Charged ReviewsSaved 0Compare 0Login
Victron Energy MultiPlus-II 12/3000/120-50 2x120V
Victron Energy
Inverter charger

Victron Energy MultiPlus-II 12/3000/120-50 2x120V

Key specs

Weight22 kg / 49 lb converted
Nominal voltage12 V
Efficiency93 %
Continuous output2.4 kW
Converted: 2,400 W / 1000 = 2.4 kW
Max charge120 A
AC frequency60 Hz
Victron Energy MultiPlus-II 12/3000/120-50 2x120Vread Nov 14, 2026

All specifications

Identity

BrandVictron Energy · Website
ModelMultiPlus-II 12/3000/120-50 2x120V
MarketUnknown
Manufacturer SKUPMP122305100
SKU detail
locator: Victron Energy price list 2026-Q3, page 4, row "MultiPlus-II 12/3000/120-50 2x120V" PMP122305100
conditions: Victron Energy's 2026-Q3 price list prints article number PMP122305100 on the row for "MultiPlus-II 12/3000/120-50 2x120V" (page 4), this record's product.
Sources: [1]
FieldValueConditionsSource
GroundingThis product is a safety class I device (supplied with a ground terminal for safety purposes).; Its AC input and/or output terminals must be provided with uninterruptible grounding for safety purposes.; An additional grounding point is located on the product's exterior.
Printed as "This product is a safety class I device" and "Its AC input and/or output terminals must be provided with uninterruptible grounding" and "An additional grounding point is located on the product's exterior" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 4). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 4, 1. Important safety instructions, Installation
[2]
Weight22 kg / 49 lb converted
Published value for this exact SKU: "22 kg".
Where: Victron public API technical data: weight
[3]
Peak output5500 W
Printed as "Peak power 5500 W 6kW/2s 5500 W" in the Victron MultiPlus-II 2x120V datasheet, captured on September 25, 2026; the 12/3000/120-50 column reads "5500 W".
Where: Victron MultiPlus-II 2x120V datasheet, specification table, "Peak power" row, 12/3000/120-50 column
[4]
AC voltage120VAC ± 2%
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 28). Output voltage in inverter mode, common to all models in the table; the enclosure rows print a "120/240 V AC-connection". The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 28, 7. Technical specifications, Inverter, "Output in inverter mode" row
[2]
Max charge120 A
Published value for this exact SKU: "120 A".
Where: Victron public API technical data: maximumBatteryChargeCurrent
[3]
DimensionsW 275 × H 578 × D 148 mm / W 10.8 × H 22.8 × D 5.83 in converted
Published enclosure dimensions for this exact SKU: height 578 mm, width 275 mm, depth 148 mm. Mounting clearances are separate.
Where: Victron public API technical data: height, width, depth
[3]
CommunicationsVE.Bus
Published value for this exact SKU: "VE.Bus".
Where: Victron public API technical data: communicationPort
[3]
Efficiency93 %
Published value for this exact SKU: "93 %".
Where: Victron public API technical data: maxEfficiency
[3]
AC frequency60 Hz
Published value for this exact SKU: "60 Hz".
Where: Victron public API technical data: aCOutputFrequency
[3]
Max AC charge120 A
Printed as "Maximum battery charge current (4) 120 A 160 A 70 A" and "CHARGER AC Input Split phase: 180-280 VAC" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 28). Charger section, AC input. The columns are 12/3000/120-50, 12/4k/160-50 and 24/3000/70-50 in that order. The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 28, 7. Technical specifications, Charger, "Maximum battery charge current" row, 12/3000/120-50 column
[2]
AC configuration120 VAC
Printed as "Output when in inverter mode Output voltage: 120 VAC ± 2 %" in the Victron MultiPlus-II 2x120V datasheet, captured on September 25, 2026; the 12/3000/120-50 column reads "120 VAC ± 2 %"; the datasheet is titled "MultiPlus-II 2x120 V".
Where: Victron MultiPlus-II 2x120V datasheet, specification table, "Output voltage" row, 12/3000/120-50 column
[4]
AC input breakerAC-in: 50 A fuse or circuit breaker
Printed as "MultiPlus-II 2x120V AC-in AC-out-1 AC-out-2 Rated current" and "Recommend fuse or circuit breaker 50 A 75 A 50 A" and "fuse or magnetic circuit breaker rated at 50A or less" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 16). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 16, 4.4 Connection of the AC cabling, AC terminal table, "Recommend fuse or circuit breaker" row, AC-in column
[2]
Enclosure ratingIP22
Published value for this exact SKU: "IP22".
Where: Victron public API technical data: protectionCategory
[3]
Ground wire sizeAt least 4mm²
Printed as "The ground conductor should be at least 4mm²" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 4). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 4, 1. Important safety instructions, Installation
[2]
AC output breakerAC-out-1: 75 A; AC-out-2: 50 A (fuse or circuit breaker)
Printed as "MultiPlus-II 2x120V AC-in AC-out-1 AC-out-2 Rated current" and "Recommend fuse or circuit breaker 50 A 75 A 50 A" and "The maximum rating of the fuse or circuit breaker is 75A" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 16). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 16, 4.4 Connection of the AC cabling, AC terminal table, "Recommend fuse or circuit breaker" row, AC-out-1 and AC-out-2 columns
[2]
Apparent power3,000 VA
Published value for this exact SKU: "3,000 VA".
Where: Victron public API technical data: contPowerVA25
[3]
Battery wire size2x AWG 1/0 (cables 0 to 5 m); 2x AWG 2/0 (5 to 10 m)
Printed as "12/3000/120 400 - 1200Ah 400A 2x AWG 1/0 2x AWG 2/0" (cross-section per positive and negative terminal) in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.3 Connection of battery cables, table
[2]
Generator supportProgrammable relay can be set for genset start/stop
Printed as a programmable relay "which can be set for general alarm, DC under voltage or genset start/stop function" in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.5 Optional connections, programmable relay; 7 Technical specifications note
[2]
Nominal voltage12 V
Published value for this exact SKU: "12 V".
Where: Victron public API technical data: batteryVoltageNominal
[3]
Surge AC output5,500 W
Published value for this exact SKU: "5,500 W".
Where: Victron public API technical data: peakPowerRating
[3]
AC input wire sizeAWG 6 minimum
Printed as the "Minimum wire gauge" row (three-wire 90ºC copper cable) in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.4 Connection of the AC cabling, MultiPlus-II 2x120V table
[2]
Battery protectionDC fuse 400A
Printed as "Model Battery capacity DC fuse" and "12/3000/120 400 - 1200Ah 400A" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 15). The row reads battery capacity, then DC fuse. The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 15, 4.3 Connection of battery cables, table, "DC fuse" column, 12/3000/120 row
[2]
Grid passthrough50 A
Published value for this exact SKU: "50 A".
Where: Victron public API technical data: maxAcInputCurrent
[3]
Idle consumption15 W
Published value for this exact SKU: "15 W".
Where: Victron public API technical data: zeroLoadPower
[3]
Max parallel units6 count
Printed as "A maximum of six units can be connected in parallel" (identical units on the same battery) in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.5.7 Parallel connection
[2]
Terminal torque12 N·m
Printed as "Recommended torque: 12 Nm (M8 nut)" for the battery cable nuts in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.3 Connection of battery cables, connection procedure
[2]
AC output voltage120 V
Printed as "Output in inverter mode Output voltage: 120VAC ± 2%" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 28). Common to all models in the table. The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 28, 7. Technical specifications, Inverter, "Output in inverter mode" row
[2]
AC output wire sizeAWG 6 minimum (AC-out-1); AWG 6 minimum (AC-out-2)
Printed as the "Minimum wire gauge" row (three-wire 90ºC copper cable) in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.4 Connection of the AC cabling, MultiPlus-II 2x120V table
[2]
Communication portsVE.Bus communication port: for parallel and three phase operation, remote monitoring and system integration; General purpose communication port: Yes, 2x
Printed as "VE.Bus communication port For parallel and three phase operation" and "General purpose communication port (7) Yes, 2x" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 28). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 28, 7. Technical specifications, General
[2]
Operating voltage9.5 to 17 V
Printed as "INVERTER DC Input voltage range 9.5 – 17V 9.5 -17V 19 - 33V" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 28). The columns are 12/3000/120-50, 12/4k/160-50 and 24/3000/70-50 in that order. The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 28, 7. Technical specifications, Inverter, "DC Input voltage range" row, 12/3000/120-50 column
[2]
Continuous output2.4 kW
Converted: 2,400 W / 1000 = 2.4 kW
Printed as "Cont. output power at 25°C/77°F 2400 W 3,4 kW 2400 W" in the Victron MultiPlus-II 2x120V datasheet, captured on September 25, 2026; the 12/3000/120-50 column reads "2400 W". Recorded in kW as a change of unit of that figure.
Where: Victron MultiPlus-II 2x120V datasheet, specification table, "Cont. output power at 25°C/77°F" row, 12/3000/120-50 column
Sources
Converted: 2,400 W / 1000 = 2.4 kW
[4]
Mounting orientationSuitable for wall mounting
Printed as "The inverter/charger is suitable for wall mounting" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 13). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 13, 4.1 Location
[2]
Continuous AC output2,400 W
Published value for this exact SKU: "2,400 W".
Where: Victron public API technical data: contPowerW25
[3]
Recommended protectionDC fuse 400 A; AC-in 50 A, AC-out-1 75 A, AC-out-2 50 A fuse or circuit breaker
Printed as the "DC fuse" column of the battery table and "Recommend fuse or circuit breaker" row of the AC table in the MultiPlus-II 2x120V manual, captured on September 26, 2026.
Where: 4.3 battery table and 4.4 MultiPlus-II 2x120V table
[2]
Battery voltage range[9.5, 17] VDC V
Published value for this exact SKU: "[9.5, 17] VDC".
Where: Victron public API technical data: dCInputVoltageRange
[3]
Operating temperature[-40, 65] °C °C
Published value for this exact SKU: "[-40, 65] °C".
Where: Victron public API technical data: operatingTempRange
[3]
Neutral ground requirementsA ground relay (relay H) automatically connects the Neutral output to the chassis if no external AC supply is available; if an external AC supply is provided, ground relay H opens before the input safety relay closes.
Printed as "automatically connects the Neutral output to the chassis if no external AC supply is available" and "the ground relay H will open before the input safety relay closes" in the Victron Energy MultiPlus-II 2x120V manual (PDF page 16). The manual names "PMP122305100 MultiPlus-II 12/3000/120-50 2x120V" in its dimension drawings (PDF page 37).
Where: PDF page 16, 4.4 Connection of the AC cabling
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

Lowest first. Each price is the date we last read it; it may have changed. Stock isn't shown.

StorePriceReadDetailsSource
ShopSolar$1,088Nov 14, 2026List price of the exact variant with stock keeping unit PMP122305100 as published in the ShopSolar Shopify product feed on 20 September 2026. The price is the one the feed prints for the variant "Victron Energy 12V 3000". The same feed prints a compare-at price of 2083.75 US dollars for this variant. One unit as listed; shipping, sales tax, permitting and installation are extra. · Store SKU PMP122305100
Price readings (31)
  • Sep 20, 2026: $1,088
  • Sep 24, 2026: $1,088
  • Sep 25, 2026: $1,088
  • Sep 28, 2026: $1,088
  • Sep 30, 2026: $1,088
  • Oct 2, 2026: $1,088
  • Oct 4, 2026: $1,088
  • Oct 5, 2026: $1,088
  • Oct 6, 2026: $1,088
  • Oct 8, 2026: $1,088
  • Oct 11, 2026: $1,088
  • Oct 13, 2026: $1,088
  • Oct 15, 2026: $1,088
  • Oct 16, 2026: $1,088
  • Oct 17, 2026: $1,088
  • Oct 20, 2026: $1,088
  • Oct 22, 2026: $1,088
  • Oct 23, 2026: $1,088
  • Oct 24, 2026: $1,088
  • Oct 25, 2026: $1,088
  • Oct 26, 2026: $1,088
  • Oct 27, 2026: $1,088
  • Oct 29, 2026: $1,088
  • Oct 31, 2026: $1,088
  • Nov 3, 2026: $1,088
  • Nov 4, 2026: $1,088
  • Nov 5, 2026: $1,088
  • Nov 6, 2026: $1,088
  • Nov 7, 2026: $1,088
  • Nov 8, 2026: $1,088
  • Nov 14, 2026: $1,088
[5]View now Paid link

Price history

Prices we read at ShopSolar · 32 readings · no change in our readings since

Chart, listings & data

Since · Listing price (USD)

View listing at ShopSolar Paid link
$1,000$1,100$1,200ShopSolar: $1,088 · Sep 20, 2026, 7:50 AM PDTShopSolar: $1,088 · Sep 24, 2026, 2:31 AM PDTShopSolar: $1,088 · Sep 25, 2026, 3:02 AM PDTShopSolar: $1,088 · Sep 28, 2026, 2:03 AM PDTShopSolar: $1,088 · Sep 30, 2026, 1:05 AM PDTShopSolar: $1,088 · Oct 2, 2026, 4:02 AM PDTShopSolar: $1,088 · Oct 4, 2026, 1:07 AM PDTShopSolar: $1,088 · Oct 5, 2026, 1:05 AM PDTShopSolar: $1,088 · Oct 6, 2026, 1:05 AM PDTShopSolar: $1,088 · Oct 8, 2026, 1:06 AM PDTShopSolar: $1,088 · Oct 11, 2026, 1:05 AM PDTShopSolar: $1,088 · Oct 13, 2026, 1:15 AM PDTShopSolar: $1,088 · Oct 15, 2026, 1:06 AM PDTShopSolar: $1,088 · Oct 16, 2026, 1:06 AM PDTShopSolar: $1,088 · Oct 17, 2026, 1:16 AM PDTShopSolar: $1,088 · Oct 20, 2026, 9:17 PM PDTShopSolar: $1,088 · Oct 22, 2026, 1:16 AM PDTShopSolar: $1,088 · Oct 23, 2026, 3:10 AM PDTShopSolar: $1,088 · Oct 24, 2026, 1:06 AM PDTShopSolar: $1,088 · Oct 25, 2026, 1:06 AM PDTShopSolar: $1,088 · Oct 26, 2026, 1:07 AM PDTShopSolar: $1,088 · Oct 27, 2026, 1:07 AM PDTShopSolar: $1,088 · Oct 29, 2026, 1:16 AM PDTShopSolar: $1,088 · Oct 31, 2026, 1:27 AM PDTShopSolar: $1,088 · Nov 3, 2026, 1:06 AM PSTShopSolar: $1,088 · Nov 4, 2026, 1:07 AM PSTShopSolar: $1,088 · Nov 5, 2026, 3:52 AM PSTShopSolar: $1,088 · Nov 6, 2026, 1:07 AM PSTShopSolar: $1,088 · Nov 7, 2026, 1:17 AM PSTShopSolar: $1,088 · Nov 8, 2026, 1:16 AM PSTShopSolar: $1,088 · Nov 14, 2026, 5:57 AM PSTSep 20, 2026Nov 14, 2026
ShopSolar$1,088Nov 14, 2026, 5:57 AM PSTLatest check · hover or tap for earlier prices

A break in a line is a gap in our readings: no price is drawn for days we did not read.

Price data
Collected price observations by seller
CheckedSellerPrice
Sep 20, 2026, 7:50 AM PDTShopSolar Paid link$1,088
Sep 24, 2026, 2:31 AM PDTShopSolar Paid link$1,088
Sep 25, 2026, 3:02 AM PDTShopSolar Paid link$1,088
Sep 28, 2026, 2:03 AM PDTShopSolar Paid link$1,088
Sep 30, 2026, 1:05 AM PDTShopSolar Paid link$1,088
Oct 2, 2026, 4:02 AM PDTShopSolar Paid link$1,088
Oct 4, 2026, 1:07 AM PDTShopSolar Paid link$1,088
Oct 4, 2026, 9:30 AM PDTShopSolar Paid link$1,088
Oct 5, 2026, 1:05 AM PDTShopSolar Paid link$1,088
Oct 6, 2026, 1:05 AM PDTShopSolar Paid link$1,088
Oct 8, 2026, 1:06 AM PDTShopSolar Paid link$1,088
Oct 11, 2026, 1:05 AM PDTShopSolar Paid link$1,088
Oct 13, 2026, 1:15 AM PDTShopSolar Paid link$1,088
Oct 15, 2026, 1:06 AM PDTShopSolar Paid link$1,088
Oct 16, 2026, 1:06 AM PDTShopSolar Paid link$1,088
Oct 17, 2026, 1:16 AM PDTShopSolar Paid link$1,088
Oct 20, 2026, 9:17 PM PDTShopSolar Paid link$1,088
Oct 22, 2026, 1:16 AM PDTShopSolar Paid link$1,088
Oct 23, 2026, 3:10 AM PDTShopSolar Paid link$1,088
Oct 24, 2026, 1:06 AM PDTShopSolar Paid link$1,088
Oct 25, 2026, 1:06 AM PDTShopSolar Paid link$1,088
Oct 26, 2026, 1:07 AM PDTShopSolar Paid link$1,088
Oct 27, 2026, 1:07 AM PDTShopSolar Paid link$1,088
Oct 29, 2026, 1:16 AM PDTShopSolar Paid link$1,088
Oct 31, 2026, 1:27 AM PDTShopSolar Paid link$1,088
Nov 3, 2026, 1:06 AM PSTShopSolar Paid link$1,088
Nov 4, 2026, 1:07 AM PSTShopSolar Paid link$1,088
Nov 5, 2026, 3:52 AM PSTShopSolar Paid link$1,088
Nov 6, 2026, 1:07 AM PSTShopSolar Paid link$1,088
Nov 7, 2026, 1:17 AM PSTShopSolar Paid link$1,088
Nov 8, 2026, 1:16 AM PSTShopSolar Paid link$1,088
Nov 14, 2026, 5:57 AM PSTShopSolar Paid link$1,088

Quick reference sheet

Continuous output
2.4 kW
Battery voltage
9.5 to 17 V
Solar input
Not statedMPPT trackers Not stated
AC output
120 VAC
Warranty
5 years
Size
23.52 L* (Calculated from published dimensions)W: 275 × H: 578 × D: 148 mm / W: 10.8 × H: 22.8 × D: 5.83 inWeight 22 kg / 49 lb

Evidence score

11/100Missing details40% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.

[6]

Idle consumption15 W5.3 / 10.0

15 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart

Published value for this exact SKU: "15 W".

[3]

Research pending, 0 points: Certificates, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
EN-IEC 60335-1manufacturer claimunknown[3]
Scope
equipment listing
Covered models
PMP122305100
Limitations
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PMP122305100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[3]
EN-IEC 60335-2-29manufacturer claimunknown[3]
Scope
equipment listing
Covered models
PMP122305100
Limitations
Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU PMP122305100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 18, 2026
Source
[3]

Warranty

FieldValueConditionsSource
RemedyRepair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[6]
ConditionsVoid after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[6]
Start basisDate of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[6]
Warranty term5 years
Brand-wide Victron policy; names no model
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
[6]
Labor and shippingNot included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
[6]
Extended warranty5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
[6]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • MultiPlus-II 2x120V manualOfficial · Victron Energy · Official installation manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: 4.3 Connection of battery cables; 4.4 Connection of the AC cabling; 7 Technical specifications

    Retrieved Sep 25, 2026

    Victron Energy's own installation and user manual for the MultiPlus-II 2x120V family, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test. The PDF prints no revision on its cover.

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.58 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/MultiPlus-II_2x120V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    42

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: a87cea7b7958e1652fae137815d1c99521ec91448ca433c59ae9cc5349429675

    Open
  • Datasheets

  • MultiPlus-II 2x120VOfficial · Victron Energy · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Victron document library entry 7077 (Datasheet).

    Location: Datasheet-MultiPlus-II-2x120V-EN-.pdf

    Retrieved Sep 18, 2026

    Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs PMP122305100, PMP122305102, PMP242305130, PMP242305132, PMP122405200. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.

    SHA-256: 5c10c68267673cefb4def711177e269c5b688329258bdc5ab08f0c31562b2b86

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.70 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-2x120V-EN-.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    None

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5c10c68267673cefb4def711177e269c5b688329258bdc5ab08f0c31562b2b86

    Open
  • Warranty

  • Victron Energy victron warrantyOfficial · Victron Energy · Official warranty · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Retrieved Sep 10, 2026

    SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.11 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

    Open
  • Other documents

  • Victron Energy price list 2026-Q3 (EUR C, web edition)Official · Victron Energy B.V. · Official document · PDF
    Source details
    Revision
    2026-Q3
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.

    Location: Rows by article number

    Retrieved Sep 22, 2026

    Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.

    Archived copies

    Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup2026-Q3 · 1.84 MB

    Archived copy, unaltered, kept as a record of what Victron Energy B.V. published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    20

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Victron Energy reference document

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup2026 Q3 Euro C · 1.84 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
20

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50

Declaration of Conformity - MultiPlus-II (GX) 3kVA, 5kVA, 8kVA, 10kVA, 15kVA

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.11 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/MultiPlus-II-(GX)-3k-5k-8k-10k-15k-2024-02-12.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: c4de529d97e8250588c19031647f2bb903e5547c8cc7510d2ea2db4418bc52d9

Certificate Safety UL 458 - MultiPlus-II 12/24/48V 3000VA 120V

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.30 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Certificate-Safety-UL-458-MultiPlus-II-12-24-48V-3000VA-120V-080525.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 85f880947e7289be4be56feee3a24b7013b95052c4bb946f62971568b3a14ae1

Certificate Safety UL 458 - MultiPlus-II 12/3000/120-50 2x 120V

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.29 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Certificate-Safety-UL-458-MultiPlus-II-12-3000-120-50-2X120V.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5edb50571cc22e89276825996c5a210e75ab9208384fd6c9eafc41dd2955e586

ISO9001 certificate

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.09 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3ff038f55f2046ed333f2193435282404d97fae6077f92597f31aad694604c71

MultiPlus-II 2x120V

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.70 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-2x120V-EN-.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5c10c68267673cefb4def711177e269c5b688329258bdc5ab08f0c31562b2b86

Victron Energy victron warranty

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.11 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

MultiPlus-II 2x120V manual

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.58 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/MultiPlus-II_2x120V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
42

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a87cea7b7958e1652fae137815d1c99521ec91448ca433c59ae9cc5349429675

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
MultiPlus-II 12/3000/120-50 2x120V

Manufacturer SKU PMP122305100

  1. Observed Sep 18, 2026

    EN-IEC 60335-1: claimed

    Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PMP122305100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.

    [3]

  2. Observed Sep 18, 2026

    EN-IEC 60335-2-29: claimed

    Product / system scope unresolved. Victron's public API records "EN-IEC 60335-2-29" in its safety field for exact SKU PMP122305100. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.

    [3]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 40
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: EN-IEC 60335-1 +1
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [6]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 15
unit: Unknown
shown: 15 W
shown detail: Unknown
state: documented
points: 5.3
ceiling: 10
weight: 10
share: 53.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [3]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Victron Energy price list 2026-Q3 (EUR C, web edition) (Victron Energy B.V. · manufacturer · 2026-Q3 · observed Sep 22, 2026)
  2. MultiPlus-II 2x120V manual (Victron Energy · manufacturer · observed Sep 25, 2026)
  3. Victron Energy public API record for SKU PMP122305100 (MultiPlus-II 2x 120V) (Victron Energy · manufacturer · Victron record modified 2026-09-04 19:05:48 · observed Sep 18, 2026)
  4. MultiPlus-II 2x120V (Victron Energy · manufacturer · observed Sep 18, 2026)
  5. ShopSolar store product feed, page 3 (October 4, 2026 capture) Paid link (ShopSolar · seller · observed Oct 4, 2026)
  6. Victron Energy victron warranty (Victron Energy · manufacturer · observed Sep 10, 2026)

Sign in to report an error on this page