This is a Safety Class I product (supplied with a protective grounding terminal).; The chassis of the product must be connected to ground, or the frame (of a vehicle) or the ground plate or hull (of a boat).
Printed as "This is a Safety Class I product (supplied with a protective grounding terminal)" and "The chassis of the product must be connected to ground" and "or the ground plate or hull (of a boat)" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 11). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 11, 4.3 Connection of the AC cabling
Printed as "Peak power (W) 2400 3000 4000 6000 10000" in the Victron Inverter 1200VA - 5000VA datasheet, captured on September 25, 2026; the 48/3000 (3000 VA class) column reads "6000" (one value per power class: 1200, 1600, 2000, 3000 and 5000 VA).
Where: Victron Inverter 1200VA - 5000VA datasheet, specification table, "Peak power (W)" row, 48/3000 (3000 VA class) column
There should be a clear space of at least 10 cm around the appliance for cooling.
Printed as "There should be a clear space of at least 10 cm around the appliance" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 9). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Printed as "Max. efficiency 12/ 24 / 48V (%) 92 / 94 92 / 94 92 / 92 93 / 94 / 95 94 / 95" in Inverter 1200VA - 5000VA, Inverter 1200VA - 5000VA datasheet, "Max. efficiency" row, 48/3000 column, 48 V figure. Revised on 1 October 2026: Victron's datasheet prints the same maximum efficiency for this model, and it ranks above the product data record.
Printed as "Frequency: 50 Hz ± 0,1%" and "1) Can be adjusted to 60Hz; 120V/60Hz on request" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 20). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 20, 8. Technical specifications, Inverter, "Output" row and note 1
Printed as "The design criteria have been to produce a true sine wave inverter" in Victron Energy's own datasheet for this model family (Inverter 1200VA - 5000VA, PDF page 1). The specification table has no output waveform row; this is the maker's description line.
Where: Victron "Inverter 1200VA - 5000VA" datasheet, introduction (SinusMax), PDF page 1; description line (the specification table prints no waveform row)
Printed as the "Recommended cross-section (mm2) per + and - connection terminal" rows, 48/3000 column, in the Inverter 3k 5k 230V manual, captured on September 26, 2026.
Where: 4.2 Connection of battery cables, 48/3000 column
Multipurpose relay which can be set for general alarm, DC undervoltage or genset start signal function
Printed as "4) Multipurpose relay which can be set for general alarm" and "DC undervoltage or genset start signal function" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 20). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 20, 8. Technical specifications, note 4
Printed as "Recommended DC fuse 400A 300A 125A" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 10). The columns are 12/3000, 24/3000 and 48/3000 in that order. The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 10, 4.2 Connection of battery cables, "Recommended DC fuse" row, 48/3000 column
Three-wire cable with a flexible core and a cross section of 2.5 or 4 mm²
Printed as "three-wire cable with a flexible core and a cross section of 2.5 or 4 mm²" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 11). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 11, 4.3 Connection of the AC cabling
Printed as "Input voltage range (V DC) 9,5 – 17 19 – 33 38 – 66" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 20). The columns are 12/3000, 24/3000 and 48/3000 in that order. The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 20, 8. Technical specifications, Inverter, "Input voltage range (V DC)" row, 48/3000 column
Printed as "Cont. output power at 25 ºC (W) 1000 1300 1600 2400 4000" in the Victron Inverter 1200VA - 5000VA datasheet, captured on September 25, 2026; the 48/3000 (3000 VA class) column reads "2400" (one value per power class: 1200, 1600, 2000, 3000 and 5000 VA). Recorded in kW as a change of unit of that figure.
Where: Victron Inverter 1200VA - 5000VA datasheet, specification table, "Cont. output power at 25 ºC (W)" row, 48/3000 (3000 VA class) column
The device can be fitted either horizontally or vertically. For optimal cooling, vertical fitting is preferred.
Printed as "The device can be fitted either horizontally or vertically" and "For optimal cooling, vertical fitting is preferred" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 9). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
The neutral output of the inverter is connected to the enclusure, to ensure proper functioning of a GFCI (or RCCB) to be installed in the AC output.
Printed as "The neutral output of the inverter is connected to the enclusure" and "to ensure proper functioning of a GFCI (or RCCB)" in the Victron Energy Inverter 3k 5k 230V manual (firmware xxxx400 or higher) (PDF page 11). The manual covers "48 | 3000 | 230V" and "48 | 5000 | 230V" (PDF page 1).
Where: PDF page 11, 4.3 Connection of the AC cabling
List price of the exact variant with stock keeping unit PIN483020000 as published in the ShopSolar Shopify product feed on 20 September 2026. One unit as listed; shipping, sales tax, permitting and installation are extra. · Store SKU PIN483020000Price readings (32)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PIN483020000. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: 4.2 Connection of battery cables; parallel connection
Retrieved Sep 25, 2026
Victron Energy's own manual for the Phoenix Inverter 12/3000, 24/3000, 48/3000, 24/5000 and 48/5000 230V, hosted on victronenergy.com and captured on September 26, 2026. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs CIN121620000, CIN122200000, CIN241220000, CIN241620000, CIN242200000, CIN122160000, CIN121220000. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Modbus-TCP register listOfficial · Victron Energy · Official product page · Web pageSource details
Revision
Not stated
Revision date
Not stated
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Rows by article number
Retrieved Sep 22, 2026
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CMP122120000, together with 23 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CMP122120000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number CEP122160000, together with 1 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/CEP122160000?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Original manufacturer-hosted PDF preserved byte for byte from the Victron document library, listed by the manufacturer for SKUs PIN123020000, PIN243020000, PIN483020000. The revision is whatever Victron published at this URL on the access date; no later revision or independent verification is claimed.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Declaration of Conformity - Inverter 1200VA – 5000VA
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)
Order: products a manufacturer names first, then by Evidence score at default weights.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Inverter 48/3000
Manufacturer SKU PIN483020000
Observed Sep 18, 2026
EN-IEC 60335-1: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PIN483020000. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.