locator: Victron Energy price list 2026-Q3, page 4, row "Quattro-II 12/3000/120-50/50 2x120V" QUA122305130
conditions: Victron Energy's 2026-Q3 price list prints article number QUA122305130 on the row for "Quattro-II 12/3000/120-50/50 2x120V" (page 4), this record's product.
This product is a safety class I device (supplied with a ground terminal for safety purposes).; An additional grounding point is located on the product's exterior.
Printed as "This product is a safety class I device" and "An additional grounding point is located on the product's exterior" in the Victron Energy Quattro-II 2x120V manual (PDF page 3). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 3, 1. Important safety instructions, Installation
Victron documents print 32.8 kg and 23.8 kg. The Quattro-II 2x120V datasheet and Victron product data print "32.8 kg (52 lb)" for the 12/3000/120-50/50; the Quattro-II 2x120V manual (Rev 04 - 11/2026) prints "23.8 kg ( 52 lb)". Both print 52 lb; neither explains the kilogram difference.
Printed as "23.8 kg" in the 12/3000/120-50 column of the Quattro-II 2x120V manual, captured on September 26, 2026. Revised on 26 September 2026: The manufacturer manual prints a different value; the owner decided the manual value is shown first and the recorded value stays as a cited alternative.
Printed as "Peak power 5500 W" in the Victron Quattro-II 3kVA 2x120V datasheet, captured on September 25, 2026; the 12/3000/120-50 2x120V column reads "5500 W" (one value printed for both models).
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy Quattro-II 2x120V manual (PDF page 26). Output voltage in inverter mode, common to both models; the enclosure rows print a "120/240VAC-connection". The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 26, 7. Technical specifications, Inverter, "Output in inverter mode" row
Printed as "CHARGER AC Input Split phase: 180-280VAC" and "Maximum battery charge current (4) 120A 70A" in the Victron Energy Quattro-II 2x120V manual (PDF page 26). Charger section, AC input. The columns are 12/3000/120-50 and 24/3000/70-50 in that order. The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Printed as "Output when in inverter mode Output voltage: 120 Vac ± 2 %" in the Victron Quattro-II 3kVA 2x120V datasheet, captured on September 25, 2026; the 12/3000/120-50 2x120V column reads "120 Vac ± 2 %".
Printed as "Quattro-II 2x120V - 3k models AC-in 1 AC-in 2 AC-Out-1 AC-Out-2" and "Recommend fuse or circuit breaker 50 A 50 A 75 A 50 A" and "fuse or magnetic circuit breaker rated at 50A or less" in the Victron Energy Quattro-II 2x120V manual (PDF page 16). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 16, 4.4 Connection of the AC cabling, "Quattro-II 2x120V - 3k models" table, "Recommend fuse or circuit breaker" row
Victron documents print IP22 and IP21. The Victron datasheet and product data print "Protection category IP22"; the Quattro-II 2x120V manual (captured on September 26, 2026) prints "Protection category IP21". Neither document explains the difference.
Printed as "Protection category IP21" for every model in the Quattro-II 2x120V manual, captured on September 26, 2026. Revised on 26 September 2026: The manufacturer manual prints a different value; the owner decided the manual value is shown first and the recorded value stays as a cited alternative.
Printed as "The ground conductor should be at least 4mm²" in the Victron Energy Quattro-II 2x120V manual (PDF page 3). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 3, 1. Important safety instructions, Installation
AC-Out-1: 75 A; AC-Out-2: 50 A (fuse or circuit breaker)
Printed as "Quattro-II 2x120V - 3k models AC-in 1 AC-in 2 AC-Out-1 AC-Out-2" and "Recommend fuse or circuit breaker 50 A 50 A 75 A 50 A" in the Victron Energy Quattro-II 2x120V manual (PDF page 16). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 16, 4.4 Connection of the AC cabling, "Quattro-II 2x120V - 3k models" table, "Recommend fuse or circuit breaker" row
2x AWG 1/0 (cables 0 to 5 m); 2x AWG 2/0 (5 to 10 m)
Printed as "12/3000/120 400 - 1200Ah 400A 2x AWG 1/0 2x AWG 2/0" (cross-section per positive and negative terminal) in the Quattro-II 2x120V manual, captured on September 26, 2026.
Programmable relay can be set for genset start/stop
Printed as a programmable relay "which can be set for general alarm, DC under voltage or genset start/stop function" in the Quattro-II 2x120V manual, captured on September 26, 2026.
Printed as "Model Battery capacity DC fuse" and "12/3000/120 400 - 1200Ah 400A" in the Victron Energy Quattro-II 2x120V manual (PDF page 15). The row reads battery capacity, then DC fuse. The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 15, 4.3 Connection of battery cables, table, "DC fuse" column, 12/3000/120 row
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy Quattro-II 2x120V manual (PDF page 26). Common to both models. The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 26, 7. Technical specifications, Inverter, "Output in inverter mode" row
VE.Bus communication port: for parallel and three-phase operation, remote monitoring and system integration; General purpose communication port: Yes, 2x
Printed as "VE.Bus communication port For parallel and three-phase operation" and "General purpose communication port (6) Yes, 2x" in the Victron Energy Quattro-II 2x120V manual (PDF page 26). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 26, 7. Technical specifications, General
Printed as "INVERTER DC Input voltage range 9.5 – 17V 19 - 33V" in the Victron Energy Quattro-II 2x120V manual (PDF page 26). The columns are 12/3000/120-50 and 24/3000/70-50 in that order. The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 26, 7. Technical specifications, Inverter, "DC Input voltage range" row, 12/3000/120-50 column
Printed as "Cont. output power at 25 °C 2400 W" in the Victron Quattro-II 3kVA 2x120V datasheet, captured on September 25, 2026; the 12/3000/120-50 2x120V column reads "2400 W" (one value printed for both models). Recorded in kW as a change of unit of that figure.
Where: Victron Quattro-II 3kVA 2x120V datasheet, specification table, "Cont. output power at 25 °C" row, 12/3000/120-50 2x120V column
Printed as "The inverter/charger is suitable for wall mounting" in the Victron Energy Quattro-II 2x120V manual (PDF page 13). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
DC fuse 400 A; AC-in-1 and AC-in-2 50 A, AC-out-1 75 A, AC-out-2 50 A fuse or circuit breaker
Printed as the "DC fuse" column of the battery table and "Recommend fuse or circuit breaker" row of the AC table in the Quattro-II 2x120V manual, captured on September 26, 2026.
A ground relay (relay H) automatically connects the Neutral output to the chassis if no external AC supply is available; if an external AC supply is provided, ground relay H opens before the input safety relay closes.
Printed as "automatically connects the Neutral output to the chassis if no external AC supply is available" and "the ground relay H will open before the input safety relay closes" in the Victron Energy Quattro-II 2x120V manual (PDF page 16). The manual names "QUA122305130 Quattro-II 12/3000/120-50/50 2x120V" and "QUA242305130 Quattro-II 24/3000/70-50/50 2x120V" in its dimension drawings (PDF page 33).
Where: PDF page 16, 4.4 Connection of the AC cabling
Lowest first. Each price is the date we last read it; it may have changed. Stock isn't shown.
Store
Price
Read
Details
Source
Current Connected
$1,234.20
Nov 15, 2026
List price of the single listing with seller SKU QUA122305130, as the schema.org Product record on the Current Connected product page printed it on 20 September 2026. One unit as listed; shipping, sales tax, permitting and installation are extra. · Store SKU QUA122305130Price readings (53)
31.03 L* (Calculated from published dimensions)W: 319 × H: 579 × D: 168 mm / W: 12.6 × H: 22.8 × D: 6.61 inWeight23.8 kg / 52.5 lb
Evidence score
11/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA122305130. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA122305130. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
4 on file
Manuals
PDF
Quattro-II 2x120V manualOfficial · Victron Energy · Official installation manual · PDFSource details
Revision
Rev 04 - 11/2026
Revision date
Not stated
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: 4.3 Connection of battery cables; 4.4 Connection of the AC cabling; 7 Technical specifications
Retrieved Sep 25, 2026
Victron Energy's own installation and user manual for the Quattro-II 2x120V family, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs QUA122305130, QUA242305130. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Rows by article number
Retrieved Sep 22, 2026
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Victron Energy reference document
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Quattro-II 12/3000/120-50/50 2x120V
Manufacturer SKU QUA122305130
Observed Sep 18, 2026
EN-IEC 60335-1: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA122305130. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA122305130. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.