locator: Page 2, Electrical Data header row, column 2 of 2
conditions: The model number SunPower printed in the Electrical Data header row of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) ("Electrical Data SPR-X22-360 SPR-X21-345"). The datasheet prints no separate part number.
Printed in the Operating Condition And Mechanical Data block of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), once for every model on the sheet.
Where: Page 2, Operating Condition And Mechanical Data, Frame
Printed in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), column 2 of 2 (the header row prints "Electrical Data SPR-X22-360 SPR-X21-345"); the row prints "Rated Current (Impp) 6.09 A 6.02 A". The table's Nominal Power row carries footnote 7, "7 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C)."; the table prints no other test condition.
Where: Page 2, Electrical Data, Rated Current (Impp), column 2 of 2
Printed in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), column 2 of 2 (the header row prints "Electrical Data SPR-X22-360 SPR-X21-345"); the row prints "Short-Circuit Current (Isc) 6.48 A 6.39 A". The table's Nominal Power row carries footnote 7, "7 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C)."; the table prints no other test condition.
Where: Page 2, Electrical Data, Short-Circuit Current (Isc), column 2 of 2
Printed in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), column 2 of 2 (the header row prints "Electrical Data SPR-X22-360 SPR-X21-345"); the row prints "Rated Voltage (Vmpp) 59.1 V 57.3 V". The table's Nominal Power row carries footnote 7, "7 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C)."; the table prints no other test condition.
Where: Page 2, Electrical Data, Rated Voltage (Vmpp), column 2 of 2
Printed in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), column 2 of 2 (the header row prints "Electrical Data SPR-X22-360 SPR-X21-345"); the row prints "Open-Circuit Voltage (Voc) 69.5 V 68.2 V". The table's Nominal Power row carries footnote 7, "7 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C)."; the table prints no other test condition.
Where: Page 2, Electrical Data, Open-Circuit Voltage (Voc), column 2 of 2
SunPower's X-Series X21-335-BLK and X21-345 datasheet (504828 Rev G) does not use the word "bifacial" or "monofacial" and prints no front/rear power ratio or bifaciality percentage for SPR-X21-345; left unknown rather than inferred from construction.
Printed in the Operating Condition And Mechanical Data block of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), once for every model on the sheet: "Solar Cells 96 Monocrystalline Maxeon Gen III".
Where: Page 2, Operating Condition And Mechanical Data, Solar Cells
Printed in the Operating Condition And Mechanical Data block of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), once for every model on the sheet: "Weight 41 lbs (18.6 kg)".
Where: Page 2, Operating Condition And Mechanical Data, Weight
Printed in the Operating Condition And Mechanical Data block of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), once for every model on the sheet: "Solar Cells 96 Monocrystalline Maxeon Gen III".
Where: Page 2, Operating Condition And Mechanical Data, Solar Cells
Printed as "Glass High-transmission tempered anti-reflective" in Maxeon's SPR-X21-345 datasheet (SunPower X-Series Residential Solar Panels X21-335-BLK and X21-345 datasheet (504828 Rev G) (Internet Archive copy, March 29, 2021)), captured on September 28, 2026.
Printed in the Operating Condition And Mechanical Data block of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), once for every model on the sheet: the panel has a "High-transmission tempered anti-reflective" tempered glass front and a "Class 1 black anodized" frame, so it is recorded as a rigid framed panel.
Where: Page 2, Operating Condition And Mechanical Data, Tempered Glass and Frame
Where: Page 2, Operating Condition And Mechanical Data, Max. Test Load
Sources
3,000 Pa
Design (not test) load; printed in SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) as "Design Load Wind: 62 psf, 3000 Pa, 305 kg/m² back Snow: 125 psf, 6000 Pa, 611 kg/m² front" (the back figure is the wind design load).
W 1,046 × L 1,558 × D 46 mm / W 41.18 × L 61.34 × D 1.8 in converted
Printed as dimension labels on the frame drawing of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021): "1558 mm [61.3 in]", "1046 mm [41.2 in]" and "46 mm [1.8 in]"; the drawing also labels a 30 mm [1.2 in] frame profile dimension. Length, width and depth are assigned from the drawing's long side, short side and frame depth labels.
Where: Page 2, Operating Condition And Mechanical Data, Max. Test Load
Sources
6,000 Pa
Design (not test) load; printed in SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) as "Design Load Wind: 62 psf, 3000 Pa, 305 kg/m² back Snow: 125 psf, 6000 Pa, 611 kg/m² front" (the front figure is the snow design load).
Printed in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), column 2 of 2 (the header row prints "Electrical Data SPR-X22-360 SPR-X21-345"); the row prints "Nominal Power (Pnom) 7 360 W 345 W". The table's Nominal Power row carries footnote 7, "7 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C)."; the table prints no other test condition. Power Tolerance is printed as "+5/0%".
Where: Page 2, Electrical Data, Nominal Power (Pnom), column 2 of 2
Printed once for every model in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021).
Where: Page 2, Electrical Data, Maximum Series Fuse
Printed in the Operating Condition And Mechanical Data block of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), once for every model on the sheet: "Temperature −40° F to +185° F (−40° C to +85° C)".
Where: Page 2, Operating Condition And Mechanical Data, Temperature
Printed once for every model in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) as "Power Temp Coef. −0.29% / o C" (the extracted text renders the degree sign as "o"). The same table prints Voltage Temp Coef. and Current Temp Coef. only in mV/°C and mA/°C, so no percentage Voc or Isc coefficient is recorded.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Page 1 of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) states "we stand behind our panel with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar". The datasheet prints no warranty terms, claimant or year-by-year power figure.
Page 1 of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) states "we stand behind our panel with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar". The datasheet prints no warranty terms, claimant or year-by-year power figure.
Power temperature coefficient-0.29 %/°C12.1 / 16.0
0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed once for every model in the Electrical Data table of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) as "Power Temp Coef. −0.29% / o C" (the extracted text renders the degree sign as "o"). The same table prints Voltage Temp Coef. and Current Temp Coef. only in mV/°C and mA/°C, so no percentage Voc or Isc coefficient is recorded.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 61215manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
SPR-X21-345
Limitations
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730" under Tests And Certifications, Standard Tests. Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 61701manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
SPR-X21-345
Limitations
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "Salt Spray Test IEC 61701 (maximum severity)" under Tests And Certifications as "Salt Spray Test IEC 61701 (maximum severity)". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 61730manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
SPR-X21-345
Limitations
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730" under Tests And Certifications, Standard Tests. Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 62716manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
SPR-X21-345
Limitations
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "Ammonia Test IEC 62716" under Tests And Certifications as "Ammonia Test IEC 62716". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 62804manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
SPR-X21-345
Limitations
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "PID Test 1000 V: IEC 62804, PVEL 600 hr duration" under Tests And Certifications as "PID Test 1000 V: IEC 62804, PVEL 600 hr duration". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
MIL-STD-810Gmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
SPR-X21-345
Limitations
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "Desert Test MIL-STD-810G" under Tests And Certifications as "Desert Test MIL-STD-810G". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "UL1703 (Type 2 Fire Rating)" under Tests And Certifications, Standard Tests, with footnote 8 "Type 2 fire rating per UL1703:2013, Class C fire rating per UL1703:2002". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
Page 1 of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) states "we stand behind our panel with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar". The datasheet prints no warranty terms, claimant or year-by-year power figure.
Page 1 of SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021) states "we stand behind our panel with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar". The datasheet prints no warranty terms, claimant or year-by-year power figure.
File maxeon-001-14158-revai.pdf, 13 pages, collected 2026-09-28 for issue #102.
Location: maxeon-001-14158-revai.pdf
Retrieved Sep 27, 2026
Archived copy of the manufacturer's own document as of 2023-05-23, served byte for byte by the Wayback Machine; collected for issue #102 on 2026-09-28 because the live host is blocked or gone.
UL1703Manufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "UL1703 (Type 2 Fire Rating)" under Tests And Certifications, Standard Tests, with footnote 8 "Type 2 fire rating per UL1703:2013, Class C fire rating per UL1703:2002". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 61215Manufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730" under Tests And Certifications, Standard Tests. Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 61730Manufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "UL1703 (Type 2 Fire Rating), IEC 61215, IEC 61730" under Tests And Certifications, Standard Tests. Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 62716Manufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "Ammonia Test IEC 62716" under Tests And Certifications as "Ammonia Test IEC 62716". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
MIL-STD-810GManufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "Desert Test MIL-STD-810G" under Tests And Certifications as "Desert Test MIL-STD-810G". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 61701Manufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "Salt Spray Test IEC 61701 (maximum severity)" under Tests And Certifications as "Salt Spray Test IEC 61701 (maximum severity)". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
IEC 62804Manufacturer claim · equipment listingClaimedListed when checked
SunPower's X-Series datasheet 527980 Rev C / LTR_US (Publication Date: June 2020; Internet Archive copy captured December 6, 2021), which covers SPR-X21-345, prints "PID Test 1000 V: IEC 62804, PVEL 600 hr duration" under Tests And Certifications as "PID Test 1000 V: IEC 62804, PVEL 600 hr duration". Recorded as the manufacturer printed it; the document is an Internet Archive copy retrieved on September 25, 2026. No issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified. The same block prints "Available Listings UL, TUV, MCS, FSEC, CEC".
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Page 2: Electrical Data table; Operating Condition And Mechanical Data; Tests And Certifications; footnotes 7 to 9
Retrieved Sep 24, 2026
Internet Archive copy of the datasheet SunPower Corporation published at https://us.sunpower.com/sites/default/files/sp-x22-360-345-ds-en-ltr-pv4s-527980c.pdf, captured by the Internet Archive on December 6, 2021 and retrieved on September 25, 2026; not a live manufacturer document (the original address answered HTTP 404 on September 25, 2026). The document prints "527980 Rev C / LTR_US" and "Publication Date: June 2020" and is published under the SunPower name, with SunPower Corporation as copyright holder. Figures describe the panel as documented in that revision.
Archived copies
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
SunPower X-Series: X22-360 SunPower Residential DC Panel datasheet (527980 Rev C) (Internet Archive copy, December 6, 2021)
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
SunPower X-Series Residential Solar Panels X21-335-BLK and X21-345 datasheet (504828 Rev G) (Internet Archive copy, March 29, 2021)
Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].