Converted: -0.31 %/K x 1 (1 K temperature difference = 1 °C)
Printed as "Output Pmpp -0.31 %/K" in AXIworldblackbiperfect GXXL 430 - 450 Wp, High performance bifacial solar module, 108 halfcell, glass/glass, N-Type TOPCon, Datasheet, Temperature coefficients table, "Output Pmpp" row. Revised on 1 October 2026: The datasheet prints -0.31 %/K for this module family; a change of one kelvin equals a change of one degree Celsius, so the figure is the same per °C.
Converted: -0.31 %/K x 1 (1 K temperature difference = 1 °C)
Printed as "Output Pmpp -0.31 %/K" in AXIworldblackbiperfect GXXL 430 - 450 Wp, High performance bifacial solar module, 108 halfcell, glass/glass, N-Type TOPCon, Datasheet, Temperature coefficients table, "Output Pmpp" row. Revised on 1 October 2026: The datasheet prints -0.31 %/K for this module family; a change of one kelvin equals a change of one degree Celsius, so the figure is the same per °C.
Printed as "108 halfcell, glass/glass, N-Type TOPCon" in AXIworldblackbiperfect GXXL 430 - 450 Wp, High performance bifacial solar module, 108 halfcell, glass/glass, N-Type TOPCon, Datasheet, page 1 heading and Design section (2.0 mm glass front and back, 30 mm aluminium frame). Revised on 1 October 2026: The datasheet prints glass/glass construction with an aluminium frame, which is the rigid panel format.
Published claims and calculations, not independent test results.
Documents
2 on file
PDF
AXIworldblackbiperfect GXXL 430 - 450 Wp: High performance bifacial solar module, 108 halfcell, glass/glass, N-Type TOPConOfficialAXITEC, LLCOfficial datasheet
Certificate & compliance claims (5)
UL 1703Manufacturer claim · equipment listingClaimedStatus unconfirmed
Page 1, certification mark block (file no. 5026791). Printed wording: Conforms to UL STD No.1703. Manufacturer document claim; the issuer record was not checked.
UL 1703 (fire performance)Manufacturer claim · equipment listingClaimedStatus unconfirmed
Page 2, Limit values. Printed wording: Module Fire Performance TYPE 29 (UL 1703) or CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
Page 2, Limit values, Module Fire Performance row. Printed wording: CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
Axitec 440W Bifacial: Current Connected exact listingCurrent ConnectedDistributor product page
Source details
Revision
Not stated
Revision date
Not stated
Exact raw HTML capture and hash are retained in the manifest research archive; the product source archive UI is PDF-only.
Location: JSON-LD product identity and visible product description
Retrieved
Seller listing. Technical values cited only as seller statements unless another source is named; seller SKU does not establish a manufacturer hardware revision.
Archived copy of a document published by cdn.currentconnected.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Every scored input has a recorded source for this product.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Power temperature coefficient-0.31 %/°C11.4 / 16.0
0.31 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Output Pmpp -0.31 %/K" in AXIworldblackbiperfect GXXL 430 - 450 Wp, High performance bifacial solar module, 108 halfcell, glass/glass, N-Type TOPCon, Datasheet, Temperature coefficients table, "Output Pmpp" row. Revised on 1 October 2026: The datasheet prints -0.31 %/K for this module family; a change of one kelvin equals a change of one degree Celsius, so the figure is the same per °C.
UL 1703Product / system scope unresolvedClaimedStatus unconfirmed
Page 1, certification mark block (file no. 5026791). Printed wording: Conforms to UL STD No.1703. Manufacturer document claim; the issuer record was not checked.
UL 1703 (fire performance)Product / system scope unresolvedClaimedStatus unconfirmed
Page 2, Limit values. Printed wording: Module Fire Performance TYPE 29 (UL 1703) or CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
IEC 61730Product / system scope unresolvedClaimedStatus unconfirmed
Page 2, Limit values, Module Fire Performance row. Printed wording: CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
UL 61730Product / system scope unresolvedClaimedListed when checked
Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as AXITEC "AC-440TGB/108BB": UL 61730, certifying entity not printed on the list, CEC listing date 2025-09-11. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
CECProduct / system scope unresolvedClaimedListed when checked
Model AC-440TGB/108BB listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under AXITEC, as "AC-440TGB/108BB", CEC listing date 2025-09-11. This is an equipment listing, not UL certification or complete-system approval.
UL 1703Manufacturer claim · equipment listingClaimedStatus unconfirmed
Page 1, certification mark block (file no. 5026791). Printed wording: Conforms to UL STD No.1703. Manufacturer document claim; the issuer record was not checked.
UL 1703 (fire performance)Manufacturer claim · equipment listingClaimedStatus unconfirmed
Page 2, Limit values. Printed wording: Module Fire Performance TYPE 29 (UL 1703) or CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
Page 2, Limit values, Module Fire Performance row. Printed wording: CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
AC-440TGB/108BB
Manufacturer SKU AC-440TGB/108BB · US market
Observed
UL 61730: claimed
Product / system scope unresolved. Listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) as AXITEC "AC-440TGB/108BB": UL 61730, certifying entity not printed on the list, CEC listing date 2025-09-11. The maker's documents claim UL 1703; the CEC list records UL 61730 for this model. Both are shown; neither replaces the other. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model AC-440TGB/108BB listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under AXITEC, as "AC-440TGB/108BB", CEC listing date 2025-09-11. This is an equipment listing, not UL certification or complete-system approval.
Product / system scope unresolved. Page 1, certification mark block (file no. 5026791). Printed wording: Conforms to UL STD No.1703. Manufacturer document claim; the issuer record was not checked.
Product / system scope unresolved. Page 1, certification mark block. Printed wording: Certified to ULC/ORD Std. C1703. Manufacturer document claim; the issuer record was not checked.
Product / system scope unresolved. Page 2, Limit values. Printed wording: Module Fire Performance TYPE 29 (UL 1703) or CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
Product / system scope unresolved. Page 2, Limit values, Module Fire Performance row. Printed wording: CLASS C (IEC 61730). Manufacturer document claim; the issuer record was not checked.
Product / system scope unresolved. Page 2, Limit values. Printed wording: Protection class C (UL790) / II. Manufacturer document claim; the issuer record was not checked.