Trace Engineering SW4048 Sine Wave Inverter/Charger

By Trace EngineeringSKU SW4048

Key specs

Units
SKU
SW4048
Official instruction manual
Sources

Model number as printed by Trace Engineering in the 60 Hz specifications table of its SW Series owner's manual.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), MODEL row

Documented

Weight
48 kg110 lb converted
Official instruction manual
Sources

Printed as "105 lbs (48 kg)" inverter only; shipping weight 111 lbs (50 kg). Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Weight - Inverter Only row

Documented

Output voltage distortion
3 to 5% (stand alone operation)
Official instruction manual
Sources

Printed as "3 to 5% (stand alone operation)" for every model in the table; the output waveform is printed as "Sinewave, 34 to 52 steps per cycle".

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), AC Output Characteristics

Documented

AC voltage
120 vac
Official instruction manual
Sources

Printed as "120 vac" RMS output, voltage regulation ± 2%. Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), AC Output Voltage (RMS) row

Documented

Battery charging
60 A
Official instruction manual
Sources

Printed as "60 amps DC" maximum charging rate, 3 stage regulation. Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Maximum Charging Rate row

Documented

Dimensions
49.82 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 230 × H: 380 × L: 570 mmW: 9.06 × H: 15 × L: 22.4 in convertedOfficial instruction manual
Sources

Converted: 57 cm x 10 = 570 mm; 23 cm x 10 = 230 mm; 38 cm x 10 = 380 mm

Printed as "15” (38 cm) high, 22.5” (57 cm) wide, 9” (23 cm) deep (when wall mounted)" for every model in the table; the centimeter figures are recorded in millimeters, with the 57 cm width as length and the 23 cm depth as width.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Dimensions - Inverter Only row

Calculated

Efficiency
95 %
Official instruction manual
Sources

Peak efficiency, printed as "95%". Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Efficiency (peak) row

Documented

AC frequency
60 Hz
Official instruction manual
Sources

Printed as "60 Hz", frequency regulation ± 0.04% (crystal regulated). Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Nominal Frequency row

Documented

Enclosure
Indoor, ventilated, steel chassis with powdercoat finish
Official instruction manual
Sources

Printed as enclosure type "Indoor, ventilated, steel chassis with powdercoat finish" for every model in the table.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Enclosure Type row

Documented

All specs16
Output voltage distortion
3 to 5% (stand alone operation)
Official instruction manual
Sources

Printed as "3 to 5% (stand alone operation)" for every model in the table; the output waveform is printed as "Sinewave, 34 to 52 steps per cycle".

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), AC Output Characteristics

Documented

AC voltage
120 vac
Official instruction manual
Sources

Printed as "120 vac" RMS output, voltage regulation ± 2%. Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), AC Output Voltage (RMS) row

Documented

Battery charging
60 A
Official instruction manual
Sources

Printed as "60 amps DC" maximum charging rate, 3 stage regulation. Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Maximum Charging Rate row

Documented

Efficiency
95 %
Official instruction manual
Sources

Peak efficiency, printed as "95%". Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Efficiency (peak) row

Documented

AC frequency
60 Hz
Official instruction manual
Sources

Printed as "60 Hz", frequency regulation ± 0.04% (crystal regulated). Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Nominal Frequency row

Documented

Battery voltage
48 V DC
Official instruction manual
Sources

Printed as "48 vdc". Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Nominal DC Input Voltage row

Documented

Grid pass-through
60 A
Official instruction manual
Sources

Printed as "60 amps AC" automatic transfer relay. Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Automatic Transfer Relay row

Documented

Idle consumption
16 W
Official instruction manual
Sources

Printed as "0.33 A (16 W)" in On Mode with no load; search mode draws "0.025 A (1 W)". Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), DC Input Requirements, On Mode (no load - idle) row

Documented

Continuous AC current
33 A
Official instruction manual
Sources

Printed as "33 amps AC" continuous output at 25 °C; maximum output is 78 amps AC (RMS). Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), Continuous Output (@ 25 °C) row

Documented

Battery operating voltage
44 to 66 V
Official instruction manual
Sources

Printed as "44 to 66 vdc". Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), DC Input Requirements, Input Voltage Range row

Documented

Continuous apparent output power
4 kVA
Converted: 4000 VA / 1000 VA per kVA = 4 kVA
Official instruction manual
Sources

Converted: 4000 VA / 1000 VA per kVA = 4 kVA

Printed as "4000 VA" continuous power at 20 °C, recorded in kVA; the manual prints this rating in volt-amperes only, so no continuous power in watts is recorded. Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Specifications and Features (60 Hz Models), page 118, Continuous Power @ 20 °C row

Converted

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.comOfficialTrace Engineering Company, Inc.Official instruction manual
    Certificate & compliance claims (2)
    UL 1741Manufacturer claim · equipment listingClaimedListed when checked

    The 1999 owner's manual says the 120 VAC/60 Hertz models of the SW Series are ETL listed to UL Standard 1741 (Draft), Static Inverters and Charge Controllers for use in Photovoltaic Systems. No certificate or file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.

    Manufacturer document

    Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document
    CSA C22.2 No. 107.1Manufacturer claim · equipment listingClaimedListed when checked

    The 1999 owner's manual says the 120 VAC/60 Hertz models of the SW Series are also ETL listed to Canadian Standard CSA - C 22.2 No. 107.1 - M1, Commercial and Industrial Power Supplies. No certificate or file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.

    Manufacturer document

    Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-04.

    Location: Specifications and Features (60 Hz Models), page 118; Introduction, listings

    Retrieved

    Trace Engineering's own owner's manual for the SW Series, linked as the SW Series owner's guide in the discontinued products section of Xantrex's xantrex.com library. Its 60 Hz specifications table has a column for the SW4048.

    Archived copies

    Archived copy of a document published by Trace Engineering Company, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 2.75 MB

    Archived copy, unaltered, kept as a record of what Trace Engineering Company, Inc. published. Original address: https://xantrex.com/wp-content/uploads/2023/03/SW2512MC_sw4024mc_OG.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    152
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 8c70ef8b0ef19b29d22186ce53585fb040804a45e6f8b72477d3086cb63f447a

    Open
  • WEB
    Xantrex library, Discontinued Products, SW Series owner's guide page, captured October 4, 2026OfficialTrace Engineering Company, Inc.Official product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-04.

    Location: Discontinued Products, SW Series, owner's guide link

    Retrieved

    Used only to show that Xantrex's own library links the Trace Engineering SW Series owner's manual; no figure is cited to this page.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com

Archived copy of a document published by Trace Engineering Company, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 2.75 MB

Archived copy, unaltered, kept as a record of what Trace Engineering Company, Inc. published. Original address: https://xantrex.com/wp-content/uploads/2023/03/SW2512MC_sw4024mc_OG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
152
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8c70ef8b0ef19b29d22186ce53585fb040804a45e6f8b72477d3086cb63f447a

Submit a document

Warranty

Product warranty
2 years
Official instruction manual
Sources

Printed as "Trace Engineering warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase", extended to all purchasers or owners during the warranty period. The warranty given then by a company that no longer trades under that name.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Location: Warranty/Repair Information, Limited Warranty

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

13/100Missing details85% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term2 years2.4 / 30.0

2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Trace Engineering warrants its power products against defects in materials and workmanship for a period of two (2) years from the date of purchase", extended to all purchasers or owners during the warranty period. The warranty given then by a company that no longer trades under that name.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document
Idle consumption16 W0.0 / 10.0

16 against 0.021 W, the lowest documented for an inverter (printed by the maker): Enphase IQ8M Microinverter IQ8M-72-2-US

Printed as "0.33 A (16 W)" in On Mode with no load; search mode draws "0.025 A (1 W)". Read from the SW4048 column (the third model column) of the 60 Hz specifications table in Trace Engineering's SW Series owner's manual (Part No. 2031-5, Rev. B, September 1, 1999, revision 4.01 software). The SW4048K and SW4048J are separate 105 VAC models in the same manual and are not this record.

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Research pending, 0 points: Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5

How it works

Certificates

2 on fileUL 1741 · claimed
UL 1741Product / system scope unresolvedClaimedListed when checked

The 1999 owner's manual says the 120 VAC/60 Hertz models of the SW Series are ETL listed to UL Standard 1741 (Draft), Static Inverters and Charge Controllers for use in Photovoltaic Systems. No certificate or file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.

Models: SW4048

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document
CSA C22.2 No. 107.1Product / system scope unresolvedClaimedListed when checked

The 1999 owner's manual says the 120 VAC/60 Hertz models of the SW Series are also ETL listed to Canadian Standard CSA - C 22.2 No. 107.1 - M1, Commercial and Industrial Power Supplies. No certificate or file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.

Models: SW4048

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document
Datasheet & manual claims2
UL 1741Manufacturer claim · equipment listingClaimedListed when checked

The 1999 owner's manual says the 120 VAC/60 Hertz models of the SW Series are ETL listed to UL Standard 1741 (Draft), Static Inverters and Charge Controllers for use in Photovoltaic Systems. No certificate or file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.

Manufacturer document

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document
CSA C22.2 No. 107.1Manufacturer claim · equipment listingClaimedListed when checked

The 1999 owner's manual says the 120 VAC/60 Hertz models of the SW Series are also ETL listed to Canadian Standard CSA - C 22.2 No. 107.1 - M1, Commercial and Industrial Power Supplies. No certificate or file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.

Manufacturer document

Official instruction manual: Trace Engineering SW Series Inverter/Chargers With Revision 4.01 Software, Owner's Manual (Part No. 2031-5, Rev. B, September 1, 1999), as hosted by Xantrex on xantrex.com Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SW4048

Manufacturer SKU SW4048

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.