Charged ReviewsSaved 0Compare 0Login
Sungrow SG36CX-US
Sungrow
Three-phase inverter

Sungrow SG36CX-US

Key specs

Weight54 kg / 120 lb converted
Max PV voltage1,000 V
Efficiency98.6 %
Weighted efficiency98 %
PV start voltage250 V
MPPT count4

All specifications

Identity

BrandSungrow · Website
ModelSG36CX-US
MarketUS
Manufacturer SKUSG36CX-US
About brandSungrow makes PV inverters and energy storage systems. Its brand story page lists 1997 as the establishment of the company and 2011 as its listing on the Shenzhen Stock Exchange; its documents name Sungrow Power Supply Co., Ltd.
SKU detail
locator: User manual section 9.1, Technical Data, column heading
conditions: Model printed as a column heading of the Technical Data table in the Sungrow SG36/60CX-US user manual and on the datasheet. Greentech Renewables lists part number SG36CX with the title "SunGrow 36kW 3 Phase String Inverter, SG36CX-US".
Sources: [1]
FieldValueConditionsSource
Weight54 kg / 120 lb converted
Printed as 54 kg (119.0 lbs). Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, General Data
[1]
MPPT count4
Number of independent MPP inputs. Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, Input (DC)
[1]
AC voltage480
Nominal AC voltage 277 / 480 V; the printed AC voltage range is 422-528 V. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Output (AC)
[1]
Frequency60 Hz
Nominal grid frequency; the printed range is 55-65 Hz. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Output (AC)
[1]
DimensionsW 702 × H 595 × D 310 mm / W 27.6 × H 23.4 × D 12.2 in converted
Inverter only, width x height x depth 702 x 595 x 310 mm (27.6" * 23.4" * 12.2"); the wire-box is printed separately as 231 x 295 x 234 mm. Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, General Data
[1]
CommunicationsRS485; SunSpec Modbus third-party protocol
The user manual prints RS485 and SunSpec Modbus; the datasheet prints "RS485 / optional: WiFi and Ethernet". A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, General Data
[1]
Efficiency98.6 %
Maximum efficiency. Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, Efficiency
[1]
MPPT voltage200 to 1,000 V
MPP voltage range; the MPP voltage range for rated power is printed as 550-850 V. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Input (DC)
[1]
AC configurationThree-phase, 277/480 V AC
Printed as "3 / N / PE, 277 / 480 V" with feed-in phases / connection phases 3/3. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Output (AC)
[1]
Enclosure ratingType 4X (NEMA 4X, IP66)
Degree of protection. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, General Data
[1]
Max PV current26 A x 4
Maximum PV input current, printed as 26A*4 (26 A per MPPT); maximum DC short-circuit current is printed as 45 A per MPPT. Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, Input (DC)
[1]
Max PV voltage1,000 V
Maximum PV input voltage. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Input (DC)
[1]
Apparent power36,000 VA
AC output power 36 kVA at 113 °F (45 °C) ambient; 30 kVA at 122 °F (50 °C). Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, Output (AC), AC output power
[1]
PV start voltage250 V
Start-up input voltage; the minimum PV input voltage is printed as 200 V. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Input (DC)
[1]
PV strings per MPPT2
Maximum number of PV strings per MPPT. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Input (DC)
[1]
Operating temperature-30 to 60 °C / -22 to 140 °F converted
Operating ambient temperature range; derating above 45 °C. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, General Data
[1]
Weighted efficiency98 %
CEC efficiency. Read from the SG36CX-US column (the first of two model columns; the other is SG60CX-US) of the Technical Data table in section 9.1 of the SG36/60CX-US user manual; the whole row is quoted.
Where: User manual section 9.1, Efficiency
[1]
AC voltage configuration3 / N / PE, 277 / 480 V V
Literal nominal AC voltage and connection printed by Sungrow. A single value is printed across both model columns of the Technical Data table in section 9.1 of the SG36/60CX-US user manual.
Where: User manual section 9.1, Output (AC)
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

AC output (VA)
36,000 VA
Battery voltage
Not stated
Solar input
Not statedMPPT trackers 4MPPT range 200 to 1000 V
AC output
Three-phase, 277/480 V AC
Warranty
Not stated
Size
129.48 L* (Calculated from published dimensions)W: 702 × H: 595 × D: 310 mm / W: 27.6 × H: 23.4 × D: 12.2 inWeight 54 kg / 120 lb

Evidence score

14/100Missing details45% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 SB · UL1741 +12Claimed14.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[2]

Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
UL1741manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "UL1741" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
UL 1741 SA/SBmanufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "UL 1741 SA/SB" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
CA Rule 21manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "CA Rule 21" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
IEEE 1547manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "IEEE 1547" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
IEEE 1547.1manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "IEEE 1547.1" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
CSA C22.2, No.107.1-01manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "CSA C22.2, No.107.1-01" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
UL 1699Bmanufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "UL 1699B" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
FCC Part 15manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "FCC Part 15" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
UL1998manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "UL1998" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
Rule 14manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "Rule 14" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
NEC 2023manufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "NEC 2023" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
Sunspec Rapid Shutdownmanufacturer claimpresent at observation[1] [3]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
The Sungrow SG36/60CX-US user manual lists "Sunspec Rapid Shutdown" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1] [3]
UL 1741 SAauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG36CX-US {480V}": UL 1741 SA, certifying entity CSA Group, certificate date 2020-09-30, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Sep 30, 2020
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[2]
UL 1741 SBauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG36CX-US {480V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-10-14, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: Oct 14, 2022
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[2]
CECauthority listing reportedlisted as of snapshot[2]
Scope
equipment listing
Covered models
SG36CX-US
Limitations
Model SG36CX-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Sungrow, as "SG36CX-US {480V}", CEC listing date 2020-12-21. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Dec 21, 2020
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[2]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)Official · Sungrow Power Supply Co., Ltd. · Official user manual · PDF
    Certificate & compliance claims (12)
    UL1741Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL1741" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    UL 1741 SA/SBManufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL 1741 SA/SB" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    CA Rule 21Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "CA Rule 21" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "IEEE 1547" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "IEEE 1547.1" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    CSA C22.2, No.107.1-01Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "CSA C22.2, No.107.1-01" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    UL 1699BManufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL 1699B" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    FCC Part 15Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "FCC Part 15" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    UL1998Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL1998" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    Rule 14Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "Rule 14" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    NEC 2023Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "NEC 2023" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    Sunspec Rapid ShutdownManufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "Sunspec Rapid Shutdown" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official user manual: Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)
    Source details
    Revision
    SG36_60CX_US-UEN-Ver17-202411
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Section 9.1, Technical Data

    Retrieved Sep 23, 2026

    Sungrow user manual for the SG36CX-US and SG60CX-US, linked from Sungrow's US product page and archived on September 24, 2026. The Technical Data table in section 9.1 sets the two models side by side, so every per-model figure is read from the named column and the whole row is quoted. Its Compliance row is a manufacturer claim that no issuer record was read against.

    Archived copies

    Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupSG36_60CX_US-UEN-Ver17-202411 · 17.44 MB

    Archived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/11/29/M-D-000059-JS-105303-SG36_60CX_US-UEN-Ver17-202411_compress.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    89

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 16be211a8db4d8739b884b5a0fcd94c93f40065dc0b584917a4e9f4de7c4387c

    Open
  • Datasheets

  • Sungrow datasheet: SG36/60CX-US (Version 14)Official · Sungrow Power Supply Co., Ltd. · Official datasheet · PDF
    Certificate & compliance claims (12)
    UL1741Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL1741" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    UL 1741 SA/SBManufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL 1741 SA/SB" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    CA Rule 21Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "CA Rule 21" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "IEEE 1547" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    IEEE 1547.1Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "IEEE 1547.1" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    CSA C22.2, No.107.1-01Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "CSA C22.2, No.107.1-01" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    UL 1699BManufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL 1699B" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    FCC Part 15Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "FCC Part 15" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    UL1998Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "UL1998" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    Rule 14Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "Rule 14" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    NEC 2023Manufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "NEC 2023" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    Sunspec Rapid ShutdownManufacturer claim · equipment listingClaimedListed when checked

    The Sungrow SG36/60CX-US user manual lists "Sunspec Rapid Shutdown" in its Compliance row ("UL1741, UL 1741 SA/SB, CA Rule 21, IEEE 1547, IEEE 1547.1, CSA C22.2, No.107.1-01, UL 1699B and FCC Part 15, UL1998, Rule 14, NEC 2023, Sunspec Rapid Shutdown"), one value for both models, and the datasheet prints the same list, writing "UL1741 SA/SB" without the space.This is recorded as the manufacturer's claim exactly as printed, for SG36CX-US. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.

    Manufacturer document

    Official datasheet: Sungrow datasheet: SG36/60CX-US (Version 14)
    Source details
    Revision
    Version 14
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Page 2, Compliance row

    Retrieved Sep 23, 2026

    Two-page Sungrow datasheet for the SG36CX-US and SG60CX-US, linked from Sungrow's US product page and archived on September 24, 2026. Its table text does not extract in model-column order, so no per-model figure is read from it; it is cited for the model names and the compliance list, which is a manufacturer claim that no issuer record was read against.

    Archived copies

    Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupVersion 14 · 0.27 MB

    Archived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/09/14/DS_20240619_SG36_60CX-US_Datasheet_V14_EN.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 947b58ee97a5701f118aa122f2535cf86054193053f52533bdb4092b3e51a0e8

    Open
  • Other documents

  • Sungrow SG36/60CX-US | Sungrow US product page (September 24, 2026 capture)Official · Sungrow Power Supply Co., Ltd. · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Page body; Download Datasheet and User Manual links

    Retrieved Sep 23, 2026

    Sungrow US product page for the SG36/60CX-US, captured on September 24, 2026. It prints summary figures for the family (the 60 kVA, 98.8 % figures are the SG60CX-US values) and links the datasheet and user manual; per-model figures are read from the user manual.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411)

Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupSG36_60CX_US-UEN-Ver17-202411 · 17.44 MB

Archived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/11/29/M-D-000059-JS-105303-SG36_60CX_US-UEN-Ver17-202411_compress.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
89

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 16be211a8db4d8739b884b5a0fcd94c93f40065dc0b584917a4e9f4de7c4387c

Sungrow datasheet: SG36/60CX-US (Version 14)

Archived copy of a document published by Sungrow Power Supply Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupVersion 14 · 0.27 MB

Archived copy, unaltered, kept as a record of what Sungrow Power Supply Co., Ltd. published. Original address: https://info-support.sungrowpower.com/application/pdf/2024/09/14/DS_20240619_SG36_60CX-US_Datasheet_V14_EN.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 947b58ee97a5701f118aa122f2535cf86054193053f52533bdb4092b3e51a0e8

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SG36CX-US

Manufacturer SKU SG36CX-US · US market

  1. Observed Oct 11, 2026

    UL 1741 SA: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG36CX-US {480V}": UL 1741 SA, certifying entity CSA Group, certificate date 2020-09-30, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.

    [2]

  2. Observed Oct 11, 2026

    UL 1741 SB: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Sungrow "SG36CX-US {480V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-10-14, CEC listing date 2020-12-21. A state equipment list entry, not the certification body's own record.

    [2]

  3. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model SG36CX-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Sungrow, as "SG36CX-US {480V}", CEC listing date 2020-12-21. This is an equipment listing, not UL certification or complete-system approval.

    [2]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 45
basis: Unknown
missing:
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 31.5
unit: Unknown
shown: UL 1741 SB · UL1741 +12
shown detail: Claimed
state: claimed
points: 14.2
ceiling: 45
weight: 45
share: 31.5
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [2]
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Sungrow user manual: SG36CX-US / SG60CX-US PV Grid-Connected Inverter (SG36_60CX_US-UEN-Ver17-202411) (Sungrow Power Supply Co., Ltd. · manufacturer · SG36 60CX US-UEN-Ver17-202411 · observed Sep 23, 2026)
  2. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
  3. Sungrow datasheet: SG36/60CX-US (Version 14) (Sungrow Power Supply Co., Ltd. · manufacturer · Version 14 · observed Sep 23, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details