Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Current at Rated Power, Impp (A) column reads 6.06. Electrical parameters are measured at Standard Test Conditions. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Where: Table 1 (Electrical characteristics), SPR-X21-470-COM row, Current at Rated Power, Impp (A) column
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Short Circuit Current, Isc (A) +/-3% column reads 6.45. Electrical parameters are measured at Standard Test Conditions. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Voltage at Rated Power Vmpp (V) column reads 77.6. Electrical parameters are measured at Standard Test Conditions. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Where: Table 1 (Electrical characteristics), SPR-X21-470-COM row, Voltage at Rated Power Vmpp (V) column
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Open Circuit Voltage Voc (V) +/-3% column reads 91.5. Electrical parameters are measured at Standard Test Conditions. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Where: Table 1 (Electrical characteristics), SPR-X21-470-COM row, Open Circuit Voltage Voc (V) +/-3% column
Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025) lists this model under the platform "MAX3 128c SPR-Xyy-XXX-COM xxx=420-485" and titles its drawing "Maxeon 3 128 cells Solar Panel SPR-Xyy-XXX-COM". Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Module Rated Power (W) +5/-0% column reads 470. Electrical parameters are measured at Standard Test Conditions. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025) prints "The maximum series fuse rating is 15A for X-Series"; the document applies to the platform "MAX3 128c SPR-Xyy-XXX-COM xxx=420-485", which includes this model. Revised on 17 October 2026: The fact rested only on an Internet Archive copy, which is not a usable source; Maxeon's own live US installation instructions print the same value, so the fact is re-cited to them (PM, October 17, 2026).
Where: Section 2 (Electrical characteristics), maximum series fuse rating
Maxeon documents print different values. Maxeon's US Safety and Installation Instructions (544753 Rev J) print 1500 V, which is recorded; the manual is the primary source. SunPower's older US datasheet printed 1000 V.
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Maximum System Voltage column reads 1500 (safety class II). Corrected on 17 October 2026: the catalog had published 1000 V from SunPower's earlier US datasheet, which is no longer published; that value stays listed as an alternative. Revised on 17 October 2026: Maxeon's live US installation instructions print a maximum system voltage of 1500 V for this exact model; the earlier 1000 V rested only on an Internet Archive copy (PM, October 17, 2026).
Where: Table 1 (Electrical characteristics), SPR-X21-470-COM row, Maximum System Voltage column
Maxeon documents print different values. Maxeon's US Safety and Installation Instructions (544753 Rev J) print -0.27 %/°C, which is recorded; the manual is the primary source. SunPower's older US datasheet printed -0.29 %/°C.
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Power Temp. Coeff. %/°C column reads -0.27. Corrected on 17 October 2026: the catalog had published -0.29 %/°C from SunPower's earlier US datasheet, which is no longer published; that value stays listed as an alternative. Revised on 17 October 2026: Maxeon's live US installation instructions print -0.27 %/°C for this exact model; the earlier -0.29 %/°C rested only on an Internet Archive copy (PM, October 17, 2026).
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
0.29 %/°C is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 0.22 %/°C, the lowest documented for a solar panel, printed by the maker: Jackery SolarSaga 100 Air
Printed in Table 1 of Maxeon's Safety and Installation Instructions (United States), document 544753 Rev J (December 2025), row "SPR-X21-470-COM 470 77.6 6.06 91.5 6.45 0.058 -0.236 -0.27 1500 II"; the Power Temp. Coeff. %/°C column reads -0.27. Corrected on 17 October 2026: the catalog had published -0.29 %/°C from SunPower's earlier US datasheet, which is no longer published; that value stays listed as an alternative. Revised on 17 October 2026: Maxeon's live US installation instructions print -0.27 %/°C for this exact model; the earlier -0.29 %/°C rested only on an Internet Archive copy (PM, October 17, 2026).
The maker's documents disagree; the less favorable printed figure, 0.29 %/°C, is scored. Warning: Maxeon documents print different values
UL 61730authority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
SPR-X21-470-COM
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Maxeon Solar Technologies Ltd. "SPR-X21-470-COM": UL 61730, certifying entity not printed on the list, CEC listing date 2022-12-12. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
SPR-X21-470-COM
Limitations
Model SPR-X21-470-COM listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Maxeon Solar Technologies Ltd., as "SPR-X21-470-COM", CEC listing date 2022-12-12. This is an equipment listing, not UL certification or complete-system approval.
Maxeon's current US safety and installation instructions for X-Series, MAX3, MAX6 and MAX7 modules, linked from Maxeon's technical documents page (www.maxeon.com); published December 2025. The file is served from Maxeon's site storage (static1.squarespace.com). Manufacturer claims, not an independent test.
Archived copies
Archived copy of a document published by Maxeon Solar Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
manufacturer_document_third_party_hosted: Wayback Machine copy of a maxeon.com/us file the live site no longer serves.
Location: Electrical Data table
Retrieved Sep 26, 2026
A Wayback Machine (archive.org) capture, dated August 5, 2021, of a Maxeon-hosted PDF at a legacy maxeon.com/us file path that no longer serves the file (the live URL now redirects to maxeon.com's homepage). Labeled manufacturer_document_third_party_hosted per this batch's fallback rule: the byte-identical PDF is Maxeon's own publication, only the retrieval host differs. It does not establish independent test results.
Archived copies
Archived copy of a document published by Maxeon Solar Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
File maxeon-001-14158-revai.pdf, 13 pages, collected 2026-09-28 for issue #102.
Location: maxeon-001-14158-revai.pdf
Retrieved Sep 27, 2026
Archived copy of the manufacturer's own document as of 2023-05-23, served byte for byte by the Wayback Machine; collected for issue #102 on 2026-09-28 because the live host is blocked or gone.
SunPower X-Series Commercial DC Panel X21-470-COM and X21-460-COM datasheet (527837 Rev B) (Internet Archive copy, June 24, 2022)
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
SunPower X-Series Commercial Solar Panels X21-470-COM datasheet (524935 Rev B) (Internet Archive copy, October 25, 2021)
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Maxeon X-Series: X21-470-COM commercial DC panel datasheet (527837 Rev B), Wayback Machine copy of a retired maxeon.com/us file path
Archived copy of a document published by Maxeon Solar Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Maxeon Solar Technologies. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SPR-X21-470-COM
Manufacturer SKU SPR-X21-470-COM · US market
Observed Oct 11, 2026
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Maxeon Solar Technologies Ltd. "SPR-X21-470-COM": UL 61730, certifying entity not printed on the list, CEC listing date 2022-12-12. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model SPR-X21-470-COM listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Maxeon Solar Technologies Ltd., as "SPR-X21-470-COM", CEC listing date 2022-12-12. This is an equipment listing, not UL certification or complete-system approval.