Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Nominal Power Current - IMPP(A) 8.29 8.38 8.49". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "470", row beginning "Nominal Power Current -"
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Short Circuit Current - ISC (A) 8.81 8.88 8.95". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "470", row beginning "Short Circuit Current -"
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Nominal Power Voltage - VMPP(V) 54.3 54.9 55.4". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "470", row beginning "Nominal Power Voltage -"
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Open Circuit Voltage - VOC (V) 65.6 65.7 65.7". Under STC (1000 W/m², 25°C, AM 1.5), front side. REC prints the same electrical columns in its US Pure-RX datasheet and its domestic-content Pure-RX-DC datasheet, so the -DC and the plain model carry identical figures. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "470", row beginning "Open Circuit Voltage -"
Datasheet prints "Cell Type 88 half-cut bifacial REC heterojunction cells, with gapless technology". Covers product code RECXXXAA PURE-RX-DC in the 450-470 W classes, which includes this model.
Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440),; Grounding cable size should be between 4 - 14 AWG (2.1 mm² - 21.2 mm²),; Attach grounds to the grounding holes in the panel frames,Fix lug to the frame using a star washer (#10) and lock nut (#10), ensuring a conductive connection
Printed as "Suitable grounding lugs must be used: Listed (KDER) ILSCO, GBL-4DBT (tin plated) (E34440)," in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Grounding section (bulleted instructions) and Fig. 1-6. Fig. 1-6 prints the wire fastening torque for the lug by wire size.
Where: PDF page 11, Grounding section (bulleted instructions) and Fig. 1-6
Printed as "Weight 50.0 lb / 22.7 kg" in REC Alpha Pure-RX domestic-content datasheet (UL), Datasheet, general data table, Weight row. Revised on 1 October 2026: The REC datasheet prints "50.0 lb / 22.7 kg" for every watt class in this series.
0.13 in solar glass with anti-reflective surface treatment in accordance with EN12150
Printed as "Glass 0.13 in solar glass with anti-reflective surface treatment in accordance with EN12150" in REC Group's REC470AA PURE-RX-DC datasheet (REC Alpha Pure-RX domestic-content datasheet (UL)), captured on September 28, 2026.
Printed as "Torque 12 - 25 N-m / 106 - 221 lb-in" in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Securing of panels, Fig. 1-1 (clamp specifications). The clamp torque, printed as a range in two units; the first printed unit (N-m) is the value. The same 12 - 25 N-m is required for mounting-hole fixings (PDF page 10).
Where: PDF page 9, Securing of panels, Fig. 1-1 (clamp specifications)
Printed as "Rear (4-Point)* -4000 Pa (84 lbs/ft²)" in REC Alpha Pure-RX domestic-content datasheet (UL), Page 2, Maximum test load, Rear (4-Point). Revised on 1 October 2026: The datasheet prints the rear 4-point maximum test load as -4000 Pa, recorded as a magnitude.
W 1,205 × H 1,728 × D 30 mm / W 47.44 × H 68.03 × D 1.2 in converted
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "Dimensions 68.0 x 47.4 x 1.2 in (22.4 ft²) / 1728 x 1205 x 30 mm (2.08 m²) Weight 50.0 lb / 22.7 kg". General data table, one size for every watt class. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), row beginning "Dimensions 68.0 x 47.4"
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Power Output - PMAX (WP) 450 460 470". Nameplate power at STC, watt class sorting 0/+10 W. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to REC Group (cdn.myced.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "470", row beginning "Power Output - PMAX"
Printed as "Max Series Fuse Rating 25 A" in REC Alpha Pure-RX domestic-content datasheet (UL), Datasheet, maximum ratings table, "Max Series Fuse Rating" row. Revised on 1 October 2026: The REC datasheet prints "Max Series Fuse Rating 25 A" for every watt class in this series.
Where: Datasheet, maximum ratings table, "Max Series Fuse Rating" row
The panel must be secured, e.g., clamped, at least once in each of the four marked zones shown below (fig. 1-2).; Such installations have been found to be in compliance with IEC 61215 & IEC 61730 requirements for the maximum test loads of +7000 Pa downwards pressure and -4000 Pa upwards pressure (+4,667 Pa/-2,667 Pa design loads); 16.1 - 20.5 in 410 - 520 mm +1800 Pa / -1800 Pa* +1200 Pa / -1200 Pa +6200 Pa / -3000 Pa +3000 Pa / -2000 Pa +7000 Pa / -4000 Pa +4666 Pa / -2666 Pa; The REC solar panels covered by this manual can be installed utilizing the mounting holes (11 mm x 6.6 mm (0.43 in x 0.26in)) on the underside of the panel (fig. 1-4).
Printed as "The panel must be secured, e.g., clamped, at least once in each of the four marked zones shown below (fig. 1-2)." in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Installation of REC Alpha Pure-RX Series panels, continuous rails parallel to the short side (Fig. 3-3), with PDF page 9 (Securing of panels) and PDF page 10 (Mounting holes). The third line is the long side clamping zone row of the REC Alpha Pure-RX table with the highest loads, as printed: test load then design load for clearance gaps of 0.8 - 1.6 in, 1.6 - 2.4 in and >2.4 in; loads marked * were evaluated by REC's internal testing, not certified. Other zones, rails parallel to the long side, short rails and six-point mounting for the REC Alpha Pure-RX (PDF pages 29 to 32) print other loads. The first, second and fourth lines are from PDF pages 9 and 10.
Where: PDF page 28, Installation of REC Alpha Pure-RX Series panels, continuous rails parallel to the short side (Fig. 3-3), with PDF page 9 (Securing of panels) and PDF page 10 (Mounting holes)
The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 1-7),
Printed as "The cables must have a minimum bending radius of 1.2 in (30 mm) to avoid damage to the insulation (fig. 1-7)," in REC's Alpha Pure panels installation manual (UL edition, Rev 18, 3.2026), Cable management.
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "System Voltage 1000 V Max Series Fuse Rating 25 A". Module ratings table, one value for every watt class. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), row beginning "System Voltage 1000 V"
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Panel Efficiency (%) 21.6 22.1 22.6". Panel efficiency at STC. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), column "470", row beginning "Panel Efficiency (%) 21.6"
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "TEMPERATURE COEFFICIENT* PMAX -0.24%/°C". Temperature coefficient of PMAX, one value for every watt class; REC notes the coefficients are linear values. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), row beginning "TEMPERATURE COEFFICIENT* PMAX -0.24%/°C"
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC, column "470"; printed "Panel Efficiency (%) 21.6 22.1 22.6". Panel efficiency at STC. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Power temperature coefficient-0.24 %/°C14.7 / 16.0
0.24 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Read from the REC Alpha Pure-RX domestic-content US datasheet (UL EN 6.2026 V7), product code RECXXXAA PURE-RX-DC; printed "TEMPERATURE COEFFICIENT* PMAX -0.24%/°C". Temperature coefficient of PMAX, one value for every watt class; REC notes the coefficients are linear values. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 61730authority listing reportedlisted as of snapshot[6]
Scope
equipment listing
Covered models
REC470AA PURE-RX-DC
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC470AA Pure-RX-DC": UL 61730, certifying entity not printed on the list, CEC listing date 2026-03-11. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[6]
Scope
equipment listing
Covered models
REC470AA PURE-RX-DC
Limitations
Model REC470AA PURE-RX-DC listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC470AA Pure-RX-DC", CEC listing date 2026-03-11. The list prints "REC470AA Pure-RX-DC"; the record's model "REC470AA PURE-RX-DC" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
REC Group's own installation manual, captured September 28, 2026 with scripts/research/fetch.mjs from recgroup.com. UL 61730 edition, REF: PM-IM-23-06 REV: 18 UL EN 3.2026. Its cover states it is for all Alpha Pure solar panels certified to IEC 61215 & UL 61730 and names REC Alpha Pure 2, REC Alpha Pure-R and REC Alpha Pure-RX. It is a series-level manual: it establishes installation, handling, mounting and safety instructions for those series, not model-specific ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL 61730Manufacturer claim · equipment listingClaimedStatus unconfirmed
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Location: Page 2, Electrical Data / General Data / Module Ratings
Retrieved Sep 19, 2026
Covers product code RECXXXAA PURE-RX-DC in the 450-470 W classes only; identical electrical table to the standard Pure-RX sheet but a separate domestic-content assembly.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Manufacturer document mirrored by distributor; exact model and power column checked.
Archived copies
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by REC Group. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
REC470AA PURE-RX-DC
Manufacturer SKU REC470AA PURE-RX-DC
Observed Oct 11, 2026
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as REC Group "REC470AA Pure-RX-DC": UL 61730, certifying entity not printed on the list, CEC listing date 2026-03-11. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model REC470AA PURE-RX-DC listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under REC Group, as "REC470AA Pure-RX-DC", CEC listing date 2026-03-11. The list prints "REC470AA Pure-RX-DC"; the record's model "REC470AA PURE-RX-DC" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
Product / system scope unresolved. Manufacturer document claim for the named equipment. Issuer listing, exact revision and current status have not been independently checked. This is not a complete installed-system approval.
at Amazon, read Nov 16, 2026Price as of Nov 16, 2026, 5:25 AM PST, may change
at ACOPOWER, read Nov 15, 2026
View product →
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.