.6 x 11 mm, spaced 450 mm from the midpoint of the long side).
Printed as "Clamping within the green zone (208 - 416 mm) is certified for design loads up to 5400 Pa (550 kg/m²)" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), Clamp mounting positions (Fig. 4) and Mounting holes. The panels can be fixed on both the long and the short side within the zones of Fig. 4 with a minimum of four clamps ("certifed" is as printed); slide-in systems meeting the same grip specifications are also permitted.
Where: PDF page 7, Clamp mounting positions (Fig. 4) and Mounting holes
[2]
Cable bend radiusThe cables on REC Peak Energy panels have a minimum bending radius of 30 mm to avoid damage to the insulation (Fig. 9).
Printed as "the cables on REC Peak Energy panels have a minimum bending radius of 30 mm to avoid damage to the insulation (Fig. 9)." in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), Connections and connectors, Protecting the cables. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 8, Connections and connectors, Protecting the cables
[2]
Max series fuse25 A
Printed as "Max series Fuse Rating 25 a" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, Maximum Ratings. One figure for the series (IEC edition); the string configuration instructions on PDF page 4 print the same 25 A. The UL 1703 edition of REC's 60-cell manual (Rev C.2 - 01.19) prints 15 A for the Peak Energy Series. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page.
Where: PDF page 11, technical characteristics, Maximum Ratings
[2]
Max system voltage1,000 V
Printed as "Maximum system voltage 1000 v" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, Maximum Ratings. One figure for the series. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, Maximum Ratings
[2] [1]
Module efficiency16.4 %
Printed as "Panel Efficiency (%) 14.2 14.5 14.8 15.1 15.5 15.8 16.1 16.4" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "Panel Efficiency (%)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, "Panel Efficiency (%)" row, 270 column
[2] [1]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "operational temperature -40 ... +85°C" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, Maximum Ratings. The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, technical characteristics, Maximum Ratings
[2] [1]
Temperature coefficient-0.4 %/°C
Printed as "Temperature coefficient of PMPP -0.40 %/°C" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: Temperature ratings, Temperature coefficient of PMPP
[1]
Isc temperature coefficient0.024 %/°C
Printed as "Temperature coefficient of ISC 0.024 %/°C" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: Temperature ratings, Temperature coefficient of ISC
[1]
Voc temperature coefficient-0.27 %/°C
Printed as "Temperature coefficient of VOC -0.27 %/°C" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.
Where: Temperature ratings, Temperature coefficient of VOC
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
270 WEfficiency 16.4 %W / sq ft 15.2* (Calculated: 270 W ÷ (1,665 mm × 991 mm = 17.76 sq ft) = 15.2 W/sq ft)
Voltage (STC)
31.3 VNeeds confirmationVmp · maximum powerVoc · open circuit 38.4 VMax system 1,000 V
Current (STC)
8.66 AImp · maximum powerIsc · short circuit 9.18 A
Dimensions
D: 38 × W: 991 × L: 1,665 mm / D: 1.5 × W: 39 × L: 65.55 inWeight 18 kg / 40 lb
Warranty
10 yearsPower warranty 25 years

Evidence score

49/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency16.4 %16.7 / 26.0

16.4 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Printed as "Panel Efficiency (%) 14.2 14.5 14.8 15.1 15.5 15.8 16.1 16.4" in REC's Peak Energy Series installation manual (IEC 61215/61730 edition, Rev M - 06.15), technical characteristics, "Panel Efficiency (%)" row, 270 column. Column 8 of 8 in the row, the 270 column of the table headed "ELECTRICAL DATA @ STC". The PDF's text layer stores some capital letters of this manual's typeface as lowercase; the wording here follows the printed page. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to REC Group (web.archive.org), which stays listed as an additional source.

[2] [1]

Product warranty10 years7.0 / 21.0

10 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a product warranty "for a period of ten (10) years from the date of purchase by the Original End-User". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).

[3]

Power warranty25 years13.3 / 16.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a power output warranty to "the end of the 25th year, an actual output of at least 80.2%" of nameplate power. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).

[3]

Power temperature coefficient-0.4 %/°C8.8 / 16.0

0.4 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Printed as "Temperature coefficient of PMPP -0.40 %/°C" in REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017.

[1]

Weight / watt18 kg / 270 W3.2 / 5.0

0.06667 against 0.04308 kg per W, the lowest documented for a rigid solar panel (calculated from maker figures): EcoFlow 130W RVMax Rigid Solar Panel

18 kg / 270 W. Lighter modules per watt carry less roof load.

[1] [2]

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 60068-2-68manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 60068-2-68 (Blowing Sand)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61215manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61701manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61701(SaltMistlevel6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61730manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62716manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62804manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
ISO11925-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "ISO11925-2 (Class E)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
MCSmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" and "CERTIFICATE BBA 0044 MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UNI8457/9174manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
REC270PE
Limitations
REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "UNI8457/9174 (Class A)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term10 years
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a product warranty "for a period of ten (10) years from the date of purchase by the Original End-User". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: English sections, I. Product Warranty
[3]
Annual degradation0.7 %
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints that the actual power output "will decline annually by no more than 0.7% for a period of 24 years". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: English sections, II. Power Output Warranty
[3]
Performance warranty25 years
REC's Limited Warranty Certificate for REC Peak Energy panels (REC Warranty Conditions, REC Peak Energy Products Rev L, valid as of January 1, 2017), which covers all panels with the REC Peak Energy name (excluding panels showing Q3) prints a power output warranty to "the end of the 25th year, an actual output of at least 80.2%" of nameplate power. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; REC's own live document prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: English sections, II. Power Output Warranty
[3]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • REC Installation Manual, REC 60-Cell Panels (UL 1703 edition, Rev C.2, 01.19), Internet Archive copy of April 24, 2019REC Group · Source installation manual · January 2019 · PDF
    Source details
    Revision
    Rev C.2
    Revision date
    January 2019

    Archived copy captured on 2026-10-01.

    Location: Cover page (scope) and PDF page 2 (revision)

    Retrieved Oct 1, 2026

    REC's own installation manual for its 60-cell panels certified to UL 1703, printed as Rev C.2 - 01.19 (Ref: NE-06-22). REC no longer publishes it; captured 1 October 2026 as the Internet Archive copy of April 24, 2019 of the file recgroup.com then served. Its cover names the REC Peak Energy and Peak Energy BLK, TwinPeak and TwinPeak BLK, TwinPeak 2 and TwinPeak 2 BLK, TwinPeak 2 BLK2 and TwinPeak 2 Mono series, and its Panel Characteristics section prints a technical sheet for the Peak Energy, TwinPeak, TwinPeak 2, TwinPeak 2 BLK2 and TwinPeak 2 Mono series. Later revisions of REC's combined manual that still named these series are not available as complete copies. Series-level instructions and the technical sheets as printed; manufacturer instructions, not independent tests.

    Open
  • Datasheets

  • REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)Official · REC Group · Official datasheet · PDF
    Certificate & compliance claims (10)
    IEC 61215Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    IEC 61730Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    UL 1703Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    MCSManufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61215, IEC 61730 & UL 1703; MCS" and "CERTIFICATE BBA 0044 MCS" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    IEC 62804Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 62804 (PID)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    IEC 62716Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 62716 (Ammonia Resistance)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    IEC 60068-2-68Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 60068-2-68 (Blowing Sand)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    IEC 61701Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "IEC 61701(SaltMistlevel6)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    UNI8457/9174Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "UNI8457/9174 (Class A)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    ISO11925-2Manufacturer claim · equipment listingClaimedListed when checked

    REC Group's REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17), Internet Archive copy of March 29, 2017 lists "ISO11925-2 (Class E)" for the series. Recorded as the manufacturer printed it; read on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified; it describes the product as documented on that date.

    Manufacturer document

    Official datasheet: REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)
    Source details
    Revision
    Ref: NE-05-05-01-X 02.17
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Electrical data at STC, temperature ratings, maximum ratings, mechanical data, general data, certification and warranty blocks

    Retrieved Sep 24, 2026

    Internet Archive copy, captured on March 29, 2017, of REC Group's own REC Peak Energy Series datasheet (international edition, Ref: NE-05-05-01-X 02.17) at https://www.recgroup.com/sites/default/files/documents/ds_rec_peak_energy_series_rev_x_eng.pdf; not a live manufacturer document. REC's current site, checked on September 25, 2026, no longer offers it: REC's product downloads index lists no datasheet for the series. Electrical figures are read from the STC table only; the NOCT table is not recorded.

    Archived copies

    Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRef: NE-05-05-01-X 02.17 · 0.75 MB

    Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://web.archive.org/web/20170329094104id_/http://www.recgroup.com:80/sites/default/files/documents/ds_rec_peak_energy_series_rev_x_eng.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: a509ff90ecb746bf2bdf77634d334d6fd5f12ef07382eb5104f9e5471ed730af

    Open
  • Warranty

  • REC Warranty Conditions, REC Peak Energy Products, Rev L (Ref: NE259231231)Official · REC Group · Official warranty · PDF
    Source details
    Revision
    Rev L
    Revision date
    Not stated

    Archived copy captured on 2026-10-17.

    Retrieved Oct 17, 2026

    REC's current limited warranty conditions for REC Peak Energy panels, linked from REC's Product Downloads page (Warranty); valid as of January 1, 2017. Manufacturer terms, not an independent test.

    Archived copies

    Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.50 MB

    Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/documents/warranty_rec_peak_energy_rev_l_web.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    21

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 51bd1370bf33a3179c63adc4a2a4f5f664c28c1254e1a6c8df4567f0a6a6a54f

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • REC Installation Manual, REC Peak Energy Series (IEC 61215/61730 edition, Rev M, 06.15), Internet Archive copy of May 28, 2016REC Group · Source installation manual · June 2015 · PDF
    Source details
    Revision
    Rev M
    Revision date
    June 2015

    Archived copy captured on 2026-10-01.

    Location: Cover page and PDF page 3 (How to use this manual)

    Retrieved Oct 1, 2026

    REC's own installation manual for its Peak Energy Series panels certified to IEC 61215 / 61730, printed as Rev M - 06.15 (Ref: NE-06-03-M). REC no longer publishes it; captured 1 October 2026 as the Internet Archive copy of May 28, 2016 of the file recgroup.com then served. It covers all REC Peak Energy panels including variants with a black backsheet and/or a black frame, excluding 72-cell panels, and prints one technical sheet (235 to 270 Wp) for the series. Series-level instructions; manufacturer instructions, not independent tests.

    Open

Archived documents

REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017)

Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRef: NE-05-05-01-X 02.17 · 0.75 MB

Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://web.archive.org/web/20170329094104id_/http://www.recgroup.com:80/sites/default/files/documents/ds_rec_peak_energy_series_rev_x_eng.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a509ff90ecb746bf2bdf77634d334d6fd5f12ef07382eb5104f9e5471ed730af

REC Warranty Conditions, REC Peak Energy Products, Rev L (Ref: NE259231231)

Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.50 MB

Archived copy, unaltered, kept as a record of what REC Group published. Original address: https://www.recgroup.com/sites/default/files/documents/warranty_rec_peak_energy_rev_l_web.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
21

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 51bd1370bf33a3179c63adc4a2a4f5f664c28c1254e1a6c8df4567f0a6a6a54f

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
REC270PE

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 84
basis: Unknown
missing:
First-year degradation needed
criteria:
key: efficiency
label: Module efficiency
value: 16.4
unit: Unknown
shown: 16.4 %
shown detail: Unknown
state: documented
points: 16.7
ceiling: 26
weight: 26
share: 64.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: warranty
label: Product warranty
value: 10
unit: Unknown
shown: 10 years
shown detail: Unknown
state: documented
points: 7
ceiling: 21
weight: 21
share: 33.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [3]
key: performanceWarranty
label: Power warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 13.3
ceiling: 16
weight: 16
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [3]
key: powerTemperature
label: Power temperature coefficient
value: 0.4
unit: Unknown
shown: -0.4 %/°C
shown detail: Unknown
state: documented
points: 8.8
ceiling: 16
weight: 16
share: 55
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0667
unit: Unknown
shown: 18 kg / 270 W
shown detail: Unknown
state: documented
points: 3.2
ceiling: 5
weight: 5
share: 64.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 18 kg / 270 W. Lighter modules per watt carry less roof load.
display note: Unknown
Sources: [1] [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. REC Peak Energy Series datasheet, international edition (Ref: NE-05-05-01-X 02.17) (Internet Archive copy, March 29, 2017) (REC Group · manufacturer · Ref: NE-05-05-01-X 02.17 · observed Sep 24, 2026)
  2. REC Installation Manual, REC Peak Energy Series (IEC 61215/61730 edition, Rev M, 06.15), Internet Archive copy of May 28, 2016 (REC Group · archive · Rev M · observed Oct 1, 2026)
  3. REC Warranty Conditions, REC Peak Energy Products, Rev L (Ref: NE259231231) (REC Group · manufacturer · observed Oct 17, 2026)

Sign in to report an error on this page