Charged ReviewsSaved 0Compare 0Login

Hyundai Energy Solutions HIS-T640NJ

Key specs

BrandHyundai Energy Solutions
ModelHIS-T640NJ
Rated power640 W
Cell typeN-Type TOPCon
Module efficiency22.9 %
Open-circuit voltage57.77 V Check note
Short-circuit current14.06 A Check note
DimensionsW 1,134 × L 2,465 × D 30 mm / W 44.65 × L 97.05 × D 1.2 in converted
Weight34.7 kg / 76.5 lb converted
Product warranty12 years
Power warranty30 years

All specifications

Show all 29 specifications

Identity

BrandHyundai Energy Solutions · Website
ModelHIS-T640NJ
MarketUnknown
Manufacturer SKUHIS-T640NJ Provisional
SKU detail
locator: Part number
conditions: Seller-listed specification; not independently verified.
Sources: [1]
FieldValueConditionsSource
FrameAnodized aluminum alloy
Printed as "Frame Anodized aluminum alloy" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026.
Where: Mechanical Characteristics, "Frame" row
[2]
Current at max power13.41 A Check note
Manufacturer source conflict. The current HD Hyundai HiS-T635/640/645NJ datasheet (26.09.10) prints 13.41 A; the earlier preliminary HiS-T630/635/640NJ datasheet printed 13.68 A.
Printed as "14.06 15.58 47.74 47.81 13.41 14.77" in HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), Datasheet PDF page 2, Electrical Characteristics, "Current at Pmax (Impp)" row, HiS-T640NJ column (STC, not BNPI). Revised on 1 October 2026: The current HD Hyundai NJ series datasheet (26.09.10) prints 13.41 A for the HiS-T640NJ; an earlier preliminary datasheet printed 13.68 A, which is kept as an alternative.
Where: Datasheet PDF page 2, Electrical Characteristics, "Current at Pmax (Impp)" row, HiS-T640NJ column (STC, not BNPI)
Sources
13.68 A

Read from the datasheet this catalog row already cites, at https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, from the Standard Test Conditions block of the table whose power classes are 630 | 695 | 635 | 700 | 640 | 705; the 640 column is the one the catalog model HIS-T640NJ names. Printed value: "13.68". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.

[3]
[2]
Short-circuit current14.06 A Check note
Manufacturer source conflict. The current HD Hyundai HiS-T635/640/645NJ datasheet (26.09.10) prints 14.06 A; the earlier preliminary HiS-T630/635/640NJ datasheet printed 14.35 A.
Printed as "14.06 15.58 47.74 47.81 13.41 14.77" in HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), Datasheet PDF page 2, Electrical Characteristics, "Short circuit current (Isc)" row, HiS-T640NJ column (STC, not BNPI). Revised on 1 October 2026: The current HD Hyundai NJ series datasheet (26.09.10) prints 14.06 A for the HiS-T640NJ; an earlier preliminary datasheet printed 14.35 A, which is kept as an alternative.
Where: Datasheet PDF page 2, Electrical Characteristics, "Short circuit current (Isc)" row, HiS-T640NJ column (STC, not BNPI)
Sources
14.35 A

Read from the datasheet this catalog row already cites, at https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, from the Standard Test Conditions block of the table whose power classes are 630 | 695 | 635 | 700 | 640 | 705; the 640 column is the one the catalog model HIS-T640NJ names. Printed value: "14.35". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.

[3]
[2]
Voltage at max power47.74 V Check note
Manufacturer source conflict. The current HD Hyundai HiS-T635/640/645NJ datasheet (26.09.10) prints 47.74 V; the earlier preliminary HiS-T630/635/640NJ datasheet printed 46.79 V.
Printed as "14.06 15.58 47.74 47.81 13.41 14.77" in HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), Datasheet PDF page 2, Electrical Characteristics, "Voltage at Pmax (Vmpp)" row, HiS-T640NJ column (STC, not BNPI). Revised on 1 October 2026: The current HD Hyundai NJ series datasheet (26.09.10) prints 47.74 V for the HiS-T640NJ; an earlier preliminary datasheet printed 46.79 V, which is kept as an alternative.
Where: Datasheet PDF page 2, Electrical Characteristics, "Voltage at Pmax (Vmpp)" row, HiS-T640NJ column (STC, not BNPI)
Sources
46.79 V

Read from the datasheet this catalog row already cites, at https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, from the Standard Test Conditions block of the table whose power classes are 630 | 695 | 635 | 700 | 640 | 705; the 640 column is the one the catalog model HIS-T640NJ names. Printed value: "46.79". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.

[3]
[2]
Open-circuit voltage57.77 V Check note
Manufacturer source conflict. The current HD Hyundai HiS-T635/640/645NJ datasheet (26.09.10) prints 57.77 V; the earlier preliminary HiS-T630/635/640NJ datasheet printed 56.61 V.
Printed as "Open circuit voltage (Voc) V 57.56 57.78 57.77 57.99" in HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), Datasheet PDF page 2, Electrical Characteristics, "Open circuit voltage (Voc)" row, HiS-T640NJ column (STC, not BNPI). Revised on 1 October 2026: The current HD Hyundai NJ series datasheet (26.09.10) prints 57.77 V for the HiS-T640NJ; an earlier preliminary datasheet printed 56.61 V, which is kept as an alternative.
Where: Datasheet PDF page 2, Electrical Characteristics, "Open circuit voltage (Voc)" row, HiS-T640NJ column (STC, not BNPI)
Sources
56.61 V

Read from the datasheet this catalog row already cites, at https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, from the Standard Test Conditions block of the table whose power classes are 630 | 695 | 635 | 700 | 640 | 705; the 640 column is the one the catalog model HIS-T640NJ names. Printed value: "56.61". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.

[3]
[2]
Noct41 °C / 106 °F converted
Printed as "Nominal Module Operation Temperature 41℃ ± 2℃" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026. The tolerance is ± 2℃.
Where: "Nominal Module Operation Temperature" row
[2]
Bifacialyes
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1; the Solar Cells row prints "N-Type TOPCon, 156 (6x26) monocrystalline 16BB half-cut bifacial cells", the Electrical Characteristics table prints "Bifaciality % 80±5" and a BNPI sub-column for every model. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, "Solar Cells" and "Bifaciality" rows
[2] [1]
Cell typeN-Type TOPCon
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1, Mechanical Characteristics; printed "Solar Cells N-Type TOPCon, 156 (6x26) monocrystalline 16BB half-cut bifacial cells". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, Mechanical Characteristics, "Solar Cells" row
[2] [1]
Weight34.7 kg / 76.5 lb converted
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1, Mechanical Characteristics; printed "Weight 34.7 kg (76.5lbs)". Corrected on 25 September 2026: the catalog had published 34.6998 kg, cited to Greentech Renewables (greentechrenewables.com). The earlier 34.6998 kg is the seller's conversion of the printed 76.5 lb; HD Hyundai prints 34.7 kg. Earlier note: "Seller-listed specification; not independently verified."
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, Mechanical Characteristics, "Weight" row
[2]
Cell count156 cells
Printed as "Solar Cells N-Type TOPCon, 156 (6x26) monocrystalline 16BB half-cut bifacial cells" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026.
Where: Mechanical Characteristics, "Solar Cells" row
[2]
Front glass2.0mm(0.08in) semi-tempered solar glass with high transmittance and anti-reflective coating
Printed as "Front : 2.0mm(0.08in) semi-tempered solar glass with high transmittance and anti-reflective coating" in Hyundai Energy Solutions' HiS-TxxxNJ 635-645W datasheet, captured on September 28, 2026.
Where: Datasheet page 1, Front row
[2]
Rear load pa2,400 Pa
Printed as "Maximum Test Load Front 5,400Pa Rear 2,400Pa" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026. A test load; the installation manual sets the design loads by mounting method.
Where: "Maximum Test Load" row
[2]
Rear surface2.0mm(0.08in) semi-tempered solar glass
Printed as "Rear : 2.0mm(0.08in) semi-tempered solar glass" in Hyundai Energy Solutions' HiS-TxxxNJ 635-645W datasheet, captured on September 28, 2026.
Where: Datasheet page 1, Rear row
[2]
DimensionsW 1,134 × L 2,465 × D 30 mm / W 44.65 × L 97.05 × D 1.2 in converted
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1, Mechanical Characteristics; printed "Dimensions 2,465mm (L) x 1,134mm (W) x 30mm (H)"; the record lists the 2465 mm figure as length, 1134 mm as width and the 30 mm frame height as depth. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, Mechanical Characteristics, "Dimensions" row
[2] [1]
Front load pa5,400 Pa
Printed as "Maximum Test Load Front 5,400Pa Rear 2,400Pa" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026. A test load; the installation manual sets the design loads by mounting method.
Where: "Maximum Test Load" row
[2]
Rated power640 W
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiS-T640NJ column (column 2 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Nominal output (Pmax) W 635 701 640 706 645 711"; the HiS-T640NJ STC figure is 640 W. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, Electrical Characteristics table, HiS-T640NJ column, "Nominal output (Pmax)" row
[2] [1]
Series fuse30 A ProvisionalSeller-listed specification; not independently verified.
Where: series-fuse-rating
[1]
Enclosure ratingIP68 (junction box)
Printed as "Junction Box 3-part, 3 bypass diodes, IP68 rated" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026.
Where: Mechanical Characteristics, "Junction Box" row
[2]
Max system voltage1,500 V
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1; printed once for the whole series: "Maximum System Voltage DC 1,500 V". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, "Maximum System Voltage" row
[2] [1]
Module efficiency22.9 %
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiS-T640NJ column (column 2 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Module efficiency % 22.72 22.90 23.07"; the HiS-T640NJ figure is 22.90 %. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, Electrical Characteristics table, HiS-T640NJ column, "Module efficiency" row
[2] [1]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "Operating Temperature -40℃~+85℃" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026.
Where: "Operating Temperature" row
[2]
Other compliance claimsISO 9001, ISO 14001, ISO 45001
Printed as "· ISO 9001 : Quality management systems · ISO 14001 : Environmental management systems · ISO 45001 : Occupational health and safety management systems" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026. These are management-system standards listed beside the module certifications; no certificate scope or issuer is printed.
Where: Certification list
[2]
Temperature coefficient-0.29 %/°C
Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1; printed once for the whole series: "Temperature coefficient of Pmax %/℃ -0.290". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10), page 1, Electrical Characteristics table, "Temperature coefficient of Pmax" row
[2] [1]
Isc temperature coefficient0.043 %/°C
Printed as "Temperature coefficient of Isc %/℃ 0.043" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026.
Where: Electrical Characteristics, "Temperature coefficient of Isc %/℃" row
[2]
Voc temperature coefficient-0.25 %/°C
Printed as "Temperature coefficient of Voc %/℃ -0.250" in HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10), captured on September 25, 2026.
Where: Electrical Characteristics, "Temperature coefficient of Voc %/℃" row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
640 WEfficiency 22.9 %W / sq ft 21.3* (Calculated: 640 W ÷ (2,465 mm × 1,134 mm = 30.09 sq ft) = 21.3 W/sq ft)
Voltage (STC)
47.74 VNeeds confirmationVmp · maximum powerVoc · open circuit 57.77 VNeeds confirmationMax system 1,500 V
Current (STC)
13.41 ANeeds confirmationImp · maximum powerIsc · short circuit 14.06 ANeeds confirmation
Dimensions
D: 30 × W: 1,134 × L: 2,465 mm / D: 1.2 × W: 44.65 × L: 97.05 inWeight 34.7 kg / 76.5 lb
Warranty
12 yearsPower warranty 30 years

Evidence score

77/100100% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Every scored input has a recorded source for this product.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency22.9 %23.3 / 26.0

22.9 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiS-T640NJ column (column 2 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Module efficiency % 22.72 22.90 23.07"; the HiS-T640NJ figure is 22.90 %. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.

[2] [1]

Product warranty12 years8.4 / 21.0

12 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."

[2]

Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the maker. 870 solar panels share this value.

Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."

[2]

Power temperature coefficient-0.29 %/°C12.1 / 16.0

0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Read from the HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) hosted on eng.hd-hyundaies.co.kr, page 1; printed once for the whole series: "Temperature coefficient of Pmax %/℃ -0.290". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.

[2] [1]

First-year degradation1 %16.0 / 16.0

This is the lowest documented for a solar panel, printed by the maker. 420 solar panels share this value.

Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."

[2]

Weight / watt34.7 kg / 640 W1.1 / 5.0

0.05422 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module

34.7 kg / 640 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.

[2] [1]

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL 61215manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
HiS-T640NJ
Limitations
HD Hyundai Energy Solutions' own datasheet (HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10)) prints "UL 61215 / UL 61730 / IEC 61215 / IEC 61730 Certified" in its Certification list for the series that includes HiS-T640NJ. Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL 61730authority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
HIS-T640NJ
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as HD HYUNDAI ENERGY SOLUTIONS CO., LTD. "HiS-T640NJ": UL 61730, certifying entity not printed on the list, CEC listing date 2025-05-21. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: May 21, 2025
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[4]
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
HIS-T640NJ
Limitations
Model HIS-T640NJ listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under HD HYUNDAI ENERGY SOLUTIONS CO., LTD., as "HiS-T640NJ", CEC listing date 2025-05-21. The list prints "HiS-T640NJ"; the record's model "HIS-T640NJ" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: May 21, 2025
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[4]
IEC 61215manufacturer claimunknown[3]
Scope
equipment listing
Covered models
HIS-T640NJ
Limitations
Greentech Renewables prints "IEC 61215" in a certification, standards or compliance row on PDF page 1 of https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, a document this catalog already attaches to HIS-T640NJ; the value was located through a page that names HIS-T640NJ and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 19, 2026
Source
[3]
IEC 61730manufacturer claimunknown[3]
Scope
equipment listing
Covered models
HIS-T640NJ
Limitations
Greentech Renewables prints "IEC 61730" in a certification, standards or compliance row on PDF page 1 of https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, a document this catalog already attaches to HIS-T640NJ; the value was located through a page that names HIS-T640NJ and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 19, 2026
Source
[3]
UL 61730manufacturer claimunknown[3]
Scope
equipment listing
Covered models
HIS-T640NJ
Limitations
Greentech Renewables prints "UL 61730" in a certification, standards or compliance row on PDF page 1 of https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, a document this catalog already attaches to HIS-T640NJ; the value was located through a page that names HIS-T640NJ and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 19, 2026
Source
[3]

Warranty

FieldValueConditionsSource
Retention87.4 %
Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details." The guaranteed output at 30 years.
Where: HD Hyundai's Warranty Provisions
[2]
Warranty term12 years
Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."
Where: HD Hyundai's Warranty Provisions
[2]
Annual degradation0.4 %
Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details." Printed as percentage points per year after the first year.
Where: HD Hyundai's Warranty Provisions
[2]
Degradation year one1 %
Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."
Where: HD Hyundai's Warranty Provisions
[2]
Performance warranty30 years
Printed in the warranty provisions of HD Hyundai Energy Solutions' NJ Series HiS-T635/640/645NJ datasheet (26.09.10) as "12-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."
Where: HD Hyundai's Warranty Provisions
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Datasheets

  • HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10)Official · HD Hyundai Energy Solutions · Official datasheet · Web page
    Certificate & compliance claims (1)
    UL 61215Manufacturer claim · equipment listingClaimedListed when checked

    HD Hyundai Energy Solutions' own datasheet (HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10)) prints "UL 61215 / UL 61730 / IEC 61215 / IEC 61730 Certified" in its Certification list for the series that includes HiS-T640NJ. Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10)
    Source details
    Revision
    datasheet dated 26.09.10 in its file name
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Electrical Characteristics, Mechanical Characteristics, warranty provisions and Certification list

    Retrieved Sep 24, 2026

    HD Hyundai Energy Solutions' own NJ Series HiS-TxxxNJ datasheet, downloaded from the Technical Documents list of the module page on eng.hd-hyundaies.co.kr (the manufacturer's English site) and captured on September 25, 2026. It is the manufacturer's published specification (datasheet dated 26.09.10 in its file name); it does not establish independent test results, and its certification list is a manufacturer claim, not an issuer record.

    Archived copies

    Archived copy of a document published by HD Hyundai Energy Solutions. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupdatasheet dated 26.09.10 in its file name · 0.72 MB

    Archived copy, unaltered, kept as a record of what HD Hyundai Energy Solutions published. Original address: https://eng.hd-hyundaies.co.kr/api/common/fileDownload.do?id=5B1CC8428E337B58E0630100007F804B. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: f074a5fc7020e905d4a8a0eb2283a58775e0fd5079e76cdb098add4231b063bb

    Open
  • Other documents

  • Hyundai 640W 156 Half-Cell 1500V TOPCon Silver Bifacial Solar Panel, HIS-T640NJGreentech Renewables · Distributor product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Product listing

    Retrieved Sep 16, 2026

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • HIS-T640NJ · DocumentGreentech Renewables · Distributor document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Seller-linked document

    Retrieved Sep 16, 2026

    Linked by the seller for this model; manufacturer revision and applicability need confirmation.

    Open

Archived documents

HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10)

Archived copy of a document published by HD Hyundai Energy Solutions. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupdatasheet dated 26.09.10 in its file name · 0.72 MB

Archived copy, unaltered, kept as a record of what HD Hyundai Energy Solutions published. Original address: https://eng.hd-hyundaies.co.kr/api/common/fileDownload.do?id=5B1CC8428E337B58E0630100007F804B. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: f074a5fc7020e905d4a8a0eb2283a58775e0fd5079e76cdb098add4231b063bb

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HIS-T640NJ

Manufacturer SKU HIS-T640NJ

  1. Observed Oct 11, 2026

    UL 61730: claimed

    Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as HD HYUNDAI ENERGY SOLUTIONS CO., LTD. "HiS-T640NJ": UL 61730, certifying entity not printed on the list, CEC listing date 2025-05-21. A state equipment list entry, not the certification body's own record.

    [4]

  2. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model HIS-T640NJ listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under HD HYUNDAI ENERGY SOLUTIONS CO., LTD., as "HiS-T640NJ", CEC listing date 2025-05-21. The list prints "HiS-T640NJ"; the record's model "HIS-T640NJ" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.

    [4]

  3. Observed Sep 19, 2026

    UL 61730: claimed

    Product / system scope unresolved. Greentech Renewables prints "UL 61730" in a certification, standards or compliance row on PDF page 1 of https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, a document this catalog already attaches to HIS-T640NJ; the value was located through a page that names HIS-T640NJ and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    [3]

  4. Observed Sep 19, 2026

    IEC 61215: claimed

    Product / system scope unresolved. Greentech Renewables prints "IEC 61215" in a certification, standards or compliance row on PDF page 1 of https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, a document this catalog already attaches to HIS-T640NJ; the value was located through a page that names HIS-T640NJ and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    [3]

  5. Observed Sep 19, 2026

    IEC 61730: claimed

    Product / system scope unresolved. Greentech Renewables prints "IEC 61730" in a certification, standards or compliance row on PDF page 1 of https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800083_DS.pdf, a document this catalog already attaches to HIS-T640NJ; the value was located through a page that names HIS-T640NJ and no other model in this catalog. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    [3]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 100
basis: Unknown
missing: None listed
criteria:
key: efficiency
label: Module efficiency
value: 22.9
unit: Unknown
shown: 22.9 %
shown detail: Unknown
state: documented
points: 23.3
ceiling: 26
weight: 26
share: 89.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: warranty
label: Product warranty
value: 12
unit: Unknown
shown: 12 years
shown detail: Unknown
state: documented
points: 8.4
ceiling: 21
weight: 21
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: performanceWarranty
label: Power warranty
value: 30
unit: Unknown
shown: 30 years
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: powerTemperature
label: Power temperature coefficient
value: 0.29
unit: Unknown
shown: -0.29 %/°C
shown detail: Unknown
state: documented
points: 12.1
ceiling: 16
weight: 16
share: 75.9
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: degradation
label: First-year degradation
value: 1
unit: Unknown
shown: 1 %
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: weightPerWatt
label: Weight / watt
value: 0.0542
unit: Unknown
shown: 34.7 kg / 640 W
shown detail: Unknown
state: documented
points: 1.1
ceiling: 5
weight: 5
share: 22.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 34.7 kg / 640 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
display note: Unknown
Sources: [2] [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Hyundai 640W 156 Half-Cell 1500V TOPCon Silver Bifacial Solar Panel, HIS-T640NJ (Greentech Renewables · seller · observed Sep 16, 2026)
  2. HD Hyundai NJ Series HiS-T635/640/645NJ datasheet (26.09.10) (HD Hyundai Energy Solutions · manufacturer · datasheet dated 26.09.10 in its file name · observed Sep 24, 2026)
  3. HIS-T640NJ · Document (Greentech Renewables · seller · observed Sep 16, 2026)
  4. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)

Sign in to report an error on this page