conditions: Qcells' Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) prints the series name Q.PEAK BLK-G4.1 and the power class 300, and no separate part number.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Frame
Black anodized aluminum
Printed in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "[A] 9.07 9.17 9.26 9.35". In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Where: Page 2, Electrical Characteristics, Minimum performance at STC, Current at MPP (IMPP) row, 300 W column
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "[A] 9.63 9.70 9.77 9.84". In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Where: Page 2, Electrical Characteristics, Minimum performance at STC, Short Circuit Current (ISC) row, 300 W column
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "[V] 31.96 32.19 32.41 32.62". In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Where: Page 2, Electrical Characteristics, Minimum performance at STC, Voltage at MPP (VMPP) row, 300 W column
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "[V] 39.19 39.48 39.76 40.05". In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Where: Page 2, Electrical Characteristics, Minimum performance at STC, Open Circuit Voltage (VOC) row, 300 W column
Printed as "Cell 6 × 10 monocrystalline Q.ANTUM solar cells" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Printed as "Weight 40.8 lbs (18.5 kg)" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Printed as a 6 × 10 cell layout ("Cell 6 × 10 monocrystalline Q.ANTUM solar cells") in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; 6 × 10 is 60 cells.
Printed as "Connector Stäubli MC4, Hanwha Q CELLS HQC4, Tonglin TL-Cable01S, Amphenol UTX; IP68" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Printed as "(85-115 mm × 60-80 mm × 15-20 mm), IP67, with bypass diodes" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; recorded from the protection rating onward.
A framed glass module: the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026 prints "Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology" and "Frame Black anodized aluminum".
Where: Page 2, Mechanical Specification, Front Cover and Frame
Design (not test) load, pull; printed as "[lbs / ft2] 75 (3600 Pa) / 55 (2667 Pa)" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The maximum test load is printed as "113 (5400 Pa) / 84 (4000 Pa)". The datasheet refers to the installation manual for these loads.
Where: Page 2, Properties for System Design, Max. Design Load, Push / Pull
W 1,000 × L 1,670 × D 32 mm / W 39.37 × L 65.75 × D 1.3 in converted
Printed in millimeters beside the inch figures as "Format 65.7 in × 39.4 in × 1.26 in (including frame) (1670 mm × 1000 mm × 32 mm)" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026, in the order printed.
Design (not test) load, push; printed as "[lbs / ft2] 75 (3600 Pa) / 55 (2667 Pa)" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The maximum test load is printed as "113 (5400 Pa) / 84 (4000 Pa)". The datasheet refers to the installation manual for these loads.
Where: Page 2, Properties for System Design, Max. Design Load, Push / Pull
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "290 295 300 305 [W] 290 295 300 305". The power tolerance is printed as +5 W / −0 W. In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Where: Page 2, Electrical Characteristics, Minimum performance at STC, Power at MPP (PMPP) row, 300 W column
Printed as "[A DC] 20" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Where: Page 2, Properties for System Design, Maximum Series Fuse Rating
Printed as "1000 (IEC) / 1000 (UL)" volts in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Where: Page 2, Properties for System Design, Maximum System Voltage VSYS
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "[%] ≥ 17.4 ≥ 17.7 ≥ 18.0 ≥ 18.3". Printed as a minimum, "≥ 18.0". In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Where: Page 2, Electrical Characteristics, Minimum performance at STC, Efficiency (η) row, 300 W column
Printed as "−40 °F up to +185 °F (−40 °C up to +85 °C)" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Where: Page 2, Properties for System Design, Permitted Module Temperature on Continuous Duty
Printed as "γ [% / K] −0.38" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; one value for the series. A change of one kelvin equals a change of one degree Celsius, so the figure is shown per °C.
Where: Page 2, Temperature Coefficients, Temperature Coefficient of PMPP (γ)
Printed as "α [% / K] +0.04" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; one value for the series. A change of one kelvin equals a change of one degree Celsius, so the figure is shown per °C.
Where: Page 2, Temperature Coefficients, Temperature Coefficient of ISC (α)
Printed as "β [% / K] −0.27" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; one value for the series. A change of one kelvin equals a change of one degree Celsius, so the figure is shown per °C.
Where: Page 2, Temperature Coefficients, Temperature Coefficient of VOC (β)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the 300 W column (3 of 4) of the Q.PEAK BLK-G4.1 power class table (power classes 290, 295, 300, 305), block "MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC" (STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3), in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. The row's values print "[%] ≥ 17.4 ≥ 17.7 ≥ 18.0 ≥ 18.3". Printed as a minimum, "≥ 18.0". In the PDF text layer the value rows follow the power class row and precede their labels; on the page they sit beside the labels in one table.
Printed as "Inclusive 12-year product warranty and 25-year linear performance warranty2" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; footnote 2 refers to the rear of the datasheet. Headline figure only; the datasheet states full warranties follow the warranty terms of the Q CELLS sales organization of the buyer's country.
Printed as "Inclusive 12-year product warranty and 25-year linear performance warranty2" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
0.38 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "γ [% / K] −0.38" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; one value for the series. A change of one kelvin equals a change of one degree Celsius, so the figure is shown per °C.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 61215:2016manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Q.PEAK BLK-G4.1 300
Limitations
Qcells' own Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) lists "IEC 61215:2016" under QUALIFICATIONS AND CERTIFICATES for the series that includes Q.PEAK BLK-G4.1 300 (power classes 290, 295, 300, 305). Read from an Internet Archive copy captured on December 5, 2024 and retrieved on September 25, 2026; the datasheet describes the product as documented then. Recorded as the manufacturer prints it; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
IEC 61730:2016manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Q.PEAK BLK-G4.1 300
Limitations
Qcells' own Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) lists "IEC 61730:2016, Application Class II" under QUALIFICATIONS AND CERTIFICATES for the series that includes Q.PEAK BLK-G4.1 300 (power classes 290, 295, 300, 305). Read from an Internet Archive copy captured on December 5, 2024 and retrieved on September 25, 2026; the datasheet describes the product as documented then. Recorded as the manufacturer prints it; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
Q.PEAK BLK-G4.1 300
Limitations
Qcells' own Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) lists "UL 1703" under QUALIFICATIONS AND CERTIFICATES and carries a certification mark printed "Certified UL 1703 (254141)"; the number in brackets is printed without a label for the series that includes Q.PEAK BLK-G4.1 300 (power classes 290, 295, 300, 305). Read from an Internet Archive copy captured on December 5, 2024 and retrieved on September 25, 2026; the datasheet describes the product as documented then. Recorded as the manufacturer prints it; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 1703authority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
Q.PEAK BLK-G4.1 300
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Qcells North America "Q.PEAK BLK-G4.1 300": UL 1703, certifying entity not printed on the list, CEC listing date 2017-08-01. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
Q.PEAK BLK-G4.1 300
Limitations
Model Q.PEAK BLK-G4.1 300 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Qcells North America, as "Q.PEAK BLK-G4.1 300", CEC listing date 2017-08-01. This is an equipment listing, not UL certification or complete-system approval.
Warranted output at year 25, printed as "At least 83.6 % of nominal power up to 25 years." in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026. All data within measurement tolerances, as the datasheet states.
Printed as "Inclusive 12-year product warranty and 25-year linear performance warranty2" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026; footnote 2 refers to the rear of the datasheet. Headline figure only; the datasheet states full warranties follow the warranty terms of the Q CELLS sales organization of the buyer's country.
Maximum yearly degradation after the first year, printed as "Thereafter max. 0.6 % degradation per year." after "At least 98 % of nominal power during first year." in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
Printed as "Inclusive 12-year product warranty and 25-year linear performance warranty2" in the Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA), Internet Archive copy of December 5, 2024, read on September 25, 2026.
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
Qcells' own Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) lists "UL 1703" under QUALIFICATIONS AND CERTIFICATES and carries a certification mark printed "Certified UL 1703 (254141)"; the number in brackets is printed without a label for the series that includes Q.PEAK BLK-G4.1 300 (power classes 290, 295, 300, 305). Read from an Internet Archive copy captured on December 5, 2024 and retrieved on September 25, 2026; the datasheet describes the product as documented then. Recorded as the manufacturer prints it; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
IEC 61215:2016Manufacturer claim · equipment listingClaimedListed when checked
Qcells' own Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) lists "IEC 61215:2016" under QUALIFICATIONS AND CERTIFICATES for the series that includes Q.PEAK BLK-G4.1 300 (power classes 290, 295, 300, 305). Read from an Internet Archive copy captured on December 5, 2024 and retrieved on September 25, 2026; the datasheet describes the product as documented then. Recorded as the manufacturer prints it; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
IEC 61730:2016Manufacturer claim · equipment listingClaimedListed when checked
Qcells' own Q.PEAK BLK-G4.1 290-305 datasheet (Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA) lists "IEC 61730:2016, Application Class II" under QUALIFICATIONS AND CERTIFICATES for the series that includes Q.PEAK BLK-G4.1 300 (power classes 290, 295, 300, 305). Read from an Internet Archive copy captured on December 5, 2024 and retrieved on September 25, 2026; the datasheet describes the product as documented then. Recorded as the manufacturer prints it; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Page 2 Mechanical Specification, Electrical Characteristics, Temperature Coefficients, Properties for System Design, Qualifications and Certificates
Retrieved Sep 24, 2026
Internet Archive copy, captured on December 5, 2024, of Qcells' own North American datasheet PDF at https://us.qcells.com/wp-content/uploads/2023/07/Q_CELLS_Data_sheet_Q.PEAK_BLK-G4.1_290-305_2019-03_Rev02_NA.pdf; not a live manufacturer document. Retrieved from the Internet Archive on September 25, 2026 because Qcells' own sites refuse automated access. The PDF carries the Q CELLS name, the Hanwha Q CELLS America Inc. address and the revision code Q.PEAK BLK-G4.1_290-305_2019-03_Rev02_NA. Electrical figures are Qcells' minimum performance at standard test conditions for each power class column.
Archived copies
Archived copy of a document published by Qcells. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Qcells. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Q.PEAK BLK-G4.1 300
Manufacturer SKU unknown · US market
Observed Oct 11, 2026
UL 1703: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Qcells North America "Q.PEAK BLK-G4.1 300": UL 1703, certifying entity not printed on the list, CEC listing date 2017-08-01. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model Q.PEAK BLK-G4.1 300 listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Qcells North America, as "Q.PEAK BLK-G4.1 300", CEC listing date 2017-08-01. This is an equipment listing, not UL certification or complete-system approval.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.