locator: Victron Energy price list 2026-Q3, page 4, row "Inverter 24/500 VE.Direct NEMA GFCI (UL 458)" PIN245010510
conditions: Victron Energy's 2026-Q3 price list prints article number PIN245010510 on the row for "Inverter 24/500 VE.Direct NEMA GFCI (UL 458)" (page 4), this record's product.
This is a Safety Class I product (supplied with a protective grounding terminal).; The chassis must be grounded.; A grounding point is located on the outside of the product.
Printed as "This is a Safety Class I product (supplied with a protective grounding terminal)" and "The chassis must be grounded" and "A grounding point is located on the outside of the product" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 2).
Where: PDF page 2, 1. Important safety instructions
Printed as "Peak power 400W 700W 900W 1500W 2200W 2200W" in the Victron Inverter VE.Direct 250VA - 1600VA datasheet, captured on September 25, 2026; the 24/500 (500VA class) column reads "900W" (one value per power class).
At least half the cross-section of the conductors used for the battery connection
Printed as "should have at least half the cross-section of the conductors used for the battery connection" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 5).
Where: PDF page 5, 3.3 Wire size for connecting the inverter chassis to ground
Printed as the "Recommended DC cable cross-section" rows, 24/500 column ("6 mm²" and "10 mm²"), in the Inverter VE.Direct 250VA - 1200VA manual, captured on September 26, 2026. Victron's product data lists this manual for SKU PIN245010510.
Where: 3.2 Connection to the battery, 24/500 column
Printed as "Internal DC fuse 3 x 35 A 2 x 25 A 30 A 150 A" and "Fuse type ATOF 32 V ATOF 32 V FKS 80 V BF1 32 V" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 5). The 24/500 column reads "2 x 25 A" and "ATOF 32 V".
Where: PDF page 5, 3.2 Connection to the battery, "Internal DC fuse" and "Fuse type" rows, 24/500 column
Printed as "The VE.Direct port can be connected to" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 3). The port can be connected to a computer (VE.Direct to USB interface cable needed) or to smartphones and tablets (VE.Direct to Bluetooth Smart dongle needed).
Printed as "Input voltage range 9.2 - 17 / 18.4 - 34.0 / 36.8 - 62.0 VDC" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 9). The row lists the 12 Volt, 24 Volt and 48 Volt figures in that order; the 24 Volt figure is recorded.
Where: PDF page 9, 5. Technical data, "Input voltage range" row, 24 Volt figure
Printed as "Cont. power at 25°C / 40°C 200 / 175W 300 / 260W 400 / 350W 650 / 560W 1000 / 850W 1450 / 1200W" in the Victron Inverter VE.Direct 250VA - 1600VA datasheet, captured on September 25, 2026; the 24/500 (500VA class) column reads "400 / 350W" (25 °C figure first, 40 °C second; one value pair per power class). Recorded in kW as a change of unit of that figure.
Base mounting: OK. Vertical wall mounting, fan at bottom: OK. Horizontal wall mounting: OK. Ceiling mounting (inverted): Not recommended. Vertical wall mounting, fan on top: Not recommended.
Printed as "1 Ceiling mounting (inverted). Not recommended 2. Base mounting. OK" and "3 Vertical wall mounting, fan at bottom. OK" and "4 Vertical wall mounting, fan on top. Not recommended" and "5 Horizontal wall mounting. OK" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 4).
Internal DC fuse 2 x 25 A (ATOF 32 V, not replaceable); add a fuse or DC circuit breaker close to the battery if the DC cable is longer than 1.5 m (always for UL NEMA GFCI models)
Printed as "Internal DC fuse 2 x 25 A" and "an additional fuse or DC circuit breaker must be inserted close to the battery." in the Inverter VE.Direct 250VA - 1200VA manual, captured on September 26, 2026. Victron's product data lists this manual for SKU PIN245010510.
Where: 3.2 Connection to the battery, 24/500 column
Units with a GFCI have AC output neutral connected to chassis inside the device by default; a qualified installer should check this connection
Printed as "Units with a GFCI have AC output neutral" and "AC output neutral connected to chassis inside the device by default" and "A qualified installer should check this connection" in the Victron Energy Inverter VE.Direct 250VA - 1200VA manual (PDF page 2). This record is a NEMA GFCI version.
Where: PDF page 2, 1. Important safety instructions
Visit Amazon Paid link. As an Amazon Associate we earn from qualifying purchases.
Price history
No seller price history.
Evidence score
6/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
Victron's public API records "ECE R10-4" in its automotiveDirective field for exact SKU PIN245010510. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PIN245010510. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU PIN245010510. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: 3.2 Connection to the battery
Retrieved Sep 25, 2026
Victron Energy's own manual for the Phoenix Inverter VE.Direct 250VA to 1200VA (12, 24 and 48 V), hosted on victronenergy.com and captured on September 26, 2026; Victron's product data lists it as the product manual for these SKUs. Tables give values per model column; only the exact model's column is read. A manufacturer document, not an independent test.
Archived copies
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Victron Energy's own product API lists this technical information against article number PIN121251100, together with 108 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/PIN121251100?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Location: Document title as published
Retrieved Sep 19, 2026
Victron Energy's own product API lists this technical information against article number PIN121251100, together with 108 further article numbers. Read from https://www.victronenergy.com/api/v1/product/sku/PIN121251100?format=json on 2026-09-19. It establishes that Victron publishes this document for this article number; it does not establish the document's current revision, its scope, or any issuer record behind a certificate.
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.
Location: Rows by article number
Retrieved Sep 22, 2026
Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.
Archived copies
Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Victron Energy reference document
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Declaration of Conformity - Inverter VE.Direct 250VA - 1200VA & Sun Inverters
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Certificate Safety UL 458 - Inverter VE.Direct 250VA - 1600VA
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Its datasheet: Sol-Ark, Schneider Electric, Megarevo, MidNite Solar, Deye, EG4, Victron Energy, Outback Power, SRNE Solar, Magnum Energy (listed as compatible inverters; the manual says the list is not comprehensive or exclusive and does not denote closed-loop communication compatibility)
Order: products a manufacturer names first, then by Evidence score at default weights.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
Inverter 24/500 VE.Direct NEMA GFCI (UL 458)
Manufacturer SKU PIN245010510 · US market
Observed Sep 18, 2026
EN-IEC 60335-1: claimed
Product / system scope unresolved. Victron's public API records "EN-IEC 60335-1" in its safety field for exact SKU PIN245010510. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "EN-IEC 62109-1" in its safety field for exact SKU PIN245010510. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product / system scope unresolved. Victron's public API records "ECE R10-4" in its automotiveDirective field for exact SKU PIN245010510. This is a manufacturer statement: no issuer listing, certificate number, edition, scope or validity was independently checked, and the covered configuration is not established beyond the listed SKU.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.