Mission Solar Energy MSE415SX6Z

By Mission Solar EnergySKU not documented

Solar panelCEC listed
No owner reviews yet · Write the first

Key specs

Units
Rated output (STC)
415 W
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Power output (Pmax), MSE415SX6Z column

Documented

Module efficiency
18.9 %
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Module efficiency, MSE415SX6Z column

Documented

Voltage at max power (Vmp)
40.09 V
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Rated voltage (Vmp), MSE415SX6Z column

Documented

Current at max power (Imp)
10.35 A
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Rated current (Imp), MSE415SX6Z column

Documented

Open-circuit voltage (Voc)
48.91 V
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Open-circuit voltage (Voc), MSE415SX6Z column

Documented

Short-circuit current (Isc)
10.91 A
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Short-circuit current (Isc), MSE415SX6Z column

Documented

Power temperature coefficient
-0.36 %/°C
Official datasheet
Sources

Read from Mission Solar Energy's published document at https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf, from the only model this document publishes, MSE415SX6Z. Printed value: "-0.359%/°C". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official datasheet: Mission Solar Energy datasheet Checked · Earlier document

Location: PDF page 2, "Temperature Coefficient of Pmax" row

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Read from the publisher's own document for this exact model (Page 2, operating conditions, Maximum System Voltage). The publisher prints no further test condition for this row; no value was taken from another model.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, operating conditions, Maximum System Voltage

Documented

All specs23
Rated output (STC)
415 W
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Power output (Pmax), MSE415SX6Z column

Documented

Module efficiency
18.9 %
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Module efficiency, MSE415SX6Z column

Documented

Voltage at max power (Vmp)
40.09 V
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Rated voltage (Vmp), MSE415SX6Z column

Documented

Current at max power (Imp)
10.35 A
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Rated current (Imp), MSE415SX6Z column

Documented

Open-circuit voltage (Voc)
48.91 V
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Open-circuit voltage (Voc), MSE415SX6Z column

Documented

Short-circuit current (Isc)
10.91 A
Official datasheet
Sources

Front-side STC: 1,000 W/m², AM1.5, cell temperature 25 °C; any rear-side bifacial gain excluded.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, electrical specification table, Short-circuit current (Isc), MSE415SX6Z column

Documented

Power temperature coefficient
-0.36 %/°C
Official datasheet
Sources

Read from Mission Solar Energy's published document at https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf, from the only model this document publishes, MSE415SX6Z. Printed value: "-0.359%/°C". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official datasheet: Mission Solar Energy datasheet Checked · Earlier document

Location: PDF page 2, "Temperature Coefficient of Pmax" row

Documented

Maximum system voltage
1,500 V
Official datasheet
Sources

Read from the publisher's own document for this exact model (Page 2, operating conditions, Maximum System Voltage). The publisher prints no further test condition for this row; no value was taken from another model.

Official datasheet: Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z) Checked · Earlier document

Location: Page 2, operating conditions, Maximum System Voltage

Documented

Published claims and calculations, not independent test results.

Documents

3 on file
  • PDF
    Mission Solar MSE PERC 72 410-420 W datasheet (C-SA2-MKTG-0028, SX6Z)OfficialMission Solar EnergyOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Page 2, electrical specification table

    Retrieved

    Manufacturer datasheet for the MSExxxSX6Z family; it names 410 W, 415 W and 420 W columns only.

    Archived copies

    Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 2.03 MB

    Archived copy, unaltered, kept as a record of what Mission Solar Energy published. Original address: https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 74acd0d30465a213ce438793dedf4aa43f48c8fc7f0aff0ed233bf1c51a1e988

    Open
  • PDF
    Module Installation and User Manual, M6 Series (P-SA2-UM-0009)OfficialMission Solar EnergyOfficial instruction manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Document, page 1

    Retrieved

    Installation, handling and safety requirements for the MSE M6 series; it does not establish per-model electrical ratings.

    Archived copies

    Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 4.71 MB

    Archived copy, unaltered, kept as a record of what Mission Solar Energy published. Original address: https://www.missionsolar.com/wp-content/uploads/2025/05/P-SA2-UM-0009-Module-Installation-and-User-Manual-for-M6-Series.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    18

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 9b015dae210d067ece867f86d3ea1a265b100d29e83ba130d78fac8b71c333cb

    Open
  • PDF
    MSE PV Module Limited Warranty (C-CTA-0017)OfficialMission Solar EnergyOfficial warranty
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Document, page 1

    Retrieved

    Limited product and power warranty terms for the MSE module line; durations depend on module manufacturing date and it publishes no electrical specifications.

    Archived copies

    Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.15 MB

    Archived copy, unaltered, kept as a record of what Mission Solar Energy published. Original address: https://www.missionsolar.com/wp-content/uploads/2025/05/C-CTA-0017-MSE-PV-Module-Limited-Warranty-MSE-LLC-2.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    4

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6b0c2af70d821952b91ff753766ab60de4be9a4c82c45ec4531f6df730bd852e

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Mission Solar Energy datasheet

Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 2.03 MB

Archived copy, unaltered, kept as a record of what Mission Solar Energy published. Original address: https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Mar 22, 2022
Embedded modification date
Mar 22, 2022

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 74acd0d30465a213ce438793dedf4aa43f48c8fc7f0aff0ed233bf1c51a1e988

MSE PV Module Limited Warranty (C-CTA-0017)

Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.15 MB

Archived copy, unaltered, kept as a record of what Mission Solar Energy published. Original address: https://www.missionsolar.com/wp-content/uploads/2025/05/C-CTA-0017-MSE-PV-Module-Limited-Warranty-MSE-LLC-2.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
4

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6b0c2af70d821952b91ff753766ab60de4be9a4c82c45ec4531f6df730bd852e

Module Installation and User Manual, M6 Series (P-SA2-UM-0009)

Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 4.71 MB

Archived copy, unaltered, kept as a record of what Mission Solar Energy published. Original address: https://www.missionsolar.com/wp-content/uploads/2025/05/P-SA2-UM-0009-Module-Installation-and-User-Manual-for-M6-Series.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
18

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 9b015dae210d067ece867f86d3ea1a265b100d29e83ba130d78fac8b71c333cb

Submit a document

Warranty

Product warranty
25 years
Official warranty
Sources

MSE limited warranty: 25-year product cover applies to modules manufactured on or after 1 August 2019 (12 years before that date); 25-year limited power warranty.

Official warranty: MSE PV Module Limited Warranty (C-CTA-0017) Checked · Earlier document

Location: Section 2, Limited Product Warranty

Documented

Power warranty
25 years
Official warranty
Sources

MSE limited warranty: 25-year product cover applies to modules manufactured on or after 1 August 2019 (12 years before that date); 25-year limited power warranty.

Official warranty: MSE PV Module Limited Warranty (C-CTA-0017) Checked · Earlier document

Location: Section 3, Limited Power Warranty

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

64/10084% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Power temperature coefficient-0.36 %/°C9.8 / 16.0

0.359 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Read from Mission Solar Energy's published document at https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf, from the only model this document publishes, MSE415SX6Z. Printed value: "-0.359%/°C". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.

Official datasheet: Mission Solar Energy datasheet Checked · Earlier document

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

3 on fileCEC listed
UL 61730Product / system scope unresolvedClaimedStatus unconfirmed

Mission Solar Energy prints "UL 61730" in a certification, standards or compliance row on PDF page 2 of https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf, a document this catalog already attaches to MSE415SX6Z; the value was located through a page that names MSE415SX6Z and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Models: MSE415SX6Z

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official datasheet: Mission Solar Energy datasheet Checked · Earlier document
UL 61730Product / system scope unresolvedClaimedListed when checked

Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Mission Solar Energy LLC "MSE415SX6Z": UL 61730, certifying entity not printed on the list, CEC listing date 2021-05-21. A state equipment list entry, not the certification body's own record.

Models: MSE415SX6Z

Issued
Not stated
Valid from
May 21, 2021
Expiry
Not stated
Issuer checked
Not checked
Issuer record: CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) October 1, 2026 · Checked · Earlier document
CECProduct / system scope unresolvedClaimedListed when checked

Model MSE415SX6Z listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Mission Solar Energy LLC, as "MSE415SX6Z", CEC listing date 2021-05-21. This is an equipment listing, not UL certification or complete-system approval.

Models: MSE415SX6Z

Issued
Not stated
Valid from
May 21, 2021
Expiry
Not stated
Issuer checked
Not checked
Issuer record: CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) October 1, 2026 · Checked · Earlier document
Datasheet & manual claims1
UL 61730Manufacturer claim · equipment listingClaimedStatus unconfirmed

Mission Solar Energy prints "UL 61730" in a certification, standards or compliance row on PDF page 2 of https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf, a document this catalog already attaches to MSE415SX6Z; the value was located through a page that names MSE415SX6Z and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Manufacturer document

Official datasheet: Mission Solar Energy datasheet Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
MSE415SX6Z

UL 61730: claimed

Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Mission Solar Energy LLC "MSE415SX6Z": UL 61730, certifying entity not printed on the list, CEC listing date 2021-05-21. A state equipment list entry, not the certification body's own record.

Issuer record: CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) October 1, 2026 · Checked · Earlier document

CEC: claimed

Product / system scope unresolved. Model MSE415SX6Z listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Mission Solar Energy LLC, as "MSE415SX6Z", CEC listing date 2021-05-21. This is an equipment listing, not UL certification or complete-system approval.

Issuer record: CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) October 1, 2026 · Checked · Earlier document

UL 61730: claimed

Product / system scope unresolved. Mission Solar Energy prints "UL 61730" in a certification, standards or compliance row on PDF page 2 of https://www.missionsolar.com/wp-content/uploads/2025/05/C-SA2-MKTG-0028-Data-Sheet-for-SX6Z.pdf, a document this catalog already attaches to MSE415SX6Z; the value was located through a page that names MSE415SX6Z and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

Official datasheet: Mission Solar Energy datasheet Checked · Earlier document

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.