Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Sungrow's image for the SG36/60CX-US, shown on the SG60CX-US page; not a photo specific to this exact modelThree-phase inverter
Sungrow SG60CX-US
Key specs
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 65 kg / 140 lb converted | Printed as 65 kg (143.3 lbs). Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, General Data | [1] |
| MPPT count | 6 | Number of independent MPP inputs. Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, Input (DC) | [1] |
| AC voltage | 480 | Nominal AC voltage 277 / 480 V; the printed AC voltage range is 422-528 V. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Output (AC) | [1] |
| Frequency | 60 Hz | Nominal grid frequency; the printed range is 55-65 Hz. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Output (AC) | [1] |
| Dimensions | W 782 × H 645 × D 310 mm / W 30.8 × H 25.4 × D 12.2 in converted | Inverter only, width x height x depth 782 x 645 x 310 mm (30.7" * 25.4" * 12.2"); the wire-box is printed separately as 231 x 295 x 234 mm. Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, General Data | [1] |
| Communications | RS485; SunSpec Modbus third-party protocol | The user manual prints RS485 and SunSpec Modbus; the datasheet prints "RS485 / optional: WiFi and Ethernet". A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, General Data | [1] |
| Efficiency | 98.8 % | Maximum efficiency. Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, Efficiency | [1] |
| MPPT voltage | 200 to 1,000 V | MPP voltage range; the MPP voltage range for rated power is printed as 550-850 V. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Input (DC) | [1] |
| AC configuration | Three-phase, 277/480 V AC | Printed as "3 / N / PE, 277 / 480 V" with feed-in phases / connection phases 3/3. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Output (AC) | [1] |
| Enclosure rating | Type 4X (NEMA 4X, IP66) | Degree of protection. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, General Data | [1] |
| Max PV current | 26 A x 6 | Maximum PV input current, printed as 26A*6 (26 A per MPPT); maximum DC short-circuit current is printed as 45 A per MPPT. Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, Input (DC) | [1] |
| Max PV voltage | 1,000 V | Maximum PV input voltage. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Input (DC) | [1] |
| Apparent power | 60,000 VA | AC output power 60 kVA at 113 °F (45 °C) ambient; 50 kVA at 122 °F (50 °C). Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, Output (AC), AC output power | [1] |
| PV start voltage | 250 V | Start-up input voltage; the minimum PV input voltage is printed as 200 V. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Input (DC) | [1] |
| PV strings per MPPT | 2 | Maximum number of PV strings per MPPT. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Input (DC) | [1] |
| Operating temperature | -30 to 60 °C / -22 to 140 °F converted | Operating ambient temperature range; derating above 45 °C. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, General Data | [1] |
| Weighted efficiency | 98 % | CEC efficiency. Read from the SG60CX-US column (the second of two model columns; the other is SG36CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted. Where: User manual section 9.1, Efficiency | [1] |
| AC voltage configuration | 3 / N / PE, 277 / 480 V V | Literal nominal AC voltage and connection printed by Sungrow. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual. Where: User manual section 9.1, Output (AC) | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- AC output (VA)
- 60,000 VA
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers 6MPPT range 200 to 1000 V
- AC output
- Three-phase, 277/480 V AC
- Warranty
- Not stated
- Size
- 156.36 L* (Calculated from published dimensions)W: 782 × H: 645 × D: 310 mm / W: 30.8 × H: 25.4 × D: 12.2 inWeight 65 kg / 140 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
How it worksCertificates
UL1741manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "UL1741" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
UL 1741 SA/SBmanufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "UL 1741 SA/SB" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
CA Rule 21manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "CA Rule 21" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
IEEE 1547manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "IEEE 1547" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
IEEE 1547.1manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "IEEE 1547.1" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
CSA C22.2, No.107.1-01manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "CSA C22.2, No.107.1-01" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
UL 1699Bmanufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "UL 1699B" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
FCC Part 15manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "FCC Part 15" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
UL1998manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "UL1998" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
Rule 14manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "Rule 14" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
NEC 2023manufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "NEC 2023" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
Sunspec Rapid Shutdownmanufacturer claimpresent at observation[1] [3]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- The Sungrow SG36/60CX-US user manual lists "Sunspec Rapid Shutdown" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1] [3]
UL 1741 SAauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG60CX-US {480V}": UL 1741 SA, certifying entity CSA Group, certificate date 2020-09-30, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Sep 30, 2020Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
UL 1741 SBauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG60CX-US {480V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-10-14, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Oct 14, 2022Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
CECauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- SG60CX-US
- Limitations
- Model SG60CX-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Sungrow, as "SG60CX-US {480V}", CEC listing date 2020-12-21. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Dec 21, 2020Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)Open
Certificate & compliance claims (12)
UL1741Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL1741" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)UL 1741 SA/SBManufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL 1741 SA/SB" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)CA Rule 21Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "CA Rule 21" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "IEEE 1547" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "IEEE 1547.1" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)CSA C22.2, No.107.1-01Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "CSA C22.2, No.107.1-01" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)UL 1699BManufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL 1699B" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)FCC Part 15Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "FCC Part 15" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)UL1998Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL1998" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)Rule 14Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "Rule 14" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)NEC 2023Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "NEC 2023" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)Sunspec Rapid ShutdownManufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "Sunspec Rapid Shutdown" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Section 9.1, Technical Data
Retrieved Sep 23, 2026
Sungrow user manual for the SG36CX-US and SG60CX-US, linked from Sungrow's US product page and archived on September 24, 2026. The Technical Data table in section 9.1 sets the two models side by side, so every per-model figure is read from the named column and the whole row is quoted. Its Compliance row is a manufacturer claim that no issuer record was read against.
Archived copies
Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupSG36_60CX_US-UEN-Ver17-202411 · 17.44 MBArchived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/11/29/M-D-000059-JS-105303-SG36_60CX_US-UEN-Ver17-202411_compress.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 16be211a8db4d8739b884b5a0fcd94c93f40065dc0b584917a4e9f4de7c4387c
Datasheets
- Sungrow datasheet: SG36/60CX-US (Version 14)Open
Certificate & compliance claims (12)
UL1741Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL1741" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)UL 1741 SA/SBManufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL 1741 SA/SB" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)CA Rule 21Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "CA Rule 21" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "IEEE 1547" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "IEEE 1547.1" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)CSA C22.2, No.107.1-01Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "CSA C22.2, No.107.1-01" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)UL 1699BManufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL 1699B" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)FCC Part 15Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "FCC Part 15" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)UL1998Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "UL1998" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)Rule 14Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "Rule 14" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)NEC 2023Manufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "NEC 2023" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)Sunspec Rapid ShutdownManufacturer claim · equipment listingClaimedListed when checked
The Sungrow SG36/60CX-US user manual lists "Sunspec Rapid Shutdown" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG60CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page 2, Compliance row
Retrieved Sep 23, 2026
Two-page Sungrow datasheet for the SG36CX-US and SG60CX-US, linked from Sungrow's US product page and archived on September 24, 2026. Its table text does not extract in model-column order, so no per-model figure is read from it; it is cited for the model names and the compliance list, which is a manufacturer claim that no issuer record was read against.
Archived copies
Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupVersion 14 · 0.27 MBArchived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/09/14/DS_20240619_SG36_60CX-US_Datasheet_V14_EN.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 947b58ee97a5701f118aa122f2535cf86054193053f52533bdb4092b3e51a0e8
Other documents
- Sungrow SG36/60CX-US | Sungrow US product page (September 24, 2026 capture)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page body; Download Datasheet and User Manual links
Retrieved Sep 23, 2026
Sungrow US product page for the SG36/60CX-US, captured on September 24, 2026. It prints summary figures for the family (the 60 kVA, 98.8 % figures are the SG60CX-US values) and links the datasheet and user manual; per-model figures are read from the user manual.
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/11/29/M-D-000059-JS-105303-SG36_60CX_US-UEN-Ver17-202411_compress.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 16be211a8db4d8739b884b5a0fcd94c93f40065dc0b584917a4e9f4de7c4387c
Sungrow datasheet: SG36/60CX-US (Version 14)
Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/09/14/DS_20240619_SG36_60CX-US_Datasheet_V14_EN.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 947b58ee97a5701f118aa122f2535cf86054193053f52533bdb4092b3e51a0e8
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- SG60CX-US
Manufacturer SKU SG60CX-US · US market
Observed Oct 11, 2026
UL 1741 SA: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG60CX-US {480V}": UL 1741 SA, certifying entity CSA Group, certificate date 2020-09-30, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG60CX-US {480V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-10-14, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model SG60CX-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Sungrow, as "SG60CX-US {480V}", CEC listing date 2020-12-21. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 45 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB · UL1741 +12 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [2] key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411) (Sungrow Power Supply Co., Ltd. · manufacturer · SG36 60CX US-UEN-Ver17-202411 · observed Sep 23, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
- Sungrow datasheet: SG36/60CX-US (Version 14) (Sungrow Power Supply Co., Ltd. · manufacturer · Version 14 · observed Sep 23, 2026)
Sign in to report an error on this page
Similar products
All with a priceNEP NEPTUNE NEP-30KW 30 kW three-phase string inverter
Sol-Ark 30K-3P-208V
Sol-Ark 60K-3P-480V
Solis S5-GC60K-LV-US
* Missing details