locator: Victron Energy price list 2026-Q3, page 2, row "Inverter 48/1600 VE.Direct Schuko*" PIN482161200
conditions: Victron Energy's 2026-Q3 price list prints article number PIN482161200 on the row for "Inverter 48/1600 VE.Direct Schuko*" (page 2), this record's product.
Floating ground: the AC output is isolated from the DC input and the chassis; an internal or external neutral to ground connection is needed for a GFCI (or RCCB, RCB or RCD) in the AC output circuit
Printed as "The inverter has a floating ground." and "an internal or external neutral to ground connection needs to be made" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), section 3.2.1 AC output connection. The appendix explains the internal neutral to protective earth wire; neutral is floating by default.
Where: PDF page 7, section 3.2.1 AC output connection
Printed as "8.9 kg" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Weight row, 12/1600 24/1600 48/1600 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source.
Printed as "2100W/15s" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Peak power row, 12/1600 24/1600 48/1600 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source.
Where: PDF page 17, Technical specifications table, Peak power row, 12/1600 24/1600 48/1600 column
Printed as "There should be a clear space of at least 10cm around the appliance for cooling." in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), section 3.1.1 Location.
W 231 × H 117 × D 365 mm / W 9.09 × H 4.61 × D 14.4 in convertedCheck note
Depth differs between two Victron documents. Victron's Inverter VE.Direct 230V Manual (HW15) prints 117x231x365 mm for this model, while Victron's 2026-Q3 price list prints 117 x 231 x 395 mm for its article number.
Printed as "117x231x365" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Dimensions (hxwxd, mm) row, 48/1600 column. Table layout read from rendered page 18. The 1600 column prints 117x231x395 for 12/1600 and 117x231x365 for 24/1600 and 48/1600. Revised on 1 October 2026: The installation manual prints 117x231x365 mm (hxwxd) for the 24/1600 and 48/1600 models; the recorded 395 mm depth is the price list figure, which the manual prints only for the 12/1600 model.
Read from the Victron Energy 2026-Q3 price list, from the row whose article number is PIN482161200. Printed: "117 x 231 x 395". The size column is headed "H x W x D" in millimetres and the weight column "kg". No value was taken from another article number or from a product name.
Printed as "92%" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Max. efficiency row, 48/1600 column. Table layout read from rendered page 18. The row prints one value per model column; this is the last of 18 values. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source.
Printed as "Output AC frequency (adjustable) 50 or 60Hz +/- 0.1%" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Output AC frequency (adjustable) row. The manual states the inverter is set by default at 230Vac 50Hz.
Where: PDF page 17, Technical specifications table, Output AC frequency (adjustable) row
Printed as "Output AC voltage / frequency (adjustable) 230VAC +/ - 3%" in the Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026; the 48/1600 column reads "230VAC +/ - 3%".
Where: Victron Inverter VE.Direct 250W - 1600W 230V datasheet, specification table, "Output AC voltage / frequency (adjustable)" row, 48/1600 column
Printed as "Protection category IP 21" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Protection category row. The installation chapter prints IP21 for base mounting and IP20 for vertical or horizontal wall mounting.
Where: PDF page 18, Technical specifications table, Protection category row
At least half the cross-section of the battery conductors; maximum 25 mm² at the earth lug
Printed as "should have at least half the cross-section of the conductors used for the battery connection" and "The maximum conductor size that fits the earth lug is 25 mm²" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), section 3.2.2 Chassis to ground connection.
Where: PDF page 7, section 3.2.2 Chassis to ground connection
Printed as "Maximum battery cable cross-section" and "25 mm²" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Maximum battery cable cross-section row, 48/1600 column. Table layout read from rendered page 18. This is the largest battery cable cross-section the terminals take, not a recommended size for a given cable length.
Where: PDF page 18, Technical specifications table, Maximum battery cable cross-section row, 48/1600 column
Printed as "15W" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Zero-load power row, 48/1600 column. Table layout read from rendered page 18. The row prints one value per model column. The separate default zero-load power in ECO mode is not recorded here.
Where: PDF page 17, Technical specifications table, Zero-load power row, 48/1600 column
Printed as "1450W" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Continuous power at 25°C row, 12/1600 24/1600 48/1600 column. The figure at 40°C is 1300W. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source.
Where: PDF page 17, Technical specifications table, Continuous power at 25°C row, 12/1600 24/1600 48/1600 column
Base mounting (recommended, IP21), vertical wall mounting with the fan at the bottom (recommended, IP20) or horizontal wall mounting (recommended, IP20); not ceiling mounted or vertical with the fan on top
Printed as "Mount the inverter against a sturdy wall or horizontally on a suitable ground surface." and "2 Base mounting Yes IP21 3 Vertical wall mounting, fan at the bottom. Yes IP20" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), section 3.1.2 Mounting, Mounting directions table. The table continues on PDF page 7: "Vertical mounting, fan on top. No" and "Horizontal wall mounting. Yes IP20".
Where: PDF page 6, section 3.1.2 Mounting, Mounting directions table
Printed as "36.8 -62V" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Input DC voltage range row, 48V models. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Victron Energy (victronenergy.com), which stays listed as an additional source.
Where: PDF page 17, Technical specifications table, Input DC voltage range row, 48V models
Printed as "Operating temperature range -40 to +65°C (fan-assisted cooling)" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Operating temperature range row. Power derating of 1.25% per °C above 40°C is printed beside it.
Where: PDF page 17, Technical specifications table, Operating temperature range row
No reviews. Be the first to review this product: Write a review
Sellers
No listed sellers in this data.
Price history
No seller price history.
Evidence score
6/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Printed as "15W" in Victron Energy's Inverter VE.Direct 230V Manual (HW15, rev 03 - 04/2026), Technical specifications table, Zero-load power row, 48/1600 column. Table layout read from rendered page 18. The row prints one value per model column. The separate default zero-load power in ECO mode is not recorded here.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
ECE R10-4manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "ECE R10-4" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN 55014-1manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN 55014-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN 55014-2manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN 55014-2" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN-IEC 60335-1manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN-IEC 60335-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN-IEC 62109-1manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN-IEC 62109-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
IEC 61000-6-1manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "IEC 61000-6-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
IEC 61000-6-2manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "IEC 61000-6-2" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
IEC 61000-6-3manufacturer claimpresent at observation[3]
Scope
equipment listing
Covered models
PIN482161200
Limitations
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "IEC 61000-6-3" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
Location: Appendix, dimension drawings (one per part number)
Retrieved Sep 28, 2026
Victron Energy's own manual for the Inverter VE.Direct family (HW15 hardware), captured September 28, 2026 from victronenergy.com. Its appendix dimension drawings name each sold part number in full, including PIN121251310 (Inverter 12/250 230V VE.Direct AU/NZ), PIN122121110, PIN122121210, PIN122121310, PIN122121410 (Inverter 12/1200 230V, IEC/SCHUKO/AU-NZ/UK), PIN122161100, PIN122161200, PIN122161300, PIN122161400 (Inverter 12/1600 230V, IEC/SCHUKO/AU-NZ/UK), PIN122161510 (Inverter 12/1600 120V VE.Direct NEMA GFCI, UL 458), PIN241370500 (Inverter 24/375 120V VE.Direct NEMA 5-15R) and PIN482122520 (Inverter 48/1200 120V VE.Direct NEMA 5-15R). It covers installation, operation, monitoring and technical specifications. Its technical-specification tables use a generic article number pattern (for example PINxx2161X00) for the wider product range and do not by themselves name every model; only the part numbers printed in full in the appendix are treated as named here. It does not name the 24V or 48V 1600VA 230V-region variants, the Inverter C (Compact) series, or the 12/2k5 Smart model.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
EN-IEC 60335-1Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN-IEC 60335-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN-IEC 62109-1Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN-IEC 62109-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN 55014-1Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN 55014-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
EN 55014-2Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "EN 55014-2" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
IEC 61000-6-1Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "IEC 61000-6-1" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
IEC 61000-6-2Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "IEC 61000-6-2" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
IEC 61000-6-3Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "IEC 61000-6-3" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
ECE R10-4Manufacturer claim · equipment listingClaimedListed when checked
The Victron Inverter VE.Direct 250W - 1600W 230V datasheet, captured on September 25, 2026, prints "ECE R10-4" in its STANDARDS section, which applies to the model family including the 48/1600 column. This is a manufacturer statement: no issuer listing, certificate number, edition or validity was checked.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Rows by article number
Retrieved Sep 22, 2026
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Victron Energy reference document
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)
Order: products a manufacturer names first, then by Evidence score at default weights.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Inverter 48/1600 VE.Direct Schuko
Manufacturer SKU PIN482161200
No historical observations recorded yet.
Other recorded fields
Field
Value
Conditions
Source
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 40
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: EN-IEC 60335-1 · EN-IEC 62109-1 +6
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.