Key specs

BrandHyundai Energy Solutions
ModelHIN-T435NF(BK)
Rated power435 W
Cell typeN-Type TOPCon
Module efficiency22.28 %
Open-circuit voltage38.6 V
Short-circuit current14.32 A
DimensionsW 1,134 × L 1,722 × D 30 mm / W 44.65 × L 67.8 × D 1.2 in converted
Weight24.5 kg / 54 lb converted
Product warranty25 years
Power warranty30 years

All specifications

Show all 29 specifications

Identity

BrandHyundai Energy Solutions · Website
ModelHIN-T435NF(BK)
MarketUnknown
Manufacturer SKUHIN-T435NF(BK) Provisional
SKU detail
locator: Part number
conditions: Seller-listed specification; not independently verified.
Sources: [1]
FieldValueConditionsSource
FrameAnodized aluminum alloy
Printed as "Frame Anodized aluminum alloy" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026.
Where: Mechanical Characteristics, "Frame" row
[2]
Current at max power13.56 A
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Current at Pmax (Impp) A 13.56 15.01 13.63 15.10 13.70 15.18"; the HiN-T435NF(BK) STC figure is 13.56 A. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Corrected on 25 September 2026: the catalog had published 15.01 A, cited to Greentech Renewables (cdn.myced.com). The earlier 15.01 A is the BNPI (bifacial nameplate irradiance, 1000 W/m² front plus 135 W/m² rear) sub-column of the HiN-T435NF(BK) column; both the CED copy of the earlier HD Hyundai revision (ZZ246800080_DS.pdf) and the current datasheet print 13.56 A in the STC sub-column. With 15.01 A the recorded Vmp x Imp was 481.8 W against the rated 435 W. Earlier note: "Read from Greentech Renewables's published document at https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800080_DS.pdf, from the column headed HIN-T435NF(BK). Printed value: "15.01". Standard test conditions as stated on that sheet. No value was taken from another model or from a name."
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, HiN-T435NF(BK) column, "Current at Pmax (Impp)" row
[2]
Short-circuit current14.32 A
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Short circuit current (Isc) A 14.32 15.87 14.39 15.94 14.46 16.02"; the HiN-T435NF(BK) STC figure is 14.32 A. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Corrected on 25 September 2026: the catalog had published 15.87 A, cited to Greentech Renewables (cdn.myced.com). The earlier 15.87 A is the BNPI sub-column of the HiN-T435NF(BK) column; the earlier revision (CED copy ZZ246800080_DS.pdf) and the current datasheet both print 14.32 A at STC. Earlier note: "Read from Greentech Renewables's published document at https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800080_DS.pdf, from the column headed HIN-T435NF(BK). Printed value: "15.87". Standard test conditions as stated on that sheet. No value was taken from another model or from a name."
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, HiN-T435NF(BK) column, "Short circuit current (Isc)" row
[2]
Voltage at max power32.1 V
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Voltage at Pmax (Vmpp) V 32.1 32.1 32.3 32.3 32.5 32.5"; the HiN-T435NF(BK) STC figure is 32.1 V. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (cdn.myced.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, HiN-T435NF(BK) column, "Voltage at Pmax (Vmpp)" row
[2] [3]
Open-circuit voltage38.6 V
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Open circuit voltage (Voc) V 38.6 38.6 38.8 38.8 39.0 39.0"; the HiN-T435NF(BK) STC figure is 38.6 V. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (cdn.myced.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, HiN-T435NF(BK) column, "Open circuit voltage (Voc)" row
[2] [3]
Noct44 °C / 111 °F converted
Printed as "Nominal Module Operation Temperature 44℃ ± 2℃" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026. The tolerance is ± 2℃.
Where: "Nominal Module Operation Temperature" row
[2]
Bifacialyes
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1; the Solar Cells row prints "N-Type TOPCon, 108 (6x18) monocrystalline 16BB half-cut bifacial cells", the Electrical Characteristics table prints "Bifaciality % 80±10" and a BNPI sub-column for every model. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, "Solar Cells" and "Bifaciality" rows
[2] [1]
Cell typeN-Type TOPCon
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Mechanical Characteristics; printed "Solar Cells N-Type TOPCon, 108 (6x18) monocrystalline 16BB half-cut bifacial cells". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Mechanical Characteristics, "Solar Cells" row
[2] [1]
Weight24.5 kg / 54 lb converted
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Mechanical Characteristics; printed "Weight 24.5 kg (54.01lbs)". Corrected on 25 September 2026: the catalog had published 22.6842 kg, cited to Greentech Renewables (greentechrenewables.com). The earlier 22.6842 kg is a conversion of the misprinted "50.01lbs" in the earlier HD Hyundai revision (CED copy ZZ246800080_DS.pdf printed "24.5 kg (50.01lbs)"); both revisions print 24.5 kg. Earlier note: "Seller-listed specification; not independently verified."
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Mechanical Characteristics, "Weight" row
[2]
Cell count108 cells
Printed as "Solar Cells N-Type TOPCon, 108 (6x18) monocrystalline 16BB half-cut bifacial cells" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026.
Where: Mechanical Characteristics, "Solar Cells" row
[2]
Front glass2.0mm(0.08in) semi-tempered solar glass with high transmittance and anti-reflective coating
Printed as "Front : 2.0mm(0.08in) semi-tempered solar glass with high transmittance and anti-reflective coating" in Hyundai Energy Solutions' HiN-TxxxNF(BK) 435-445W datasheet, captured on September 28, 2026.
Where: Datasheet page 1, Front row
[4]
Rear load pa5,400 Pa
Printed as "Maximum Test Load *See Installation Manual Front 5,400Pa *Rear 5,400Pa" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026. A test load; the installation manual sets the design loads by mounting method.
Where: "Maximum Test Load" row
[2]
Rear surface2.0mm(0.08in) semi-tempered solar glass
Printed as "Rear : 2.0mm(0.08in) semi-tempered solar glass" in Hyundai Energy Solutions' HiN-TxxxNF(BK) 435-445W datasheet, captured on September 28, 2026.
Where: Datasheet page 1, Rear row
[4]
DimensionsW 1,134 × L 1,722 × D 30 mm / W 44.65 × L 67.8 × D 1.2 in converted
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Mechanical Characteristics; printed "Dimensions 1,722mm (L) x 1,134mm (W) x 30mm (H)"; the record lists the 1722 mm figure as length, 1134 mm as width and the 30 mm frame height as depth. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Mechanical Characteristics, "Dimensions" row
[2] [1]
Front load pa5,400 Pa
Printed as "Maximum Test Load *See Installation Manual Front 5,400Pa *Rear 5,400Pa" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026. A test load; the installation manual sets the design loads by mounting method.
Where: "Maximum Test Load" row
[2]
Rated power435 W
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Nominal output (Pmax) W 435 482 440 488 445 493"; the HiN-T435NF(BK) STC figure is 435 W. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, HiN-T435NF(BK) column, "Nominal output (Pmax)" row
[2] [1]
Series fuse30 A ProvisionalSeller-listed specification; not independently verified.
Where: series-fuse-rating
[1]
Enclosure ratingIP68 (junction box)
Printed as "Junction Box 3-part, 3 bypass diodes, IP68 rated" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026.
Where: Mechanical Characteristics, "Junction Box" row
[2]
Max system voltage1,500 V
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1; printed once for the whole series: "Maximum System Voltage DC 1,500 V". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, "Maximum System Voltage" row
[2] [1]
Module efficiency22.28 %
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Module efficiency % 22.28 22.53 22.79"; the HiN-T435NF(BK) figure is 22.28 %. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Corrected on 25 September 2026: the catalog had published 24.68 %, cited to Greentech Renewables (greentechrenewables.com). The earlier 24.68% is the BNPI efficiency the earlier HD Hyundai revision printed beside the STC figure (CED copy ZZ246800080_DS.pdf: "22.28 24.68"); the current datasheet prints 22.28% only. Earlier note: "Seller-listed specification; not independently verified."
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, HiN-T435NF(BK) column, "Module efficiency" row
[2]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "Operating Temperature -40℃~+85℃" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026.
Where: "Operating Temperature" row
[2]
Other compliance claimsISO 9001:2015, ISO 14001:2015, ISO 45001:2018
Printed as "· ISO 9001:2015: Quality Management System · ISO 14001:2015: Environmental Management System · ISO 45001:2018: Occupational Health and Safety Management System" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026. These are management-system standards listed beside the module certifications; no certificate scope or issuer is printed.
Where: Certification list
[2]
Temperature coefficient-0.3 %/°C
Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1; printed once for the whole series: "Temperature coefficient of Pmax %/℃ -0.30". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.
Where: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), page 1, Electrical Characteristics table, "Temperature coefficient of Pmax" row
[2] [1]
Isc temperature coefficient0.046 %/°C
Printed as "Temperature coefficient of Isc %/℃ 0.046" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026.
Where: Electrical Characteristics, "Temperature coefficient of Isc %/℃" row
[2]
Voc temperature coefficient-0.25 %/°C
Printed as "Temperature coefficient of Voc %/℃ -0.25" in HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11), captured on September 25, 2026.
Where: Electrical Characteristics, "Temperature coefficient of Voc %/℃" row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
435 WEfficiency 22.28 %W / sq ft 20.7* (Calculated: 435 W ÷ (1,722 mm × 1,134 mm = 21.02 sq ft) = 20.7 W/sq ft)
Voltage (STC)
32.1 VVmp · maximum powerVoc · open circuit 38.6 VMax system 1,500 V
Current (STC)
13.56 AImp · maximum powerIsc · short circuit 14.32 A
Dimensions
D: 30 × W: 1,134 × L: 1,722 mm / D: 1.2 × W: 44.65 × L: 67.8 inWeight 24.5 kg / 54 lb
Warranty
25 yearsPower warranty 30 years

Evidence score

85/100100% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Every scored input has a recorded source for this product.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency22.28 %22.7 / 26.0

22.28 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1, Electrical Characteristics table, HiN-T435NF(BK) column (column 1 of 3); each model column has an STC sub-column followed by a BNPI (bifacial nameplate irradiance) sub-column, and the STC sub-column is used. Printed row: "Module efficiency % 22.28 22.53 22.79"; the HiN-T435NF(BK) figure is 22.28 %. STC: irradiance 1,000 W/m², cell temperature 25℃, AM=1.5. Corrected on 25 September 2026: the catalog had published 24.68 %, cited to Greentech Renewables (greentechrenewables.com). The earlier 24.68% is the BNPI efficiency the earlier HD Hyundai revision printed beside the STC figure (CED copy ZZ246800080_DS.pdf: "22.28 24.68"); the current datasheet prints 22.28% only. Earlier note: "Seller-listed specification; not independently verified."

[2]

Product warranty25 years17.5 / 21.0

25 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."

[2]

Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the maker. 870 solar panels share this value.

Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."

[2]

Power temperature coefficient-0.3 %/°C11.7 / 16.0

0.3 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Read from the HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) hosted on eng.hd-hyundaies.co.kr, page 1; printed once for the whole series: "Temperature coefficient of Pmax %/℃ -0.30". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Greentech Renewables (greentechrenewables.com), which stays listed as an additional source.

[2] [1]

First-year degradation1 %16.0 / 16.0

This is the lowest documented for a solar panel, printed by the maker. 420 solar panels share this value.

Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."

[2]

Weight / watt24.5 kg / 435 W1.1 / 5.0

0.05632 against 0.01227 kg per W, the lowest documented for a solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module

24.5 kg / 435 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.

[2] [1]

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 60068-2-68manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
HiN-T435NF(BK)
Limitations
HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
IEC 61701manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
HiN-T435NF(BK)
Limitations
HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
IEC 62716manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
HiN-T435NF(BK)
Limitations
HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
IEC 62804manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
HiN-T435NF(BK)
Limitations
HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL 61730manufacturer claimpresent at observation[2]
Scope
equipment listing
Covered models
HiN-T435NF(BK)
Limitations
HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2]
UL 61730authority listing reportedlisted as of snapshot[5]
Scope
equipment listing
Covered models
HIN-T435NF(BK)
Limitations
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as HD HYUNDAI ENERGY SOLUTIONS CO., LTD. "HiN-T435NF(BK)": UL 61730, certifying entity not printed on the list, CEC listing date 2025-01-02. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Jan 2, 2025
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[5]
CECauthority listing reportedlisted as of snapshot[5]
Scope
equipment listing
Covered models
HIN-T435NF(BK)
Limitations
Model HIN-T435NF(BK) listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under HD HYUNDAI ENERGY SOLUTIONS CO., LTD., as "HiN-T435NF(BK)", CEC listing date 2025-01-02. The list prints "HiN-T435NF(BK)"; the record's model "HIN-T435NF(BK)" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Jan 2, 2025
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[5]

Warranty

FieldValueConditionsSource
Retention87.4 %
Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details." The guaranteed output at 30 years.
Where: HD Hyundai's Warranty Provisions
[2]
Warranty term25 years
Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."
Where: HD Hyundai's Warranty Provisions
[2]
Annual degradation0.4 %
Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details." Printed as percentage points per year after the first year.
Where: HD Hyundai's Warranty Provisions
[2]
Degradation year one1 %
Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."
Where: HD Hyundai's Warranty Provisions
[2]
Performance warranty30 years
Printed in the warranty provisions of HD Hyundai Energy Solutions' NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) as "25-Year Product Warranty · Materials and workmanship", "30-Year Performance Warranty", "First year degradation: 1%" and "Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed" up to 30 years, captured on September 25, 2026. The datasheet adds "*Refer to HD HES standard warranty for details."
Where: HD Hyundai's Warranty Provisions
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Datasheets

  • HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)Official · HD Hyundai Energy Solutions · Official datasheet · Web page
    Certificate & compliance claims (5)
    UL 61730Manufacturer claim · equipment listingClaimedListed when checked

    HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)
    IEC 61701Manufacturer claim · equipment listingClaimedListed when checked

    HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)
    IEC 62716Manufacturer claim · equipment listingClaimedListed when checked

    HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)
    IEC 62804Manufacturer claim · equipment listingClaimedListed when checked

    HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)
    IEC 60068-2-68Manufacturer claim · equipment listingClaimedListed when checked

    HD Hyundai Energy Solutions' own datasheet (HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)) prints "UL 61730: Photovoltaic (PV) module safety qualification (CSA) · IEC 61701: Salt mist corrosion testing · IEC 62716: Ammonia corrosion testing · IEC 62804: Potential Induced Degradation (PID) testing · IEC 60068-2-68: Sand and dust testing for environmental durability" in its Certification list for the series that includes HiN-T435NF(BK). Recorded as the manufacturer prints it, captured on September 25, 2026; the datasheet names no certificate number for this standard and no issuer directory was read in this pass, so the claim is not issuer-verified.

    Manufacturer document

    Official datasheet: HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)
    Source details
    Revision
    datasheet dated 26.09.11 in its file name
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Electrical Characteristics, Mechanical Characteristics, warranty provisions and Certification list

    Retrieved Sep 24, 2026

    HD Hyundai Energy Solutions' own NF(BK) Series HiN-TxxxNF(BK) datasheet, downloaded from the Technical Documents list of the module page on eng.hd-hyundaies.co.kr (the manufacturer's English site) and captured on September 25, 2026. It is the manufacturer's published specification (datasheet dated 26.09.11 in its file name); it does not establish independent test results, and its certification list is a manufacturer claim, not an issuer record.

    Archived copies

    Archived copy of a document published by HD Hyundai Energy Solutions. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupdatasheet dated 26.09.11 in its file name · 0.64 MB

    Archived copy, unaltered, kept as a record of what HD Hyundai Energy Solutions published. Original address: https://eng.hd-hyundaies.co.kr/api/common/fileDownload.do?id=5B68774C1B5C22D0E0630100007F9973. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 20035f8b6b67a7519bbad6cda5f58014c270454717e61acbe2998d7f2d146039

    Open
  • Other documents

  • Hyundai Energy Solutions 435W 108 Half-Cell 1500V TOPCon Black Bifacial Solar Panel, HIN-T435NF(BK)Greentech Renewables · Distributor product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Product listing

    Retrieved Sep 16, 2026

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • ViewOfficial · cdn.myced.com · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Linked from the GreenTech Renewables product page with link text "View".

    Location: ZZ246800079_DS.pdf

    Retrieved Sep 18, 2026

    Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/hyundai-energy-solutions-440w-108-half-cell-1500v-topcon-black-bifacial-solar-panel-hin. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.

    SHA-256: 71f46d7b081375b09a9e1975e26dbc1f02670612c369fd52c994279f8c384d82

    Archived copies

    Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.59 MB

    Archived copy, unaltered, kept as a record of what cdn.myced.com published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800079_DS.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    None

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 71f46d7b081375b09a9e1975e26dbc1f02670612c369fd52c994279f8c384d82

    Open

Archived documents

View

Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.59 MB

Archived copy, unaltered, kept as a record of what cdn.myced.com published. Original address: https://cdn.myced.com/images/Products/ZZ0000/ZZ2468/00000/ZZ246800079_DS.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 71f46d7b081375b09a9e1975e26dbc1f02670612c369fd52c994279f8c384d82

HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11)

Archived copy of a document published by HD Hyundai Energy Solutions. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupdatasheet dated 26.09.11 in its file name · 0.64 MB

Archived copy, unaltered, kept as a record of what HD Hyundai Energy Solutions published. Original address: https://eng.hd-hyundaies.co.kr/api/common/fileDownload.do?id=5B68774C1B5C22D0E0630100007F9973. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 20035f8b6b67a7519bbad6cda5f58014c270454717e61acbe2998d7f2d146039

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HIN-T435NF(BK)

Manufacturer SKU HIN-T435NF(BK)

  1. Observed Oct 11, 2026

    UL 61730: claimed

    Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as HD HYUNDAI ENERGY SOLUTIONS CO., LTD. "HiN-T435NF(BK)": UL 61730, certifying entity not printed on the list, CEC listing date 2025-01-02. A state equipment list entry, not the certification body's own record.

    [5]

  2. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model HIN-T435NF(BK) listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under HD HYUNDAI ENERGY SOLUTIONS CO., LTD., as "HiN-T435NF(BK)", CEC listing date 2025-01-02. The list prints "HiN-T435NF(BK)"; the record's model "HIN-T435NF(BK)" differs only in letter case. This is an equipment listing, not UL certification or complete-system approval.

    [5]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 100
basis: Unknown
missing: None listed
criteria:
key: efficiency
label: Module efficiency
value: 22.28
unit: Unknown
shown: 22.28 %
shown detail: Unknown
state: documented
points: 22.7
ceiling: 26
weight: 26
share: 87.4
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: warranty
label: Product warranty
value: 25
unit: Unknown
shown: 25 years
shown detail: Unknown
state: documented
points: 17.5
ceiling: 21
weight: 21
share: 83.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: performanceWarranty
label: Power warranty
value: 30
unit: Unknown
shown: 30 years
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: powerTemperature
label: Power temperature coefficient
value: 0.3
unit: Unknown
shown: -0.3 %/°C
shown detail: Unknown
state: documented
points: 11.7
ceiling: 16
weight: 16
share: 73.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: degradation
label: First-year degradation
value: 1
unit: Unknown
shown: 1 %
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: weightPerWatt
label: Weight / watt
value: 0.0563
unit: Unknown
shown: 24.5 kg / 435 W
shown detail: Unknown
state: documented
points: 1.1
ceiling: 5
weight: 5
share: 21.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: 24.5 kg / 435 W. Lighter modules per watt carry less roof load. Panel format is not documented, so this is compared with every panel.
display note: Unknown
Sources: [2] [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Hyundai Energy Solutions 435W 108 Half-Cell 1500V TOPCon Black Bifacial Solar Panel, HIN-T435NF(BK) (Greentech Renewables · seller · observed Sep 16, 2026)
  2. HD Hyundai NF(BK) Series HiN-T435/440/445NF(BK) datasheet (26.09.11) (HD Hyundai Energy Solutions · manufacturer · datasheet dated 26.09.11 in its file name · observed Sep 24, 2026)
  3. HIN-T435NF(BK) · Document (Greentech Renewables · seller · observed Sep 16, 2026)
  4. View (cdn.myced.com · manufacturer · observed Sep 18, 2026)
  5. CEC PV Module List, official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price