Peimar OR10H440MNDB (FB)

Key specs

Rated power440 W
Weight23.24 kg / 51.24 lb converted
Open-circuit voltage38.71 V
Short-circuit current14.13 A
Voltage at max power33.01 V
Current at max power13.33 A

1 spec not documented yet: dimensionsHelp fill in ›

All specifications

Identity

BrandPeimar · Website
ModelOR10H440MNDB (FB)
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
FrameAnodized aluminium alloy, double wall, black finish
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Mechanical Characteristics, "Frame" / "Frame finishing"
[1]
Current at max power13.33 A
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "13,33 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Current at Pmax (Imp)" row
[2]
Short-circuit current14.13 A
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "14,13 A". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Short Circuit Current (Isc) (2)" row
[2]
Voltage at max power33.01 V
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "33,01 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Voltage at Pmax (Vmp)" row
[2]
Open-circuit voltage38.71 V
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "38,71 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Open Circuit Voltage (Voc) (2)" row
[2]
Bifacialyes
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 1, key features, "TOPCon bifacial technology"
[1]
Cell typeM10 HALF monocrystalline N-TYPE
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Mechanical Characteristics, "Solar Cells"
[1]
GroundingAll module frames should be grounded for safety.; Attach a separate ground wire to grounding holes on modules frame with a self tapping screw.; Assemble the recommended grounding lug to the Aluminum frame using stainless steel M3, M4 or M5 screw and hardware as shown below.; Recommended torque of M3, M4 or M5 screw assembly is 0.8NM or 1.5NM.; ground wires greater than 10AWG is recommended
Printed as "All module frames should be grounded for safety." in section 6.3 Grounding (PDF page 13) of Peimar's EN Installation Manual Photovoltaic Modules (Version EN_2024_12_00), Peimar's general installation manual (linked from the maker's product page), which continues on PDF page 14 with the grounding lug assembly (stainless steel M3, M4 or M5 screw, star washer under the lug, flat washer, split lock washer and nut) and its recommended torque, printed as 0.8NM or 1.5NM. The manual notes two grounding hole sizes, the smaller being phased out, and labels the M5 drawing for modules with 5.1 mm grounding holes. General instructions for Peimar's photovoltaic modules, not specific to this model.
Where: PDF page 13 and 14, section 6.3 Grounding
[3]
Weight23.24 kg / 51.24 lb converted
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "23,24 kg / 51,2 lbs - 23,77 kg / 52,4 lbs". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Weight" row
[2]
Cell count108 cells
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Mechanical Characteristics, "Solar Cells"
[1]
ConnectorsMC4 or compatible connector
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Mechanical Characteristics, "Connector"
[1]
Front glass2,0 mm / 0,08” thick, low iron tempered glass
Printed as "Front Cover 2,0 mm / 0,08” thick, low iron tempered glass" in Peimar's OR 10H440MNDB (FB) datasheet (Peimar OR 10H440MNDB (FB) datasheet), captured on September 28, 2026.
Where: Datasheet page 2, Mechanical Characteristics, Front Cover row
[1]
Junction boxIP68 rated, 3 bypass diodes
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Mechanical Characteristics, "Junction Box" / "Diodes"
[1]
Rear surface2,0 mm / 0,08” thick, low iron tempered glass
Printed as "Back Cover 2,0 mm / 0,08” thick, low iron tempered glass" in Peimar's OR 10H440MNDB (FB) datasheet (Peimar OR 10H440MNDB (FB) datasheet), captured on September 28, 2026.
Where: Datasheet page 2, Mechanical Characteristics, Back Cover row
[1]
Front load pa5,400 Pa
Printed as "Max Load (Test Load) - SF 5400 Pa - 1,5 (5)" in Peimar OR 10H440MNDB (FB) datasheet, Page 2, Mechanical Characteristics, "Max Load (Test Load) - SF" row. Revised on 1 October 2026: The data sheet prints this figure as the maximum test load with a safety factor of 1,5, so it must be shown with that printed label rather than as a plain load rating.
Where: Page 2, Mechanical Characteristics, "Max Load (Test Load) - SF" row
[1]
Rated power440 W
Front-side STC: 1000 W/m², cell temperature 25°C, AM1.5. Selected source revision only.
Where: Physical PDF page 2; Nominal Output (Pmax) (2)
[2]
Series fuse30 A
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Electrical Characteristics, "Maximum Series Fuse Rating"
[1]
Mounting methodsMounting using bolt holes; Modules should be bolted to support structures through mounting holes located in the frame’s back flanges only.; Mounting using “clamping method” and profile insert; Each module must be securely fastened at a minimum of 4 points on two opposite sides.
Printed as "Mounting using bolt holes" (section 5.5.1, PDF page 8) and as "Mounting using “clamping method” and profile insert" (section 5.5.2, PDF page 9) in Peimar's EN Installation Manual Photovoltaic Modules (Version EN_2024_12_00), Peimar's general installation manual (linked from the maker's product page). Bolt mounting uses the mounting holes in the frame's back flanges only; clamp mounting needs at least 4 points on two opposite sides. The manual names no model; its clamp zone tables (by cell count and cell size) and approved load figures are not repeated here because they are not stated for this model. General instructions for Peimar's photovoltaic modules, not a test of this model.
Where: PDF page 8 and 9, section 5.5 Mounting (5.5.1 bolt holes, 5.5.2 clamping method and profile insert)
[3]
Max system voltage1,500 V
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "1500 V". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Maximum System Voltage" row
[2]
Module efficiency22.02 %
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "22,02% | 22,53%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 2, "Module Efficiency" row
[2]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Temperature Characteristics, "Operating Temperature"
[1]
Temperature coefficient-0.29 %/°C
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Temperature Characteristics, "Temperature Coefficient of Pmax"
[1]
Isc temperature coefficient0.046 %/°C
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Temperature Characteristics, "Temperature Coefficient of Isc"
[1]
Voc temperature coefficient-0.25 %/°C
Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.
Where: Page 2, Temperature Characteristics, "Temperature Coefficient of Voc"
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
440 WEfficiency 22.02 %
Voltage (STC)
33.01 VVmp · maximum powerVoc · open circuit 38.71 VMax system 1,500 V
Current (STC)
13.33 AImp · maximum powerIsc · short circuit 14.13 A
Dimensions
Not statedWeight 23.24 kg / 51.24 lb
Warranty
25 yearsPower warranty 30 years

Evidence score

69/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency22.02 %22.5 / 26.0

22.02 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from Peimar's published document at https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, from the only model this document publishes, OR10H440MNDB (FB). Printed value: "22,02% | 22,53%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

[2]

Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the maker. 870 solar panels share this value.

[1]

Power temperature coefficient-0.29 %/°C12.1 / 16.0

0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Peimar OR 10H440MNDB (FB) datasheet (EN_2026_06_00), printed value for this model.

[1]

Weight / watt23.24 kg / 440 W1.2 / 5.0

0.05282 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module

23.24 kg / 440 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.

[2]

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 61215manufacturer claimunknown[2]
Scope
equipment listing
Covered models
OR10H440MNDB (FB)
Limitations
Peimar prints "IEC 61215" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, a document this catalog already attaches to OR10H440MNDB (FB); the value was located through a page that names OR10H440MNDB (FB) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 19, 2026
Source
[2]
IEC 61730manufacturer claimunknown[2]
Scope
equipment listing
Covered models
OR10H440MNDB (FB)
Limitations
Peimar prints "IEC 61730" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, a document this catalog already attaches to OR10H440MNDB (FB); the value was located through a page that names OR10H440MNDB (FB) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 19, 2026
Source
[2]

Warranty

FieldValueConditionsSource
Warranty term25 years
Where: Page 1, warranty badge, "Product warranty"
[1]
Performance warranty30 years
Where: Page 1, warranty badge, "Linear power warranty"
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Peimar EN Installation Manual Photovoltaic Modules (general installation manual, linked from the maker's product page; English edition, Version EN_2024_12_00)Official · Peimar · Official installation manual · PDF
    Source details
    Revision
    EN_2024_12_00
    Revision date
    Not stated

    Archived copy captured on 2026-10-01.

    Location: Cover page and sections 2 (Introduction) and 3 (Applications)

    Retrieved Oct 1, 2026

    Peimar's own general installation manual for its photovoltaic modules, captured 1 October 2026 from peimar.com. It names no model or series; it is attached to a record only because Peimar's own modules page, which lists that model with its data sheets, links this file as the modules installation manual. Version EN_2024_12_00 as printed on the back cover. Its scope is Peimar photovoltaic modules in general: modules made of crystalline-silicon cells with a plastic back sheet (monofacial) or tempered glass back (bifacial) and an anodized aluminum frame. Only its general installation instructions (mounting methods and grounding stated for all modules) are used; it establishes no model rating, load rating or clamp zone for a particular model. Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupEN_2024_12_00 · 1.00 MB

    Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/documents/Peimar_EN_Installation-Manual.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    20

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d688c76758d03e58a3338c3c59745c324c5677fafb849dc64b1590f9eb8f537d

    Open
  • Datasheets

  • Peimar OR10H440MNDB (FB) datasheetOfficial · Peimar · Official datasheet · PDF
    Source details
    Revision
    EN_2026_06_00
    Revision date
    Not stated

    Location: Page 2, Electrical Characteristics (STC) / Mechanical Characteristics / Temperature Characteristics

    Retrieved Sep 19, 2026

    Single-model Peimar datasheet for OR 10H440MNDB (FB); STC values carry a +/-3% measurement tolerance and the sheet covers no other Peimar model or finish variant.

    Archived copies

    Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.15 MB

    Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 31415f2ac4a1b702548dfa1565388138b42aad48a3242a56ac7fd8a525138dd1

    Open
  • Other documents

  • Peimar en-US photovoltaic modules indexOfficial · Peimar · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Modules index, datasheet download list

    Retrieved Sep 19, 2026

    Index page listing every Peimar module datasheet by language; it links the per-model PDFs but publishes no electrical values itself.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Peimar reference document

Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.15 MB

Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 31415f2ac4a1b702548dfa1565388138b42aad48a3242a56ac7fd8a525138dd1

Peimar EN Installation Manual Photovoltaic Modules (general installation manual, linked from the maker's product page; English edition, Version EN_2024_12_00)

Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupEN_2024_12_00 · 1.00 MB

Archived copy, unaltered, kept as a record of what Peimar published. Original address: https://peimar.com/documents/Peimar_EN_Installation-Manual.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
20

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d688c76758d03e58a3338c3c59745c324c5677fafb849dc64b1590f9eb8f537d

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
OR10H440MNDB (FB)
  1. Observed Sep 19, 2026

    IEC 61215: claimed

    Product / system scope unresolved. Peimar prints "IEC 61215" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, a document this catalog already attaches to OR10H440MNDB (FB); the value was located through a page that names OR10H440MNDB (FB) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    [2]

  2. Observed Sep 19, 2026

    IEC 61730: claimed

    Product / system scope unresolved. Peimar prints "IEC 61730" in a certification, standards or compliance row on PDF page 2 of https://peimar.com/datasheet/Peimar_EN_OR10H440MNDB%28FB%29.pdf, a document this catalog already attaches to OR10H440MNDB (FB); the value was located through a page that names OR10H440MNDB (FB) and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    [2]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 84
basis: Unknown
missing:
First-year degradation needed
criteria:
key: efficiency
label: Module efficiency
value: 22.02
unit: Unknown
shown: 22.02 %
shown detail: Unknown
state: documented
points: 22.5
ceiling: 26
weight: 26
share: 86.4
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: warranty
label: Product warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 17.5
ceiling: 21
weight: 21
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: performanceWarranty
label: Power warranty
value: 30
unit: Unknown
shown: 30 years
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: powerTemperature
label: Power temperature coefficient
value: 0.29
unit: Unknown
shown: -0.29 %/°C
shown detail: Unknown
state: documented
points: 12.1
ceiling: 16
weight: 16
share: 75.9
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0528
unit: Unknown
shown: 23.24 kg / 440 W
shown detail: Unknown
state: documented
points: 1.2
ceiling: 5
weight: 5
share: 23.2
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 23.24 kg / 440 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
display note: Unknown
Sources: [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Peimar OR10H440MNDB (FB) datasheet (Peimar · manufacturer · EN 2026 06 00 · observed Sep 19, 2026)
  2. Peimar reference document (Peimar · manufacturer · observed Sep 15, 2026)
  3. Peimar EN Installation Manual Photovoltaic Modules (general installation manual, linked from the maker's product page; English edition, Version EN_2024_12_00) (Peimar · manufacturer · EN 2024 12 00 · observed Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price