Charged ReviewsSaved 0Compare 0Login

Victron Energy Quattro 48/3000/35-50/50 120V

Key specs

BrandVictron Energy
ModelQuattro 48/3000/35-50/50 120V
Continuous output2,400 W
Apparent power3,000 VA
Surge output6,000 W
Battery operating voltage[38, 66] VDC V
AC configuration120 VAC
Efficiency94 %
Weight19 kg / 42 lb converted
Product warranty5 years
Victron Energy Quattro 48/3000/35-50/50 120Vread Nov 15, 2026

All specifications

Show all 38 specifications

Identity

BrandVictron Energy · Website
ModelQuattro 48/3000/35-50/50 120V
MarketUnknown
Manufacturer SKUQUA483021100
SKU detail
locator: Victron Energy price list 2026-Q3, page 4, row "Quattro 48/3000/35-50/50 120V" QUA483021100
conditions: Victron Energy's 2026-Q3 price list prints article number QUA483021100 on the row for "Quattro 48/3000/35-50/50 120V" (page 4), this record's product.
Sources: [1]
FieldValueConditionsSource
Weight19 kg / 42 lb converted
Published value for this exact SKU: "19 kg".
Where: Victron public API technical data: weight
[2]
Peak output6000 W
Printed as "Peak power 6000 W 10000 W 20000 W" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/3000/35-50/50 120V column reads "6000 W" (the table prints one value per power class: 3000, 5000 and 10000 VA).
Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Peak power" row, 48/3000/35-50/50 120V column
[3]
Max charge35 A
Printed as "Charge current house battery (A) (4) 35" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 25). Footnote 4: at 25°C ambient.
Where: PDF page 25, 8. Technical Specifications, Charger, Charge current house battery (A) row
[4]
ClearancesThe device should be surrounded by a free space of at least 10 cm for cooling purposes.
Printed as "The device should be surrounded by a free space of at least 10 cm" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 11).
Where: PDF page 11, 4.1 Location
[4]
DimensionsW 258 × H 362 × D 218 mm / W 10.2 × H 14.3 × D 8.58 in converted
Published enclosure dimensions for this exact SKU: height 362 mm, width 258 mm, depth 218 mm. Mounting clearances are separate.
Where: Victron public API technical data: height, width, depth
[2]
CommunicationsVE.Bus
Published value for this exact SKU: "VE.Bus".
Where: Victron public API technical data: communicationPort
[2]
Efficiency94 %
Published value for this exact SKU: "94 %".
Where: Victron public API technical data: maxEfficiency
[2]
AC frequency60 Hz
Published value for this exact SKU: "60 Hz".
Where: Victron public API technical data: aCOutputFrequency
[2]
Max AC charge35 A
Printed as "Charge current house battery (A) (4) 35" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 25). Footnote 4: at 25°C ambient.
Where: PDF page 25, 8. Technical Specifications, Charger, Charge current house battery (A) row
[4]
AC configuration120 VAC
Printed as "Output when in inverter mode Output voltage: 120 VAC ± 2 %" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/3000/35-50/50 120V column reads "120 VAC ± 2 %".
Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Output voltage" row, 48/3000/35-50/50 120V column
[3]
AC input breakerA fuse or magnetic circuit breaker rated at 50A or less
Printed as "protected by a fuse or magnetic circuit breaker rated at 50A or less" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 12). The same requirement is printed for AC-in-2.
Where: PDF page 12, 4.3 Connecting AC cables, AC-in-1
[4]
Enclosure ratingIP21
Published value for this exact SKU: "IP21".
Where: Victron public API technical data: protectionCategory
[2]
Transfer time20 ms
Printed as "This happens so fast (less than 20 milliseconds) that computers and other ele ctronic equipment will continue to operate without disruption."
Where: Quattro 3kVA - 10kVA 120V datasheet, Two AC Outputs section
[3]
AC output breakerThe maximum rating of the fuse or circuit breaker is 63A
Printed as "The maximum rating of the fuse or circuit breaker is 63A" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 12). Printed for AC-out-1. For AC-out-2 the page says an earth leakage circuit breaker and fuse rated at max. 25A must be connected in series.
Where: PDF page 12, 4.3 Connecting AC cables, AC-out-1
[4]
Apparent power3,000 VA
Published value for this exact SKU: "3,000 VA".
Where: Victron public API technical data: contPowerVA25
[2]
Battery wire size35 mm² (cables 0 to 5 m); 2x 35 mm² (5 to 10 m)
Printed as the "Recommended cross-section (mm2) per + and - connection terminal" row, 48/3000/35 column, in the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
Where: Battery connection table, 48/3000/35 column
[5]
Generator supportProgrammable relay which can be set for general alarm, DC undervoltage or genset start/stop function
Printed as "Programmable relay which can be set for general alarm" and "DC undervoltage or genset start/stop function" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 25). Section 4.3 (PDF page 12) adds that generally a generator will be connected to AC-in-1.
Where: PDF page 25, 8. Technical Specifications, footnote 5
[4]
Nominal voltage48 V
Published value for this exact SKU: "48 V".
Where: Victron public API technical data: batteryVoltageNominal
[2]
Surge AC output6,000 W
Published value for this exact SKU: "6,000 W".
Where: Victron public API technical data: peakPowerRating
[2]
Battery protectionRecommended DC fuse 125A
Printed as "Recommended battery capacity (Ah) 100–400 Recommended DC fuse 125A" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 11). Section 4.1 says the Quattro has no internal DC fuse and the DC fuse should be installed outside the Quattro.
Where: PDF page 11, 4.2 Connecting the battery cables, table
[4]
Idle consumption25 W
Published value for this exact SKU: "25 W".
Where: Victron public API technical data: zeroLoadPower
[2]
Max parallel units6 count
Printed as "A maximum of six units connected in parallel" (identical devices with the same power ratings) in the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
Where: Connecting Quattros in parallel
[5]
Terminal torque11 N·m
Printed as "Maximum torque: 11 Nm" for the battery connection in the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
Where: Battery connection procedure
[5]
Communication ports2x RJ45 connector for remote panel and/or parallel and 3-phase operation
Printed as "B 2x RJ45 connector for remote panel and/or parallel and 3-phase operation" and "I Alarm contact: (left to right) NC, NO, COM" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 28).
Where: PDF page 28, Appendix A Connection overview, items B and I
[4]
Operating voltage38 to 66 V
Printed as "INVERTER Input voltage range (V DC) 38 – 66" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 25).
Where: PDF page 25, 8. Technical Specifications, Inverter, Input voltage range (V DC) row
[4]
Continuous output2.4 kW
Converted: 2,400 W / 1000 = 2.4 kW
Printed as "Cont. output power at 25 °C / 77 °F 2400 W 4000 W 8000 W" in the Victron Quattro 3kVA - 10kVA 120V datasheet, captured on September 25, 2026; the 48/3000/35-50/50 120V column reads "2400 W" (the table prints one value per power class: 3000, 5000 and 10000 VA). Recorded in kW as a change of unit of that figure.
Where: Victron Quattro 3kVA - 10kVA 120V datasheet, specification table, "Cont. output power at 25 °C / 77 °F" row, 48/3000/35-50/50 120V column
Sources
Converted: 2,400 W / 1000 = 2.4 kW
[3]
Mounting orientationThe device can be fitted either horizontally or vertically. For optimal cooling, vertical fitting is preferred.
Printed as "The device can be fitted either horizontally or vertically" and "For optimal cooling, vertical fitting is preferred" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 11).
Where: PDF page 11, 4.1 Location
[4]
Battery compatibilityLithium Ion battery compatible
Printed as "Quattro Inverter/Charger 120 V 3 kVA – 10 kVA Lithium Ion battery compatible".
Where: Quattro 3kVA - 10kVA 120V datasheet, product title
[3]
Standby consumption12 W
Printed as "Zero load power in Search mode" for the exact model column; the figure (12 W) applies to Quattro 48/3000/35-50/50 120V.
Where: Quattro 3kVA - 10kVA 120V datasheet, INVERTER table
[3]
Continuous AC output2,400 W
Published value for this exact SKU: "2,400 W".
Where: Victron public API technical data: contPowerW25
[2]
Recommended protectionDC fuse 125 A; AC-in-1 fuse or magnetic circuit breaker rated at 50 A or less
Printed as "Recommended DC fuse" in the battery table and in the AC connection instructions of the Quattro 48/3000/35-50/50 120V manual, captured on September 26, 2026.
Where: Battery connection table; AC connection
[5]
Battery voltage range[38, 66] VDC V
Published value for this exact SKU: "[38, 66] VDC".
Where: Victron public API technical data: dCInputVoltageRange
[2]
Operating temperature[-40, 65] °C °C
Published value for this exact SKU: "[-40, 65] °C".
Where: Victron public API technical data: operatingTempRange
[2]
Neutral ground requirementsThe Quattro is provided with a ground relay that automatically connects the N output to the casing if no external AC supply is available
Printed as "The Quattro is provided with a ground relay (see appendix)" and "automatically connects the N output to the casing if no external AC supply is available" in the Quattro 3k 50-50A 120V (firmware xxxx4xx) (PDF page 12). The page adds that the ground relay opens before the input safety relay closes when an external AC supply is provided.
Where: PDF page 12, 4.3 Connecting AC cables
[4]

Owner reviews

No reviews. Be the first to review this product:
Write a review

Sellers

Stock isn't shown.

StoreCheckedMore infoStore link
Amazon

4.1 (7)

Sold by BrandCentric

Price as of Nov 16, 2026, 11:25 AM PST, may change

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.

CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Checked Nov 16, 2026
More info
Price from the Amazon Creators API for the New-condition featured offer. Price checked Nov 16, 2026, 11:25 AM PST.
Amazon $1,330.70 Paid link. As an Amazon Associate we earn from qualifying purchases.
Signature Solar

4.7 (9)

Checked Nov 15, 2026
More info
Discounts and evidence

Discounts

Free shippingQualifying orders of $4,000+
Last checked Sep 23, 2026
Signature Solar · Retail buyers in the lower 48 states
View offer Paid link
Terms
  • Must spend $4,000 or more (the threshold was $3,000 on September 6, 2026).
  • Excludes out-of-stock items, terminal delivery, solar panels/pallets, large module solar panels, Chiko Carports and Chiko Ground Mounts.
  • Installer, wholesale and B2B customer groups are excluded.
  • Limited-time promotion; end date not published. Order contents and delivery route must qualify.

Checked Sep 23, 2026 · End date not published.

Signature Solar promotion terms Paid link

Evidence

One new unit at the listed price; shipping and tax are not included. · Store SKU 1593085
Price readings (7)
  • Nov 2, 2026: $1,390
  • Nov 3, 2026: $1,390
  • Nov 4, 2026: $1,390
  • Nov 5, 2026: $1,390
  • Nov 9, 2026: $1,390
  • Nov 13, 2026: $1,390
  • Nov 15, 2026: $1,390

Sources [6]

Signature Solar $1,390 Paid link
ShopSolar

1 review

Checked Nov 16, 2026
More info
List price of the exact variant with stock keeping unit QUA483021100 as published in the ShopSolar Shopify product feed on 20 September 2026. The same feed prints a compare-at price of 2199.00 US dollars for this variant. One unit as listed; shipping, sales tax, permitting and installation are extra. · Store SKU QUA483021100
Price readings (34)
  • Sep 20, 2026: $1,715.30
  • Sep 24, 2026: $1,715.30
  • Sep 25, 2026: $1,715.30
  • Sep 28, 2026: $1,715.30
  • Sep 30, 2026: $1,715.30
  • Oct 2, 2026: $1,715.30
  • Oct 4, 2026: $1,715.30
  • Oct 5, 2026: $1,715.30
  • Oct 6, 2026: $1,715.30
  • Oct 11, 2026: $1,715.30
  • Oct 13, 2026: $1,715.30
  • Oct 15, 2026: $1,715.30
  • Oct 16, 2026: $1,715.30
  • Oct 17, 2026: $1,715.30
  • Oct 20, 2026: $1,715.30
  • Oct 22, 2026: $1,715.30
  • Oct 23, 2026: $1,715.30
  • Oct 25, 2026: $1,715.30
  • Oct 26, 2026: $1,715.30
  • Oct 28, 2026: $1,715.30
  • Oct 29, 2026: $1,715.30
  • Oct 30, 2026: $1,715.30
  • Oct 31, 2026: $1,715.30
  • Nov 1, 2026: $1,715.30
  • Nov 2, 2026: $1,715.30
  • Nov 3, 2026: $1,715.30
  • Nov 4, 2026: $1,715.30
  • Nov 5, 2026: $1,715.30
  • Nov 6, 2026: $1,715.30
  • Nov 8, 2026: $1,715.30
  • Nov 12, 2026: $1,715.30
  • Nov 13, 2026: $1,715.30
  • Nov 15, 2026: $1,715.30
  • Nov 16, 2026: $1,715.30

Sources [7]

ShopSolar $1,715.30 Paid link

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.

CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Price history

Prices we read at ShopSolar and Signature Solar · 42 readings from to

Chart, listings & data

Since · Listing price (USD)

View listing at ShopSolar Paid link
View listing at Signature Solar Paid link
$1,250$1,500$1,750$2,000ShopSolar: $1,715.30 · Sep 20, 2026, 7:50 AM PDTShopSolar: $1,715.30 · Sep 24, 2026, 2:31 AM PDTShopSolar: $1,715.30 · Sep 25, 2026, 3:02 AM PDTShopSolar: $1,715.30 · Sep 28, 2026, 2:03 AM PDTShopSolar: $1,715.30 · Sep 30, 2026, 1:05 AM PDTShopSolar: $1,715.30 · Oct 2, 2026, 4:02 AM PDTShopSolar: $1,715.30 · Oct 4, 2026, 3:00 AM PDTShopSolar: $1,715.30 · Oct 5, 2026, 1:05 AM PDTShopSolar: $1,715.30 · Oct 6, 2026, 1:05 AM PDTShopSolar: $1,715.30 · Oct 11, 2026, 1:05 AM PDTShopSolar: $1,715.30 · Oct 13, 2026, 1:15 AM PDTShopSolar: $1,715.30 · Oct 15, 2026, 1:06 AM PDTShopSolar: $1,715.30 · Oct 16, 2026, 1:06 AM PDTShopSolar: $1,715.30 · Oct 17, 2026, 1:16 AM PDTShopSolar: $1,715.30 · Oct 20, 2026, 9:18 PM PDTShopSolar: $1,715.30 · Oct 22, 2026, 1:16 AM PDTShopSolar: $1,715.30 · Oct 23, 2026, 3:10 AM PDTShopSolar: $1,715.30 · Oct 25, 2026, 1:06 AM PDTShopSolar: $1,715.30 · Oct 26, 2026, 1:07 AM PDTShopSolar: $1,715.30 · Oct 28, 2026, 1:26 AM PDTShopSolar: $1,715.30 · Oct 29, 2026, 1:16 AM PDTShopSolar: $1,715.30 · Oct 30, 2026, 1:26 AM PDTShopSolar: $1,715.30 · Oct 31, 2026, 1:27 AM PDTShopSolar: $1,715.30 · Nov 1, 2026, 1:07 AM PDTShopSolar: $1,715.30 · Nov 2, 2026, 1:36 AM PSTShopSolar: $1,715.30 · Nov 3, 2026, 1:07 AM PSTShopSolar: $1,715.30 · Nov 4, 2026, 1:07 AM PSTShopSolar: $1,715.30 · Nov 5, 2026, 1:06 AM PSTShopSolar: $1,715.30 · Nov 6, 2026, 1:07 AM PSTShopSolar: $1,715.30 · Nov 8, 2026, 1:16 AM PSTShopSolar: $1,715.30 · Nov 12, 2026, 1:26 AM PSTShopSolar: $1,715.30 · Nov 13, 2026, 1:07 AM PSTShopSolar: $1,715.30 · Nov 15, 2026, 12:06 AM PSTShopSolar: $1,715.30 · Nov 16, 2026, 12:25 AM PSTSignature Solar: $1,390 · Nov 2, 2026, 9:07 AM PSTSignature Solar: $1,390 · Nov 3, 2026, 2:01 AM PSTSignature Solar: $1,390 · Nov 4, 2026, 3:31 AM PSTSignature Solar: $1,390 · Nov 5, 2026, 4:42 AM PSTSignature Solar: $1,390 · Nov 9, 2026, 2:00 AM PSTSignature Solar: $1,390 · Nov 13, 2026, 2:01 AM PSTSignature Solar: $1,390 · Nov 15, 2026, 4:54 AM PSTSep 20, 2026Nov 16, 2026
ShopSolar$1,715.30Nov 16, 2026, 12:25 AM PSTLatest check · hover or tap for earlier prices

A break in a line is a gap in our readings: no price is drawn for days we did not read.

Price data
Collected price observations by seller
CheckedSellerPrice
Nov 16, 2026, 12:25 AM PSTShopSolar Paid link$1,715.30
Nov 15, 2026, 4:54 AM PSTSignature Solar Paid link$1,390
Nov 15, 2026, 12:06 AM PSTShopSolar Paid link$1,715.30
Nov 13, 2026, 2:01 AM PSTSignature Solar Paid link$1,390
Nov 13, 2026, 1:07 AM PSTShopSolar Paid link$1,715.30
Nov 12, 2026, 1:26 AM PSTShopSolar Paid link$1,715.30
Nov 9, 2026, 2:00 AM PSTSignature Solar Paid link$1,390
Nov 8, 2026, 1:16 AM PSTShopSolar Paid link$1,715.30
Nov 6, 2026, 1:07 AM PSTShopSolar Paid link$1,715.30
Nov 5, 2026, 4:42 AM PSTSignature Solar Paid link$1,390
Nov 5, 2026, 1:06 AM PSTShopSolar Paid link$1,715.30
Nov 4, 2026, 3:31 AM PSTSignature Solar Paid link$1,390
Nov 4, 2026, 1:07 AM PSTShopSolar Paid link$1,715.30
Nov 3, 2026, 2:01 AM PSTSignature Solar Paid link$1,390
Nov 3, 2026, 1:07 AM PSTShopSolar Paid link$1,715.30
Nov 2, 2026, 9:07 AM PSTSignature Solar Paid link$1,390
Nov 2, 2026, 1:36 AM PSTShopSolar Paid link$1,715.30
Nov 1, 2026, 1:07 AM PDTShopSolar Paid link$1,715.30
Oct 31, 2026, 1:27 AM PDTShopSolar Paid link$1,715.30
Oct 30, 2026, 1:26 AM PDTShopSolar Paid link$1,715.30
Oct 29, 2026, 1:16 AM PDTShopSolar Paid link$1,715.30
Oct 28, 2026, 1:26 AM PDTShopSolar Paid link$1,715.30
Oct 26, 2026, 1:07 AM PDTShopSolar Paid link$1,715.30
Oct 25, 2026, 1:06 AM PDTShopSolar Paid link$1,715.30
Oct 23, 2026, 3:10 AM PDTShopSolar Paid link$1,715.30
Oct 22, 2026, 1:16 AM PDTShopSolar Paid link$1,715.30
Oct 20, 2026, 9:18 PM PDTShopSolar Paid link$1,715.30
Oct 17, 2026, 1:16 AM PDTShopSolar Paid link$1,715.30
Oct 16, 2026, 1:06 AM PDTShopSolar Paid link$1,715.30
Oct 15, 2026, 1:06 AM PDTShopSolar Paid link$1,715.30
Oct 13, 2026, 1:15 AM PDTShopSolar Paid link$1,715.30
Oct 11, 2026, 1:05 AM PDTShopSolar Paid link$1,715.30
Oct 6, 2026, 1:05 AM PDTShopSolar Paid link$1,715.30
Oct 5, 2026, 1:05 AM PDTShopSolar Paid link$1,715.30
Oct 4, 2026, 9:30 AM PDTShopSolar Paid link$1,715.30
Oct 4, 2026, 3:00 AM PDTShopSolar Paid link$1,715.30
Oct 2, 2026, 4:02 AM PDTShopSolar Paid link$1,715.30
Sep 30, 2026, 1:05 AM PDTShopSolar Paid link$1,715.30
Sep 28, 2026, 2:03 AM PDTShopSolar Paid link$1,715.30
Sep 25, 2026, 3:02 AM PDTShopSolar Paid link$1,715.30
Sep 24, 2026, 2:31 AM PDTShopSolar Paid link$1,715.30
Sep 20, 2026, 7:50 AM PDTShopSolar Paid link$1,715.30
Show more

Evidence score

9/100Missing details40% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.

[8]

Idle consumption25 W3.2 / 10.0

25 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart

Published value for this exact SKU: "25 W".

[2]

Research pending, 0 points: Certificates, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
EN-IEC 60335-1manufacturer claimunknown[2]
Scope
equipment listing
Covered models
QUA483021100
Limitations
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[2]
EN-IEC 60335-2-29manufacturer claimunknown[2]
Scope
equipment listing
Covered models
QUA483021100
Limitations
Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[2]
EN-IEC 62109-1manufacturer claimunknown[2]
Scope
equipment listing
Covered models
QUA483021100
Limitations
Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[2]

Warranty

FieldValueConditionsSource
RemedyRepair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[8]
ConditionsVoid after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[8]
Start basisDate of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[8]
Warranty term5 years
Brand-wide Victron policy; names no model
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
[8]
Labor and shippingNot included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
[8]
Extended warranty5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
[8]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Quattro 48/3000/35-50/50 120V manual (firmware xxxx400 or higher)Official · Victron Energy · Official installation manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: 4.2 Battery connection; 4.3 AC connection; parallel connection

    Retrieved Sep 25, 2026

    Victron Energy's own manual for the Quattro 48/3000/35-50/50 120V, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.89 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Manual-Quattro-3k-50-50A-120V-%28firmware-xxxx4xx%29-EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    36

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 1eb97868dd0235333f99b3ef2f58807c65785553087ea69ce8e2b57eb5bc16d1

    Open
  • Datasheets

  • Quattro 3kVA - 10kVA 120VOfficial · Victron Energy · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron document library entry 1200 (Datasheet).

    Location: Datasheet-Quattro-3-10kVA-120V-EN-.pdf

    Retrieved Sep 18, 2026

    Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs QUA125021100, QUA245023110, QUA483021100, QUA485021100, QUA483100100, QUA483100102, QUA482501102. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.

    SHA-256: d265bddc77ddcf34c6a2c6c00e0735a36e42499cb842ff1407a19f61814addf1

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.02 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-Quattro-3-10kVA-120V-EN-.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    None

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d265bddc77ddcf34c6a2c6c00e0735a36e42499cb842ff1407a19f61814addf1

    Open
  • Warranty

  • Victron Energy victron warrantyOfficial · Victron Energy · Official warranty · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Retrieved Sep 10, 2026

    SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.11 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

    Open
  • Other documents

  • Modbus-TCP register listOfficial · Victron Energy · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Open
  • Victron Energy price list 2026-Q3 (EUR C, web edition)Official · Victron Energy B.V. · Official document · PDF
    Source details
    Revision
    2026-Q3
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.

    Location: Rows by article number

    Retrieved Sep 22, 2026

    Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.

    Archived copies

    Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup2026-Q3 · 1.84 MB

    Archived copy, unaltered, kept as a record of what Victron Energy B.V. published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    20

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50

    Open

Archive and older revisions

Archive and older revisions9

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • Marine Integration GuideOfficial · Victron Energy · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Open
  • Adaptive charging - How does it work?Official · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 3b45b21b5fb70f99517be6dea9fe9e1effb00595ea7c1f32024497e21d3d231a

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.10 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Adaptive_charging_how_it_works.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 3b45b21b5fb70f99517be6dea9fe9e1effb00595ea7c1f32024497e21d3d231a

    Open
  • The Energy Unlimited bookOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 647ce3b98bcea87ec1f6898073097d313dddb4d16cf67be83652668516ba3178

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.59 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Book-Energy-Unlimited-EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    73

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 647ce3b98bcea87ec1f6898073097d313dddb4d16cf67be83652668516ba3178

    Open
  • Engine driven inverter systemOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 2b52dcaab7e461509d38bc9002e66b71042f3e74116ca41b06524964269d1de7

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.26 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Engine-driven-inverter-system.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 2b52dcaab7e461509d38bc9002e66b71042f3e74116ca41b06524964269d1de7

    Open
  • Interfacing with VE Bus products - MK2 protocolOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 95e593e288a0107ce6b2fad44c1e9e5828e37795b57bb15b468e23ff5040203c

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.27 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Interfacing-with-VE-Bus-products-MK2-Protocol-3-14.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    34

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 95e593e288a0107ce6b2fad44c1e9e5828e37795b57bb15b468e23ff5040203c

    Open
  • Marine Generator Test 2007 - Test ReportOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 23fb52268464408fe25e8af435fef039f7b23075bba523752362f19d05352cd1

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.68 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/VE_Marine_generator_test_RVA_07-jan-2008.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    68

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 23fb52268464408fe25e8af435fef039f7b23075bba523752362f19d05352cd1

    Open
  • Reducing cost of Off-grid Telecom BTSOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: aa22474bf7b62e079255cf4b3b789bffbe4226842129398cc301621f7fa46d42

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.08 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-telecom-How-to-reduce-the-cost-of-supplying-power-to-an-off-grid-BTS-EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    4

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: aa22474bf7b62e079255cf4b3b789bffbe4226842129398cc301621f7fa46d42

    Open
  • Achieving the impossibleOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 8354940b58a4c545bdbd8ddb5b36c732b3807c2852e19d7d6766934658ba03b3

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 1.84 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Achieving-the-impossible-EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    11

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 8354940b58a4c545bdbd8ddb5b36c732b3807c2852e19d7d6766934658ba03b3

    Open
  • Data communication with Victron Energy productsOfficial · Victron Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    Location: Document title as published

    Retrieved Sep 19, 2026

    Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.

    SHA-256: 1523c0894e00d385647f8bd8bbc7cbee29e9ef32f1bd376f148e5882351814b1

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.39 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Data-communication-with-Victron-Energy-products_EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    13

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 1523c0894e00d385647f8bd8bbc7cbee29e9ef32f1bd376f148e5882351814b1

    Open

Archived documents

Victron Energy reference document

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup2026 Q3 Euro C · 1.84 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
20

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50

Quattro 3kVA - 10kVA 120V

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.02 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-Quattro-3-10kVA-120V-EN-.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d265bddc77ddcf34c6a2c6c00e0735a36e42499cb842ff1407a19f61814addf1

Quattro 3k 50-50A 120V (firmware xxxx4xx)

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.89 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Manual-Quattro-3k-50-50A-120V-(firmware-xxxx4xx)-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 1eb97868dd0235333f99b3ef2f58807c65785553087ea69ce8e2b57eb5bc16d1

Declaration of Conformity - Quattro & Quattro-II

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.10 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Quattro(-II)-2023-12-08.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3534738dbfd8f7a435f6613d8838411cc8bb3c1c306d738d9bf275e29f187e36

Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.43 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Certificate-Safety-RETIE-40117-All-MultiPlus(-II)-and-Quattro(-II)-120V-(Colombia).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: cb642d7affe049dd745f8b9e210373941c108684c460471e21ea638d2aee965a

ISO9001 certificate

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.09 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3ff038f55f2046ed333f2193435282404d97fae6077f92597f31aad694604c71

Adaptive charging - How does it work?

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.10 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Adaptive_charging_how_it_works.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3b45b21b5fb70f99517be6dea9fe9e1effb00595ea7c1f32024497e21d3d231a

The Energy Unlimited book

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.59 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Book-Energy-Unlimited-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
73

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 647ce3b98bcea87ec1f6898073097d313dddb4d16cf67be83652668516ba3178

Engine driven inverter system

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.26 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Engine-driven-inverter-system.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 2b52dcaab7e461509d38bc9002e66b71042f3e74116ca41b06524964269d1de7

Interfacing with VE Bus products - MK2 protocol

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.27 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Interfacing-with-VE-Bus-products-MK2-Protocol-3-14.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
34

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 95e593e288a0107ce6b2fad44c1e9e5828e37795b57bb15b468e23ff5040203c

Marine Generator Test 2007 - Test Report

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.68 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/VE_Marine_generator_test_RVA_07-jan-2008.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
68

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 23fb52268464408fe25e8af435fef039f7b23075bba523752362f19d05352cd1

Reducing cost of Off-grid Telecom BTS

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.08 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-telecom-How-to-reduce-the-cost-of-supplying-power-to-an-off-grid-BTS-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
4

Embedded dates are file metadata, not independent proof of publication.

SHA-256: aa22474bf7b62e079255cf4b3b789bffbe4226842129398cc301621f7fa46d42

Achieving the impossible

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.84 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Achieving-the-impossible-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
11

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8354940b58a4c545bdbd8ddb5b36c732b3807c2852e19d7d6766934658ba03b3

Data communication with Victron Energy products

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.39 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Technical-Information-Data-communication-with-Victron-Energy-products_EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
13

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 1523c0894e00d385647f8bd8bbc7cbee29e9ef32f1bd376f148e5882351814b1

Victron Energy victron warranty

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.11 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

Submit a document

Matched on printed specifications

The manufacturer names it

Show all 12

These are the manufacturers’ claims.

Nominal voltage in range

Show all 12
View all 851 batteries in this range

Order: products a manufacturer names first, then by Evidence score at default weights.

Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Quattro 48/3000/35-50/50 120V

Manufacturer SKU QUA483021100

  1. Observed Sep 18, 2026

    EN-IEC 60335-1: claimed

    Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.

    [2]

  2. Observed Sep 18, 2026

    EN-IEC 60335-2-29: claimed

    Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.

    [2]

  3. Observed Sep 18, 2026

    EN-IEC 62109-1: claimed

    Product / system scope unresolved. Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU QUA483021100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.

    [2]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 40
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: EN-IEC 60335-1 +2
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [8]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 25
unit: Unknown
shown: 25 W
shown detail: Unknown
state: documented
points: 3.2
ceiling: 10
weight: 10
share: 32
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Victron Energy price list 2026-Q3 (EUR C, web edition) (Victron Energy B.V. · manufacturer · 2026-Q3 · observed Sep 22, 2026)
  2. Victron Energy public API record for SKU QUA483021100 (Quattro) (Victron Energy · manufacturer · Victron record modified 2026-09-04 19:09:18 · observed Sep 18, 2026)
  3. Quattro 3kVA - 10kVA 120V (Victron Energy · manufacturer · observed Sep 18, 2026)
  4. Quattro 3k 50-50A 120V (firmware xxxx4xx) (Victron Energy · manufacturer · observed Sep 18, 2026)
  5. Quattro 48/3000/35-50/50 120V manual (firmware xxxx400 or higher) (Victron Energy · manufacturer · observed Sep 25, 2026)
  6. Victron Quattro 48/3000 | 48V Input | 3000W Output 120V | 35A Charger | Transfer Switch (signaturesolar.com, November 2, 2026 capture) Paid link (Signature Solar · seller · observed Nov 2, 2026)
  7. ShopSolar store product feed, page 4 (October 4, 2026 capture) Paid link (ShopSolar · seller · observed Oct 4, 2026)
  8. Victron Energy victron warranty (Victron Energy · manufacturer · observed Sep 10, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details