Printed as "Frame 1.18 inch (30 mm) black aluminium frame" in Axitec's DB_108zlg_blackprem XXL HC_MiA_US_ETL 400-420 datasheet (MH/108VB), captured on September 28, 2026.
Read from the AC-405MH/108VB row of the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), Electrical data at standard test conditions (irradiance 1000 W/m², AM 1.5, cell temperature 25°C). The header prints "Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency" and the model row prints "AC-405MH/108VB 405 Wp 31.21 V 12.98 A 13.87 A 37.23 V 20.74 %". Captured on September 25, 2026.
Where: Electrical data (STC), AC-405MH/108VB row, Impp
Read from the AC-405MH/108VB row of the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), Electrical data at standard test conditions (irradiance 1000 W/m², AM 1.5, cell temperature 25°C). The header prints "Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency" and the model row prints "AC-405MH/108VB 405 Wp 31.21 V 12.98 A 13.87 A 37.23 V 20.74 %". Captured on September 25, 2026.
Where: Electrical data (STC), AC-405MH/108VB row, Isc
Read from the AC-405MH/108VB row of the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), Electrical data at standard test conditions (irradiance 1000 W/m², AM 1.5, cell temperature 25°C). The header prints "Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency" and the model row prints "AC-405MH/108VB 405 Wp 31.21 V 12.98 A 13.87 A 37.23 V 20.74 %". Captured on September 25, 2026.
Where: Electrical data (STC), AC-405MH/108VB row, Umpp
Read from the AC-405MH/108VB row of the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), Electrical data at standard test conditions (irradiance 1000 W/m², AM 1.5, cell temperature 25°C). The header prints "Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency" and the model row prints "AC-405MH/108VB 405 Wp 31.21 V 12.98 A 13.87 A 37.23 V 20.74 %". Captured on September 25, 2026.
Where: Electrical data (STC), AC-405MH/108VB row, Uoc
Printed as "Cells 108 monocrystalline high efficiency cells" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026.
Printed as "Weight 47.40 lbs (21.5 kg) with frame" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026. One value for the whole family.
0.13 inch (3.2 mm) hardened, low-reflection white glass
Printed as "Frontside 0.13 inch (3.2 mm) hardened, low-reflection white glass" in Axitec's DB_108zlg_blackprem XXL HC_MiA_US_ETL 400-420 datasheet (MH/108VB), captured on September 28, 2026.
W 1,134 × L 1,722 × T 30 mm / W 44.65 × L 67.8 × T 1.2 in converted
Printed as "L x W x H 67.80 x 44.65 x 1.18 inch(1722 x 1134 x 30 mm)" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026. Length x width x frame height; one value for the whole family.
Printed as "System voltage 1500 VDC (UL) 1500 VDC (IEC)" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026.
Read from the AC-405MH/108VB row of the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), Electrical data at standard test conditions (irradiance 1000 W/m², AM 1.5, cell temperature 25°C). The header prints "Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency" and the model row prints "AC-405MH/108VB 405 Wp 31.21 V 12.98 A 13.87 A 37.23 V 20.74 %". Captured on September 25, 2026.
Where: Electrical data (STC), AC-405MH/108VB row, Module conversion efficiency
Printed as "Output Pmpp -0.35 %/K" in Axitec reference document, Datasheet, Temperature coefficients table, "Output Pmpp" row. Revised on 1 October 2026: The datasheet prints -0.35 %/K for this module family; a change of one kelvin equals a change of one degree Celsius, so the figure is the same per °C.
Where: Datasheet, Temperature coefficients table, "Output Pmpp" row
Sources
Converted: -0.35 %/K x 1 (1 K temperature difference = 1 °C)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the AC-405MH/108VB row of the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), Electrical data at standard test conditions (irradiance 1000 W/m², AM 1.5, cell temperature 25°C). The header prints "Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency" and the model row prints "AC-405MH/108VB 405 Wp 31.21 V 12.98 A 13.87 A 37.23 V 20.74 %". Captured on September 25, 2026.
Printed as "25 years Manufacturer‘s warranty" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026. Headline figure only; the datasheet does not print the warranty terms, exclusions or claim process.
Printed as "25 years Performance guarantee" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026. Headline figure only; the yearly output steps appear only as chart labels.
Power temperature coefficient-0.35 %/°C10.1 / 16.0
0.35 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Output Pmpp -0.35 %/K" in Axitec reference document, Datasheet, Temperature coefficients table, "Output Pmpp" row. Revised on 1 October 2026: The datasheet prints -0.35 %/K for this module family; a change of one kelvin equals a change of one degree Celsius, so the figure is the same per °C.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
ETL STD No.1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
AC-405MH/108VB
Limitations
Axitec's own Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A) prints "Conforms to ETL STD No.1703" in its certification mark block for the family that includes AC-405MH/108VB. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
IEC 61730manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
AC-405MH/108VB
Limitations
Axitec's own Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A) prints "Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730)" in its Limit values (a fire class rating) for the family that includes AC-405MH/108VB. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
AC-405MH/108VB
Limitations
Axitec's own Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A) prints "Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730)" in its Limit values (a fire performance rating) for the family that includes AC-405MH/108VB. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
ULC/ORD Std. C1703manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
AC-405MH/108VB
Limitations
Axitec's own Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A) prints "Certified to ULC/ORD Std. C1703" in its certification mark block for the family that includes AC-405MH/108VB. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Printed as "25 years Manufacturer‘s warranty" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026. Headline figure only; the datasheet does not print the warranty terms, exclusions or claim process.
Printed as "25 years Performance guarantee" in the Axitec AXIblackpremium XXL HC 400 - 420 Wp datasheet (108MHEN250521A), captured on September 25, 2026. Headline figure only; the yearly output steps appear only as chart labels.
Archived copy of a document published by Axitec. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Axitec reference document
Archived copy of a document published by Axitec. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].