Key specs

Units
Rated output (STC)
500 W
Official document
Sources

Front-side STC: 1000 W/m², cell temperature 25°C, AM1.5. Selected source revision only.

Official document: Peimar reference document Checked · Earlier document

Location: Physical PDF page 2; Nominal Output (Pmax) (2)

Documented

Module efficiency
21.33 %
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "21,33%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Module Efficiency" row

Documented

Voltage at max power (Vmp)
37.77 V
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "37,77 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Voltage at Pmax (Vmp)" row

Documented

Current at max power (Imp)
13.24 A
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "13,24 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Current at Pmax (Imp)" row

Documented

Open-circuit voltage (Voc)
46.46 V
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "46,46 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Open Circuit Voltage (Voc) (2)" row

Documented

Short-circuit current (Isc)
14.03 A
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "14,03 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Short Circuit Current (Isc) (2)" row

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Peimar SA500M (BF) datasheet (EN_2026_07_00), printed value for this model.

Official datasheet: Peimar SA500M (BF) datasheet Rev EN_2026_07_00 · Checked · Earlier document

Location: Page 2, Temperature Characteristics, "Temperature Coefficient of Pmax"

Documented

Maximum system voltage
1,500 V
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "1500 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Maximum System Voltage" row

Documented

All specs25
Rated output (STC)
500 W
Official document
Sources

Front-side STC: 1000 W/m², cell temperature 25°C, AM1.5. Selected source revision only.

Official document: Peimar reference document Checked · Earlier document

Location: Physical PDF page 2; Nominal Output (Pmax) (2)

Documented

Module efficiency
21.33 %
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "21,33%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Module Efficiency" row

Documented

Voltage at max power (Vmp)
37.77 V
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "37,77 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Voltage at Pmax (Vmp)" row

Documented

Current at max power (Imp)
13.24 A
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "13,24 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Current at Pmax (Imp)" row

Documented

Open-circuit voltage (Voc)
46.46 V
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "46,46 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Open Circuit Voltage (Voc) (2)" row

Documented

Short-circuit current (Isc)
14.03 A
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "14,03 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Short Circuit Current (Isc) (2)" row

Documented

Power temperature coefficient
-0.29 %/°C
Official datasheet
Sources

Peimar SA500M (BF) datasheet (EN_2026_07_00), printed value for this model.

Official datasheet: Peimar SA500M (BF) datasheet Rev EN_2026_07_00 · Checked · Earlier document

Location: Page 2, Temperature Characteristics, "Temperature Coefficient of Pmax"

Documented

Maximum system voltage
1,500 V
Official document
Sources

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "1500 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document

Location: PDF page 2, "Maximum System Voltage" row

Documented

Published claims and calculations, not independent test results.

Documents

3 on file
  • PDF
    Peimar SA500M (BF) datasheetOfficialPeimarOfficial datasheet
    Source details
    Revision
    EN_2026_07_00
    Revision date
    Not stated

    Location: Page 2, Electrical Characteristics (STC) / Mechanical Characteristics / Temperature Characteristics

    Retrieved

    Single-model Peimar datasheet for SA500M (BF); STC values carry a +/-3% measurement tolerance and the sheet covers no other Peimar model or finish variant.

    Archived copies

    Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.46 MB

    Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 1bfbfbe3f2cc6d2e3df8e158fc93d8538f8db4bee999bdb76fcacf0682d53695

    Open
  • PDF
    Peimar EN Installation Manual Photovoltaic Modules (general installation manual, linked from the maker's product page; English edition, Version EN_2024_12_00)OfficialPeimarOfficial installation manual
    Source details
    Revision
    EN_2024_12_00
    Revision date
    Not stated

    Archived copy captured on 2026-10-01.

    Location: Cover page and sections 2 (Introduction) and 3 (Applications)

    Retrieved

    Peimar's own general installation manual for its photovoltaic modules, captured 1 October 2026 from peimar.com. It names no model or series; it is attached to a record only because Peimar's own modules page, which lists that model with its data sheets, links this file as the modules installation manual. Version EN_2024_12_00 as printed on the back cover. Its scope is Peimar photovoltaic modules in general: modules made of crystalline-silicon cells with a plastic back sheet (monofacial) or tempered glass back (bifacial) and an anodized aluminum frame. Only its general installation instructions (mounting methods and grounding stated for all modules) are used; it establishes no model rating, load rating or clamp zone for a particular model. Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup EN_2024_12_00 · 1.00 MB

    Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/documents/Peimar_EN_Installation-Manual.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    20
    Embedded creation date
    Dec 2, 2024
    Embedded modification date
    Dec 2, 2024

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d688c76758d03e58a3338c3c59745c324c5677fafb849dc64b1590f9eb8f537d

    Open
  • WEB
    Peimar en-US photovoltaic modules indexOfficialPeimarOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Modules index, datasheet download list

    Retrieved

    Index page listing every Peimar module datasheet by language; it links the per-model PDFs but publishes no electrical values itself.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Peimar reference document

Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.46 MB

Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Jul 9, 2026
Embedded modification date
Jul 9, 2026

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 1bfbfbe3f2cc6d2e3df8e158fc93d8538f8db4bee999bdb76fcacf0682d53695

Peimar EN Installation Manual Photovoltaic Modules (general installation manual, linked from the maker's product page; English edition, Version EN_2024_12_00)

Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup EN_2024_12_00 · 1.00 MB

Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/documents/Peimar_EN_Installation-Manual.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
20
Embedded creation date
Dec 2, 2024
Embedded modification date
Dec 2, 2024

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d688c76758d03e58a3338c3c59745c324c5677fafb849dc64b1590f9eb8f537d

Submit a document

Warranty

Product warranty
30 years
Official datasheet
Sources

Official datasheet: Peimar SA500M (BF) datasheet Rev EN_2026_07_00 · Checked · Earlier document

Location: Page 1, warranty badge, "Product warranty"

Documented

Power warranty
30 years
Official datasheet
Sources

Official datasheet: Peimar SA500M (BF) datasheet Rev EN_2026_07_00 · Checked · Earlier document

Location: Page 1, warranty badge, "Linear power warranty"

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

72/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency21.33 %21.7 / 26.0

21.33 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, from the only model this document publishes, SA500M (BF). Printed value: "21,33%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official document: Peimar reference document Checked · Earlier document
Product warranty30 years21.0 / 21.0

This is the best documented for a solar panel, printed by the maker. 87 solar panels share this value.

Official datasheet: Peimar SA500M (BF) datasheet Rev EN_2026_07_00 · Checked · Earlier document
Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the maker. 869 solar panels share this value.

Official datasheet: Peimar SA500M (BF) datasheet Rev EN_2026_07_00 · Checked · Earlier document

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

2 on file2 claims on file · issuer check pending
IEC 61215Product / system scope unresolvedClaimedStatus unconfirmed

Peimar prints "IEC 61215" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, a document this catalog already attaches to SA500M (BF); the value was located through a page that names SA500M (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Models: SA500M (BF)

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official document: Peimar reference document Checked · Earlier document
IEC 61730Product / system scope unresolvedClaimedStatus unconfirmed

Peimar prints "IEC 61730" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, a document this catalog already attaches to SA500M (BF); the value was located through a page that names SA500M (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Models: SA500M (BF)

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official document: Peimar reference document Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SA500M (BF)

IEC 61215: claimed

Product / system scope unresolved. Peimar prints "IEC 61215" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, a document this catalog already attaches to SA500M (BF); the value was located through a page that names SA500M (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Official document: Peimar reference document Checked · Earlier document

IEC 61730: claimed

Product / system scope unresolved. Peimar prints "IEC 61730" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_SA500M(BF).pdf, a document this catalog already attaches to SA500M (BF); the value was located through a page that names SA500M (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Official document: Peimar reference document Checked · Earlier document

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?