Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "13,54 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "14,26 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Short Circuit Current (Isc) (2)" row
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "36,93 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "43,32 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Open Circuit Voltage (Voc) (2)" row
On a grounding hole with a diameter of φ4 mm, use a separate grounding wire and related accessories to connect the aluminum frame of the solar PV module and connect the grounding wire to the ground.; The grounding uses the M4*12mm bolts and M4 nuts, star washers and plain washers, this ensures that the modules are firmly grounded.; The torque applied to ground fixation is 4N·m~8N·m.; It is recommended to use the copper wire (4-14mm2 or AWG 6-12) as the grounding wire.
Printed as "On a grounding hole with a diameter of φ4 mm, use a separate grounding wire and related accessories to connect the aluminum frame of the solar PV module and connect the grounding wire to the ground." in section 5.6.4 Grounding (PDF page 31) of Peimar's PV Modules Installation Manual, Double Glass & Bifacial Double Glass Modules (no revision printed). The same section prints M4*12mm bolts with M4 nuts, star washers and plain washers, a ground fixation torque of 4N·m to 8N·m and copper grounding wire of 4-14mm2 (AWG 6-12); PDF page 32 adds grounding by unused mounting holes or other certified grounding devices. Series-level instruction.
Where: PDF page 31 and 32, section 5.6.4 Grounding
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "25,7 kg / 56,66 lbs". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Printed as "Front Cover 2,0 mm / 0,08” thick, low iron tempered glass" in Peimar's OR 10H500MNDB (BF) datasheet (Peimar OR 10H500MNDB (BF) datasheet), captured on September 28, 2026.
Where: Datasheet page 2, Mechanical Characteristics, Front Cover row
Printed as "tighten to a torque of 16~20 N.m" for the M8 bolt securing the module at each mounting location, on PDF page 18 of Peimar's PV Modules Installation Manual, Double Glass & Bifacial Double Glass Modules (no revision printed); the tightening steps repeat "Use torque wrench to tighten nut to target torque: 16~20N.m". For clamps, PDF page 22 prints "ex: M8 16- 20N.m" as an example. Printed unit N.m, stored as N·m. Series-level instruction.
Where: PDF page 18, section 5.5.1 Mechanical installation and warning
Printed as "Back Cover 2,0 mm / 0,08” thick, low iron tempered glass" in Peimar's OR 10H500MNDB (BF) datasheet (Peimar OR 10H500MNDB (BF) datasheet), captured on September 28, 2026.
Where: Datasheet page 2, Mechanical Characteristics, Back Cover row
Printed as "Max Load (Test Load) - SF 5400 Pa - 1,5 (5)" in Peimar OR 10H500MNDB (BF) datasheet, Page 2, Mechanical Characteristics, "Max Load (Test Load) - SF" row. Revised on 1 October 2026: The data sheet prints this figure as the maximum test load with a safety factor of 1,5, so it must be shown with that printed label rather than as a plain load rating.
A. Mounting with Bolts 4-φ9*14mm mounting holes, (Applicable to framed Double-glass and framed Bifacial double-glass); Length≤2400mm Uplift load ≤2400Pa Downforce load ≤5400Pa; Length≤2000mm Uplift load ≤2400Pa Downforce load ≤3600Pa; Mounting with Clamps applied for framed Double-glass and Bifacial double-glass; The clamp must overlap the module frame by at least 7mm but no more than 10mm.; Use at least 4 clamps to attach modules to the mounting rails.; Length≤2400mm Uplift load ≤2400Pa Downforce load ≤5400Pa; Length≤2000mm Uplift load ≤2400Pa Downforce load ≤3600Pa
Printed as "A. Mounting with Bolts 4-φ9*14mm mounting holes, (Applicable to framed Double-glass and framed Bifacial double-glass)" on PDF page 18 and as "Mounting with Clamps applied for framed Double-glass and Bifacial double-glass" on PDF page 22 of Peimar's PV Modules Installation Manual, Double Glass & Bifacial Double Glass Modules (no revision printed). For both bolts (PDF page 19 and 20) and clamps (PDF page 22 and 23) the manual prints the same load rows: "Length≤2400mm Uplift load ≤2400Pa Downforce load ≤5400Pa" with the crossbeam perpendicular to the long side, which it says it does not recommend for framed bifacial double-glass because it may cover the cells, and rows by module length with the beam parallel to the long side. The row listed is the one for this model's recorded length of 1903 mm (Length≤2000mm). The manual states: "The mechanical loads described in this manual are the test loads." It applies a safety factor of 1.5 to reach design loads and does not print design loads. Clamp centerlines go at 1/6L≤A≤1/4L from the module edge. Single-axis tracker mounting and frameless clamp mounting (PDF page 20 to 26) are not listed because this model has a frame and those rows are for other configurations. Series-level instructions for Peimar's double glass modules, not a test of this model.
Where: PDF page 18 to 23, section 5.5.1 Mechanical installation and warning (A. Mounting with Bolts; Mounting with Clamps)
The minimum bending radius of the cables must be 43mm.
Printed as "The minimum bending radius of the cables must be 43mm." in section 5.6.2 Electrical Connection (PDF page 29) of Peimar's PV Modules Installation Manual, Double Glass & Bifacial Double Glass Modules (no revision printed). Series-level instruction.
Where: PDF page 29, section 5.6.2 Electrical Connection
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "1500 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "23,17%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, from the only model this document publishes, OR10H500MNDB (BF). Printed value: "23,17%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Peimar prints "IEC 61215" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, a document this catalog already attaches to OR10H500MNDB (BF); the value was located through a page that names OR10H500MNDB (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Peimar prints "IEC 61730" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, a document this catalog already attaches to OR10H500MNDB (BF); the value was located through a page that names OR10H500MNDB (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Location: Cover page, module types table on PDF page 2 and section 1 (Introduction)
Retrieved Oct 1, 2026
Peimar's own installation manual for its double glass and bifacial double glass modules, captured 1 October 2026 from peimar.com, where it sits in an Australian data sheet folder; Peimar's modules pages do not link it and it prints no revision or date. Its module types table names the OR12H and OR10H MNDB double glass models (for example OR12H715MNDB, OR10H595MNDB, OR10H500MNDB and OR10H450MNDB). It gives series-level handling, mounting (with test loads, not design loads), grounding and wiring instructions; its rating tables are headed as examples provided for reference. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Single-model Peimar datasheet for OR 10H500MNDB (BF); STC values carry a +/-3% measurement tolerance and the sheet covers no other Peimar model or finish variant.
Archived copies
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Peimar reference document
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
OR10H500MNDB (BF)
Observed Sep 19, 2026
IEC 61215: claimed
Product / system scope unresolved. Peimar prints "IEC 61215" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, a document this catalog already attaches to OR10H500MNDB (BF); the value was located through a page that names OR10H500MNDB (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Product / system scope unresolved. Peimar prints "IEC 61730" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H500MNDB%28BF%29.pdf, a document this catalog already attaches to OR10H500MNDB (BF); the value was located through a page that names OR10H500MNDB (BF) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.