conditions: Panasonic prints the model number VBHN315KA01 in its datasheet model rows and on its product pages, and no separate SKU or part number.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Current at max power
5.4 A
Printed as "Maximum Power Current (Ipm) 5.46 5.40 5.34" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Maximum Power Current (Ipm) row, VBHN315KA01 column
Printed as "Short Circuit Current (Isc) 5.89 5.83 5.78" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Short Circuit Current (Isc) row, VBHN315KA01 column
Printed as "Maximum Power Voltage (Vpm) 58.7 58.4 58.1" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Maximum Power Voltage (Vpm) row, VBHN315KA01 column
Printed as "Open Circuit Voltage (Voc) 70.5 70.2 69.9" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Open Circuit Voltage (Voc) row, VBHN315KA01 column
Printed as "Silicon hetero-junction*" in every column of the Cell Type row of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), with the footnote "Silicon hetero-junction*: Monocrysttaline silicon/amorphous silicon hetero-junction".
Where: PDF page 11, Specifications table, Cell Type row
Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).; Star washers must be used to make contact through the anodization of the module frame.; Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb).; Use Tyco Electronics 1954381-2 as grounding clip.
Printed as "Each ledge on the module frame has two larger holes for bolts (0.205’‘diameter (5.2 mm)).", "Star washers must be used to make contact through the anodization of the module frame.", "Recommended torque value in tightening bolt and nut is 2.3 N.m (20in-lb)." and "Use Tyco Electronics 1954381-2 as grounding clip." on PDF page 6 of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20); statements for all the models it covers.
Where: PDF page 6, Earth Ground Wiring, Grounding Locations and Grounding Methods
Panasonic's installation manual and Panasonic's data sheet differ for this field. Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20) prints 19 kg for VBHN315KA01; Panasonic's data sheet recorded earlier gives 18.5 kg. The manual's value is shown first; the earlier value is kept below.
Printed as "Mechanical Specifications Length, mm (inches) Width, mm (inches) Frame Depth, mm (inches) Weight, kg (pounds) Electrical Specifications 1590 (62.60) 1053 (41.46) 35 (1.38) 19 (41.89)" in Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20); the weight reads 19 kg (41.89 pounds), one value for all three models. Revised on 1 October 2026: The installation manual, first in the owner's source order, prints a different value for this model than Panasonic's data sheet recorded earlier; the recorded value is kept beside it.
Where: PDF page 11, Specifications table, Mechanical Specifications, Weight row
Sources
18.5 kg
Printed as "Weight 40.81 Lbs. (18.5kg)" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024) under "MECHANICAL SPECIFICATIONS Model VBHN320KA01, VBHN315KA01, VBHN310KA01", read on September 25, 2026.
Printed as "Cell Number in Series 96 96 96" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Cell Number in Series row, VBHN315KA01 column
Printed as "Connector Type2 Multi-Contact® Type IV (MC4™)" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024); the footnote says a safety locking clip (PV-SSH4) is not supplied with the module. Read on September 25, 2026.
Where: Page 2 Mechanical Specifications, Connector Type
Printed as "Recommendation of bolt torque: 10 ft-lbs." in Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20) (printed unit spelling "ft-lbs"), for mounting with a bolt and nut as Figure 1-2 shows; the tested Unirac clamps list "Torque: 13.6 N.m(10 ft-lbs)." and the IronRidge clamps "Torque: 9.5 N.m (85 in-lbs)." A statement for all the models it covers.
W 1,053 × L 1,590 × D 35 mm / W 41.46 × L 62.6 × D 1.4 in converted
Printed as "Mechanical Specifications Length, mm (inches) Width, mm (inches) Frame Depth, mm (inches) Weight, kg (pounds) Electrical Specifications 1590 (62.60) 1053 (41.46) 35 (1.38) 19 (41.89)" in Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20); the text layer lists the four mechanical row labels before their values (Length 1590, Width 1053, Frame Depth 35 mm, Weight 19 kg), one set for all three models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Mechanical Specifications
Printed as "Rated Power, Watts (Pmax) 320 315 310" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Printed in the electrical specifications table of Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), column 2 of 3 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN320KA01 VBHN315KA01 VBHN310KA01"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Where: Page 2 Electrical Specifications, Series Fuse Rating
The modules should be mounted at the four (4) quarter points by the means shown in Figure 2.; This method offers a maximum load of 2,400 N/m2 (50PSF) in a static state on the module surface.; Fixing span must be between 1030-1230mm
Printed as "The modules should be mounted at the four (4) quarter points by the means shown in Figure 2." and "This method offers a maximum load of 2,400 N/m2 (50PSF) in a static state on the module surface." under Mechanical Loading in Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), and "Fixing span must be between 1030-1230mm" in the note to Figure 2 (PDF page 11). The manual does not say whether this maximum load is a test or a design load, so it is kept here and not as a front or rear load.
Where: PDF page 5, Mechanical Loading, and PDF page 11, Figure 2
Printed as "Maximum series fuse (A) 15 15 15" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column.
Where: PDF page 11, Specifications table, Maximum series fuse (A) row, VBHN315KA01 column
Printed as "Maximum System Voltage 600 600 600" in the specifications table of Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), whose header reads "Model VBHN320KA01 VBHN315KA01 VBHN310KA01"; VBHN315KA01 is the second column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Where: PDF page 11, Specifications table, Maximum System Voltage row, VBHN315KA01 column
Printed in the electrical specifications table of Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), column 2 of 3 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN320KA01 VBHN315KA01 VBHN310KA01"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Printed as "The operating temperature must be within –40°C (-40 °F) to 85°C (185 °F)." under Operating Conditions in Panasonic's General Installation Manual Photovoltaic Module HIT VBHNxxxKA01 series (3rd Edition, 2017.9.20), a statement for all the models it covers. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Panasonic (web.archive.org), which stays listed as an additional source.
Printed as "Safety & Rating Certifications UL 1703, cUL, CEC" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), read on September 25, 2026. UL 1703 is recorded as a certification claim; the other entries are marks, listings or management-system standards printed on the same line, with no certificate number, scope or issuer.
Printed in the electrical specifications table of Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), column 2 of 3 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN320KA01 VBHN315KA01 VBHN310KA01"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Where: Page 2 Electrical Specifications, Temperature Coefficient (Pmax)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed in the electrical specifications table of Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), column 2 of 3 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN320KA01 VBHN315KA01 VBHN310KA01"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024). Footnote ** says the installation must be registered at www.panasonicusahitwarranty.com within 60 days to receive the 25-year product workmanship term: "Otherwise, Product Workmanship will be only fifteen (15) years." Read on September 25, 2026.
Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), with footnote "*** 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.
Power temperature coefficient-0.26 %/°C13.6 / 16.0
0.258 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed in the electrical specifications table of Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), column 2 of 3 (the model header reads "ELECTRICAL SPECIFICATIONS Model VBHN320KA01 VBHN315KA01 VBHN310KA01"), under the footnoted test condition "STC: Cell temp. 25°C, AM1.5, 1000W/m²"; read on September 25, 2026.
0.06032 kg per W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 0.01227 kg per W, the lowest documented for a solar panel, calculated from maker figures: Go Power! 110-Watt Solar Flex™ Module
19 kg / 315 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
The maker's documents disagree; the less favorable printed figure, 0.06032 kg per W, is scored. Warning: Panasonic's installation manual and Panasonic's data sheet differ for this field.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1703manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
VBHN315KA01
Limitations
Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024) prints "Safety & Rating Certifications UL 1703, cUL, CEC" and "UL 1703 Fire Classification Type 2" in its Operating Conditions & Safety Ratings table for VBHN315KA01. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Printed as "Power output is guaranteed to 90.76% after 25 years" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), read on September 25, 2026; the percentage is the rated power output warranted at year 25.
Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024). Footnote ** says the installation must be registered at www.panasonicusahitwarranty.com within 60 days to receive the 25-year product workmanship term: "Otherwise, Product Workmanship will be only fifteen (15) years." Read on September 25, 2026.
Printed as "*** 1st year 97%, after 2nd year 0.26% annual degradation to year 25." in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), the warranted yearly decline from year 2 to year 25; the first-year figure is 97% of rated power. Read on September 25, 2026.
Printed as "Limited Warranty 25** Yrs Workmanship and Power Output (Linear)***" in Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024), with footnote "*** 1st year 97%, after 2nd year 0.26% annual degradation to year 25." Read on September 25, 2026.
Internet Archive copy dated January 20, 2022 (the archive's own date); read on October 1, 2026.
Location: PDF page 1 (model list) and PDF page 11 (specifications)
Retrieved Oct 1, 2026
Panasonic's own installation manual for its HIT VBHNxxxKA01 modules (VBHN320KA01, VBHN315KA01, VBHN310KA01), originally at https://ftp.panasonic.com/solar/installation/manual_for_black_hit_module_installation.pdf, as linked from Panasonic's 2019 product pages. Revision history ends with the 3rd Edition of 2017.9.20. North American edition (UL 1703, NEC). Prints per-model electrical ratings on PDF page 11; the rest is series-level instruction. Panasonic's own host ftp.panasonic.com disallows all robots, so this is an archived copy: the Internet Archive captured Panasonic's own file on 20 January 2022, and that archived copy was read on 1 October 2026. It is labeled as an archived copy, not a current download from Panasonic. Manufacturer instructions, not independent tests.
UL 1703Manufacturer claim · equipment listingClaimedListed when checked
Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024) prints "Safety & Rating Certifications UL 1703, cUL, CEC" and "UL 1703 Fire Classification Type 2" in its Operating Conditions & Safety Ratings table for VBHN315KA01. Recorded exactly as Panasonic prints it, read on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Internet Archive copy of Panasonic's own datasheet PDF at https://ftp.panasonic.com/solar/datasheet/n320k_n315k_n310k_datasheet.pdf, captured on June 15, 2024 and read on September 25, 2026; not a live manufacturer document. Panasonic's document host disallows automated access, so the archived copy is used. The datasheet carries Panasonic's revision code RS17170K.
Archived copies
Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Product heading, model line and Product details
Retrieved Sep 24, 2026
Internet Archive copy of Panasonic's own product page at https://na.panasonic.com/us/energy-solutions/solar/hitr-black-series/n315k-photovoltaic-module-hitr-black, captured on August 21, 2019 and read on September 25, 2026; not a live page. Panasonic's product pages for these modules are no longer published.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Panasonic HIT Black N320K/N315K/N310K datasheet (VBHN320KA01, VBHN315KA01, VBHN310KA01) (Internet Archive copy, June 15, 2024)
Archived copy of a document published by Panasonic. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: 0.0603
unit: Unknown
shown: 19 kg / 315 W
shown detail: Unknown
state: documented
points: 1
ceiling: 5
weight: 5
share: 20.3
covered: yes
missing: no
folded: no
reason: documents-disagree
reason text: The maker's documents disagree; the less favorable printed figure, 0.06032 kg per W, is scored. Warning: Panasonic's installation manual and Panasonic's data sheet differ for this field.