Victron Energy's 2026-Q3 price list prints article number PMP482505110 on the row for "MultiPlus-II 48/5000/70-95 120V" (page 4), this record's product.
Location: Victron Energy price list 2026-Q3, page 4, row "MultiPlus-II 48/5000/70-95 120V" PMP482505110
Documented
Grounding (manual)
This product is a safety class I device (supplied with a ground terminal for safety purposes).; Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes.; An additional grounding point is located on the product's exterior.
Printed as "This product is a safety class I device" and "Its AC input and/or output terminals must be provided with uninterruptible grounding" and "An additional grounding point is located on the product's exterior" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 4). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "Peak power 5500 W 6kW/2s 5500 W 5500 W 9000 W 9000 W" in the Victron MultiPlus-II 120V datasheet, captured on September 25, 2026; the 48/5000/70-95 column reads "9000 W".
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 30). Output voltage in inverter mode, common to both models in the table. The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "Peak power 5500 W 6kW/2s 5500 W 5500 W 9000 W 9000 W" in the Victron MultiPlus-II 120V datasheet, captured on September 25, 2026; the 48/5000/70-95 column reads "9000 W".
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 30). Output voltage in inverter mode, common to both models in the table. The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "CHARGER AC Input Single phase: 90-140VAC 45-65Hz" and "Maximum battery charge current (3) 95A 70A" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 31). Charger section, AC input; note 3 reads "Up to 75°F / 25°C ambient". The columns are 24/5000/120-95 and 48/5000/70-95 in that order. The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Location: Victron public API technical data: maxAcInputCurrent
Documented
Idle consumption
19 W
Victron documents print 15 W and 19 W
The MultiPlus-II 120V datasheet and Victron product data print a 15 W zero load power for the 48/5000/70-95; the MultiPlus-II 120V manual (Rev 15 - 08/2026) prints 19W. Neither document explains the difference.
Printed as "Zero load power 19 W" in the 48/5000/70-95 column of the MultiPlus-II 120V manual, captured on September 26, 2026. Revised on 26 September 2026: The manufacturer manual prints a different value; the owner decided the manual value is shown first and the recorded value stays as a cited alternative.
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 30). Common to both models in the table. The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "Cont. output power at 25°C/77°F 2400 W 3,4 kW 2400 W 2400 W 4000 W 4000 W" in the Victron MultiPlus-II 120V datasheet, captured on September 25, 2026; the 48/5000/70-95 column reads "4000 W". Recorded in kW as a change of unit of that figure.
Location: Victron public API technical data: dCInputVoltageRange
Documented
Grounding (manual)
This product is a safety class I device (supplied with a ground terminal for safety purposes).; Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes.; An additional grounding point is located on the product's exterior.
Printed as "This product is a safety class I device" and "Its AC input and/or output terminals must be provided with uninterruptible grounding" and "An additional grounding point is located on the product's exterior" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 4). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "MultiPlus-II 120V - 5k models AC-in AC-out-1 AC-Out-2 Rated current" and "Recommend fuse or circuit breaker 95 A 115 A 48 A" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 17). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Location: PDF page 17, 4.4 Connection of the AC cabling, "MultiPlus-II 120V - 5k models" table, "Recommend fuse or circuit breaker" row, AC-in column
Documented
Enclosure
IP21
Victron documents print IP22 and IP21
The Victron datasheet and product data print "Protection category IP22"; the MultiPlus-II 120V manual (captured on September 26, 2026) prints "Protection category IP21". Neither document explains the difference.
Printed as "Protection category IP21" for every model in the MultiPlus-II 120V manual, captured on September 26, 2026. Revised on 26 September 2026: The manufacturer manual prints a different value; the owner decided the manual value is shown first and the recorded value stays as a cited alternative.
Printed as "The ground conductor should be at least 4mm²" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 4). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "MultiPlus-II 120V - 5k models AC-in AC-out-1 AC-Out-2 Rated current" and "Recommend fuse or circuit breaker 95 A 115 A 48 A" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 17). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Location: PDF page 17, 4.4 Connection of the AC cabling, "MultiPlus-II 120V - 5k models" table, "Recommend fuse or circuit breaker" row, AC-out-1 and AC-Out-2 columns
Printed as "48/5000/70 200 - 800Ah 200A AWG 2/0 AWG 4/0" (cross-section per positive and negative terminal) in the MultiPlus-II 120V manual, captured on September 26, 2026.
Printed as a programmable relay "which can be set for general alarm, DC under voltage or genset start/stop function" in the MultiPlus-II 120V manual, captured on September 26, 2026.
Printed as "Model Battery capacity DC fuse" and "48/5000/70 200 - 800Ah 200A" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 16). The row reads battery capacity, then DC fuse. The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "A maximum of six units can be connected in parallel" (identical units on the same battery) in the MultiPlus-II 120V manual, captured on September 26, 2026.
Location: 4.4 Connection of the AC cabling, MultiPlus-II 120V - 5k models table
Documented
Communication ports (manual)
VE.Bus communication port: for parallel, split phase and three phase operation, remote monitoring and system integration; General purpose com. port: Yes, 2x
Printed as "VE.Bus communication port For parallel, split phase and three phase operation" and "General purpose com. port (6) Yes, 2x" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 31). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as "The inverter/charger is suitable for wall mounting" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 14). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Printed as the "DC fuse" column of the battery table and "Recommend fuse or circuit breaker" row of the AC table in the MultiPlus-II 120V manual, captured on September 26, 2026.
Location: Victron public API technical data: operatingTempRange
Documented
Neutral / grounding (manual)
A ground relay (relay H) automatically connects the Neutral output to the chassis if no external AC supply is available; if an external AC supply is provided, ground relay H opens before the input safety relay closes.
Printed as "automatically connects the Neutral output to the chassis if no external AC supply is available" and "the ground relay H will open before the input safety relay closes" in the Victron Energy MultiPlus-II 120V manual (Rev 15 - 08/2026) (PDF page 17). The manual names this model in its dimension drawings as "PMP482505110 MultiPlus-II 48/5000/70-95 120V" (PDF page 42).
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs PMP482305100, PMP122305110, PMP122305120, PMP242305100, PMP122305122, PMP482305102, PMP242305102, PMP482505110, PMP242505110. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Location: 4.3 Connection of battery cables; 4.4 Connection of the AC cabling; 7 Technical specifications
Retrieved
Victron Energy's own installation and user manual for the MultiPlus-II 120V family, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Victron Energy price list 2026-Q3 (EUR C, web edition)OfficialVictron Energy B.V.Official document
Source details
Revision
2026-Q3
Revision date
Not stated
Location: Rows by article number
Retrieved
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
PDF
Current Transformer for MultiPlus-IIOfficialVictron EnergyOfficial datasheet
Source details
Revision
Not stated
Revision date
Not stated
Victron document library entry 12146 (Datasheet).
Location: Datasheet-Current-transformer-EN.pdf
Retrieved
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs PMP482505010, PMP482305010, PMP242305010, PMP482305100, PMP482805000, PMP122305010, PMP483105000, PMP242505010, PMP122305110, PMP122305120, PMP242305100, PMP483150000, PMP122305122, PMP482305102, PMP482305012, PMP482505012, PMP242305102, PMP482505110, PMP122505010, PMP242505110, PMP122505012, PMP482405012, PMP482605012, PMP482505300, PMP482505120. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Certificate UL 1741 and CSA C22.2 - MultiPlus-II 48V 5kVA 120V
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Declaration of Conformity - DIN 14679 - MultiPlus-II, Orion, BSC IP22/IP65/IP67
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Certificate Safety RETIE 40117 - All MultiPlus(-II) and Quattro(-II) 120V (Colombia)
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Certificate Safety UL 458 - MultiPlus-II 48V 5000VA 120V
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Location: Victron Energy Limited Warranty Policy, Warranty section
Documented
Coverage conditions
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Location: Victron Energy Limited Warranty Policy, Warranty section
Documented
Product warranty
5 years
Brand-wide Victron policy; names no model Unconditional, scored. Not scored: 5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends.Official warrantySources
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
DYI install February 2025. Split phase configuration with 6 x Pytes V.5 batteries, Cerbo GX and EG4 Chargeverter. System has been rock solid with no issues.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
5 years unconditional (not scored: 5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends).
19 W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band, printed by the maker: Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.
Printed as "Zero load power 19 W" in the 48/5000/70-95 column of the MultiPlus-II 120V manual, captured on September 26, 2026. Revised on 26 September 2026: The manufacturer manual prints a different value; the owner decided the manual value is shown first and the recorded value stays as a cited alternative.
The maker's documents disagree; the less favorable printed figure, 19 W, is scored. Warning: Victron documents print 15 W and 19 W
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
CSA C22.2 107.1-16Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "CSA C22.2 107.1-16" in its safety field for exact SKU PMP482505110, and a manufacturer-hosted certificate document (Certificate UL 1741 and CSA C22.2 - MultiPlus-II 48V 5kVA 120V) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
EN-IEC 60335-1Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PMP482505110. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
EN-IEC 60335-2-29Product / system scope unresolvedClaimedStatus unconfirmed
Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU PMP482505110. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
MultiPlus-II 48/5000/70-95 120V
Manufacturer SKU PMP482505110
Observed
CSA C22.2 107.1-16: claimed
Product / system scope unresolved. Victron's public API records "CSA C22.2 107.1-16" in its safety field for exact SKU PMP482505110, and a manufacturer-hosted certificate document (Certificate UL 1741 and CSA C22.2 - MultiPlus-II 48V 5kVA 120V) lists this SKU. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PMP482505110. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU PMP482505110. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.