locator: Victron Energy price list 2026-Q3, page 4, row "Quattro 48/3000/35-50/50 120V" QUA483021100
conditions: Victron Energy's 2026-Q3 price list prints article number QUA483021100 on the row for "Quattro 48/3000/35-50/50 120V" (page 4), this record's product.
Printed as "Peak power 6000 W 10000 W 20000 W" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/3000/35-50/50 120V column reads "6000 W" (the table prints one value per power class: 3000, 5000 and 10000 VA).
Printed as "Output when in inverter mode Output voltage: 120 VAC ± 2 %" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/3000/35-50/50 120V column reads "120 VAC ± 2 %".
A fuse or magnetic circuit breaker rated at 50A or less
Printed as "protected by a fuse or magnetic circuit breaker rated at 50A or less" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 12). The same requirement is printed for AC-in-2.
Where: PDF page 12, 4.3 Connecting AC cables, AC-in-1
Printed as "This happens so fast (less than 20 milliseconds) that computers and other ele ctronic equipment will continue to operate without disruption."
Where: Quattro 3kVA - 10kVA 120V datasheet, Two AC Outputs section
The maximum rating of the fuse or circuit breaker is 63A
Printed as "The maximum rating of the fuse or circuit breaker is 63A" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 12). Printed for AC-out-1. For AC-out-2 the page says an earth leakage circuit breaker and fuse rated at max. 25A must be connected in series.
Where: PDF page 12, 4.3 Connecting AC cables, AC-out-1
Printed as the "Recommended cross-section (mm2) per + and - connection terminal" row, 48/3000/35 column, in the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
Programmable relay which can be set for general alarm, DC undervoltage or genset start/stop function
Printed as "Programmable relay which can be set for general alarm" and "DC undervoltage or genset start/stop function" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 25). Section 4.3 (PDF page 12) adds that generally a generator will be connected to AC-in-1.
Where: PDF page 25, 8. Technical Specifications, footnote 5
Printed as "Recommended battery capacity (Ah) 100–400 Recommended DC fuse 125A" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 11). Section 4.1 says the Quattro has no internal DC fuse and the DC fuse should be installed outside the Quattro.
Where: PDF page 11, 4.2 Connecting the battery cables, table
Printed as "A maximum of six units connected in parallel" (identical devices with the same power ratings) in the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
2x RJ45 connector for remote panel and/or parallel and 3-phase operation
Printed as "B 2x RJ45 connector for remote panel and/or parallel and 3-phase operation" and "I Alarm contact: (left to right) NC, NO, COM" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 28).
Where: PDF page 28, Appendix A Connection overview, items B and I
Printed as "Cont. output power at 25 °C / 77 °F 2400 W 4000 W 8000 W" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/3000/35-50/50 120V column reads "2400 W" (the table prints one value per power class: 3000, 5000 and 10000 VA). Recorded in kW as a change of unit of that figure.
Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Cont. output power at 25 °C / 77 °F" row, 48/3000/35-50/50 120V column
The device can be fitted either horizontally or vertically. For optimal cooling, vertical fitting is preferred.
Printed as "The device can be fitted either horizontally or vertically" and "For optimal cooling, vertical fitting is preferred" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 11).
DC fuse 125 A; AC-in-1 fuse or magnetic circuit breaker rated at 50 A or less
Printed as "Recommended DC fuse" in the battery table and in the AC connection instructions of the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
The Quattro is provided with a ground relay that automatically connects the N output to the casing if no external AC supply is available
Printed as "The Quattro is provided with a ground relay (see appendix)" and "automatically connects the N output to the casing if no external AC supply is available" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 12). The page adds that the ground relay opens before the input safety relay closes when an external AC supply is provided.
Price as of Nov 16, 2026, 11:25 AM PST, may change
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Checked Nov 16, 2026
More info
Price from the Amazon Creators API for the New-condition featured offer. Price checked Nov 16, 2026, 11:25 AM PST.
Amazon$1,330.70 Paid link. As an Amazon Associate we earn from qualifying purchases.
List price of the exact variant with stock keeping unit QUA483021100 as published in the ShopSolar Shopify product feed on 20 September 2026. The same feed prints a compare-at price of 2199.00 US dollars for this variant. One unit as listed; shipping, sales tax, permitting and installation are extra. · Store SKU QUA483021100Price readings (34)
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Price history
Prices we read at ShopSolar and Signature Solar · 42 readings from to
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: 4.2 Battery connection; 4.3 AC connection; parallel connection
Retrieved Sep 25, 2026
Victron Energy's own manual for the Quattro 48/3000/35-50/50 120V, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs QUA125021100, QUA245023110, QUA483021100, QUA485021100, QUA483100100, QUA483100102, QUA482501102. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Modbus-TCP register listOfficial · Victron Energy · Official product page · Web pageSource details
Revision
Not stated
Revision date
Not stated
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Rows by article number
Retrieved Sep 22, 2026
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
WEB
Marine Integration GuideOfficial · Victron Energy · Official product page · Web pageSource details
Revision
Not stated
Revision date
Not stated
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)
Order: products a manufacturer names first, then by Evidence score at default weights.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Quattro 48/3000/35-50/50 120V
Manufacturer SKU QUA483021100
Observed Sep 18, 2026
EN-IEC 60335-1: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.