locator: Page 2, Electrical parameters at STC, TYPE row
conditions: The TYPE row prints "JAM72S10" above "-410/MR" in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the text layer reads "JAM72S10 -410/MR".
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2.
Where: Page 2, Electrical parameters at STC, Maximum Power Current(Imp) row, JAM72S10-410/MR column
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2.
Where: Page 2, Electrical parameters at STC, Short Circuit Current(Isc) row, JAM72S10-410/MR column
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2.
Where: Page 2, Electrical parameters at STC, Maximum Power Voltage(Vmp) row, JAM72S10-410/MR column
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2.
Where: Page 2, Electrical parameters at STC, Open Circuit Voltage(Voc) row, JAM72S10-410/MR column
Printed as "144(6×24)" in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A), read from the rendered page; the text layer runs the two figures together as "1446×24".
Printed in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); cable length (including connector) printed as "Portrait: 300mm(+)/400mm(-); Landscape: 1200mm(+)/1200mm(-)".
A framed module with mounting and grounding holes, as drawn in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A) (frame depth 40±1 mm).
Printed as "5400Pa" in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A). The footnote says that for NexTracker installations the static load measures 2400Pa front and 2400Pa back.
Where: Page 2, Operating conditions, Maximum Static Load (Front)
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2. The power tolerance is printed as 0~+5W.
Where: Page 2, Electrical parameters at STC, Rated Maximum Power(Pmax) row, JAM72S10-410/MR column
Printed as "1000V/1500V DC(IEC)" in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); recorded as printed because the datasheet gives two figures without saying which applies to a given module.
Where: Page 2, Operating conditions, Maximum System Voltage
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the JAM72S10-410/MR column of the ELECTRICAL PARAMETERS AT STC table (irradiance 1000W/m², cell temperature 25℃, AM1.5G) in the JA Solar JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A); the column's values print "410 50.12 41.88 10.45 9.79 20.4" in the order rated maximum power, open circuit voltage, maximum power voltage, short circuit current, maximum power current, module efficiency, checked against the rendered page 2.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 61215manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
JAM72S10 390-410/MR Series
Limitations
JA Solar's JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A) lists "IEC 61215, IEC 61730" under Comprehensive Certificates for the series, which includes JAM72S10-410/MR. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
IEC 61730manufacturer claimpresent at observation[1]
Scope
unresolved document set
Covered models
JAM72S10 390-410/MR Series
Limitations
JA Solar's JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A) lists "IEC 61215, IEC 61730" under Comprehensive Certificates for the series, which includes JAM72S10-410/MR. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
CECauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
JAM72S10-410/MR
Limitations
Model JAM72S10-410/MR listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under JA Solar, as "JAM72S10-410/MR", CEC listing date 2020-12-21. This is an equipment listing, not UL certification or complete-system approval.
IEC 61215Manufacturer claim · unresolved document setClaimedListed when checked
JA Solar's JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A) lists "IEC 61215, IEC 61730" under Comprehensive Certificates for the series, which includes JAM72S10-410/MR. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
IEC 61730Manufacturer claim · unresolved document setClaimedListed when checked
JA Solar's JAM72S10 390-410/MR Series datasheet (Global_EN_20190703A) lists "IEC 61215, IEC 61730" under Comprehensive Certificates for the series, which includes JAM72S10-410/MR. Recorded as the manufacturer prints it; no issuer record or certificate was read, so the claim is not issuer-verified.
Location: Page 2, Specifications, Electrical parameters at STC, Operating conditions
Retrieved Oct 2, 2026
JA Solar's two-page global English datasheet for the JAM72S10 390-410/MR Series (version Global_EN_20190703A), on jasolar.com, captured October 2, 2026. Electrical figures are read from each model's column of the ELECTRICAL PARAMETERS AT STC table; in the text layer the 410/MR column is printed after the other columns, so the columns were matched on the rendered page 2. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by JA Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
JAM72S10 390-410/MR Series datasheet, Global_EN_20190703A
Archived copy of a document published by JA Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
JAM72S10-410/MR
Manufacturer SKU JAM72S10-410/MR
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model JAM72S10-410/MR listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under JA Solar, as "JAM72S10-410/MR", CEC listing date 2020-12-21. This is an equipment listing, not UL certification or complete-system approval.