SunGoldPower's own product data, captured 2026-10-27, prints SKU "SPH504880A" for option "SPH504880A [80A MPPT] / Only Inverter" (variant 44404161511561) of listing "5000W 48V Solar Charger Inverter".
Printed as "The ground wire is connected to the ground screw hold through Oshaped terminal." (PDF page 11, spelled so) and, for setting item 63 "Auto N-PE connection switch function", "DIS (default) Disable auto N-PE connection switch" (PDF page 27) in the SPH504880A "Solar charger inverter" user manual Ver. V2.0.
Printed as "Peak power 10000VA" in the single-model table (Model SPH504880A) of the SPH504880A "Solar charger inverter" user manual Ver. V2.0. No duration is printed with it. Revised on 1 October 2026: The manual prints the peak power as "10000VA"; the recorded text "10,000 VA" is the same figure in a different form, so the fact now carries the printed form. The manual cover prints "Ver.: V2.0".
10,000 VA
Printed as "Peak power 10000VA" in the SPH504880A user manual V1.0. No duration is printed. Captured on September 25, 2026.
Printed as "SPH504880A 30mm2/2AWG 125A 80A 2P—160A" in the battery table (columns: recommended wire diameter, rated battery discharge current, maximum charge current, recommended breaker) of the SPH504880A "Solar charger inverter" user manual Ver. V2.0; setting item 07 "Maximum charge current" is printed as "[07] 60A default setting range 0~80A." (PDF page 21). Settable; 80 A is the maximum.
Printed as "Peak power 10000VA" in the single-model table (Model SPH504880A) of the SPH504880A "Solar charger inverter" user manual Ver. V2.0. No duration is printed with it. Revised on 1 October 2026: The manual prints the peak power as "10000VA"; the recorded text "10,000 VA" is the same figure in a different form, so the fact now carries the printed form. The manual cover prints "Ver.: V2.0".
10,000 VA
Printed as "Peak power 10000VA" in the SPH504880A user manual V1.0. No duration is printed. Captured on September 25, 2026.
Printed as "SPH504880A 30mm2/2AWG 125A 80A 2P—160A" in the battery table (columns: recommended wire diameter, rated battery discharge current, maximum charge current, recommended breaker) of the SPH504880A "Solar charger inverter" user manual Ver. V2.0; setting item 07 "Maximum charge current" is printed as "[07] 60A default setting range 0~80A." (PDF page 21). Settable; 80 A is the maximum.
Printed as "The all-in-one solar charge inverter is off-grid." in the safety instructions of the SPH504880A "Solar charger inverter" user manual Ver. V2.0.
Printed as "Battery type Lead acid or lithium battery" in the SPH504880A "Solar charger inverter" user manual Ver. V2.0. Setting item 33 (PDF page 27) lists the lithium battery BMS protocols for the RS485 port.
Location: User manual V1.0 (SPH504880A_V1.0_20250611.pdf), section 8 Technical Parameter, Solar charge, Charge current range of solar energy (settable) row
Printed as "The ground wire is connected to the ground screw hold through Oshaped terminal." (PDF page 11, spelled so) and, for setting item 63 "Auto N-PE connection switch function", "DIS (default) Disable auto N-PE connection switch" (PDF page 27) in the SPH504880A "Solar charger inverter" user manual Ver. V2.0.
Printed as "SPH504880A 6mm2/10AWG 22A 2P—25A" in the PV input table of the SPH504880A "Solar charger inverter" user manual Ver. V2.0. A reference size only.
Read from rendered page 10: the installation schematic labels 500mm above and below the unit and 200mm to the left and right. The step text (PDF page 9) is printed as "At least reserve 200mm space at the left and right air outlets". From the SPH504880A "Solar charger inverter" user manual Ver. V2.0.
Printed as "SPH504880A 10mm²/7AWG 63A 2P—63A" in the AC input table of the SPH504880A "Solar charger inverter" user manual Ver. V2.0, with the note "there is already a corresponding breaker at input connection point of mains supply. There fore, no breaker may be equipped."
Printed as "SPH504880A 30mm2/2AWG 125A 80A 2P—160A" in the battery table of the SPH504880A "Solar charger inverter" user manual Ver. V2.0 (rated battery discharge current 125A, maximum charge current 80A). A reference size only.
Printed as "Mains or generator: Connected at the AC input, it can supply power to the load and charge the battery at the same time." (PDF page 5) and "This dry node can control the switch of diesel generator to charge the battery." (PDF page 29) in the SPH504880A "Solar charger inverter" user manual Ver. V2.0.
Printed as "SPH504880A 10mm²/7AWG 63A 2P—63A" in the AC input table of the SPH504880A "Solar charger inverter" user manual Ver. V2.0 (maximum bypass input current 63A). A reference size only.
Printed as "SPH504880A 30mm2/2AWG 125A 80A 2P—160A" in the battery table of the SPH504880A "Solar charger inverter" user manual Ver. V2.0; the wiring warning (PDF page 13) says "a breaker must be installed at the battery end".
Printed as "SPH504880A 10mm²/7AWG 42A 63A 2P—63A" in the AC output table of the SPH504880A "Solar charger inverter" user manual Ver. V2.0 (rated inverter AC output current 42A, maximum bypass output current 63A). A reference size only.
Printed as "⑥ RS485 communication port", "USB communication port", "⑧ WIFI communication port" and "⑨ Dry contact port" in the product characteristics legend of the SPH504880A "Solar charger inverter" user manual Ver. V2.0. Section 5.2 (PDF page 29) says the WIFI port takes the optional RS485 to WiFi/GPRS module and the RS485 port talks to a lithium battery BMS.
Published claims and calculations, not independent test results.
Documents
2 on file
PDF
5000W 48V Solar Charger Inverter SPH504880A User ManualOfficialSunGoldPowerOfficial instruction manual
Certificate & compliance claims (4)
CE(IEC62109-1)Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
FCCManufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
SAAManufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
EN61000Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
SunGoldPower publishes this instruction manual for SPH5048P, among other models named on the same document. Read from https://sungoldpower.com/collections/power-inverter on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Location: Document title as published
Retrieved
SunGoldPower publishes this instruction manual for SPH5048P, among other models named on the same document. Read from https://sungoldpower.com/collections/power-inverter on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Location: Product heading; Highlight list; Specification and User Manual tabs (manual-download-button links)
Retrieved
SunGoldPower's own product page, captured byte for byte on September 23, 2026. It establishes what SunGoldPower published for SPH5048P, SPH504880A on that date: the page heading, the Highlight text, the variant selector (SKUs SPH5048P, SPH5048P+SG48100P, SPH504880A, SPH504880A+SG48100P) and the 5 document link(s) under its User Manual tab. Prices and stock on the page are the state of a promotional storefront and are not recorded from it. A specification quoted from the page is SunGoldPower's own published figure, not a test result.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
5000W 48V Solar Charger Inverter SPH504880A User Manual
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
UL 1741:2021 Ed.3+R:19May2023Product / system scope unresolvedClaimedListed when checked
Intertek certificate of compliance for report 2510B1701SHA-001, issued January 16, 2026, model SPH504880A only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.
CSA C22.2#107.1:2016 Ed.4+U1Product / system scope unresolvedClaimedListed when checked
Intertek certificate of compliance for report 2510B1701SHA-001, issued January 16, 2026, model SPH504880A only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.
CE(IEC62109-1)Product / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
FCCProduct / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
SAAProduct / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
EN61000Product / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
CE(IEC62109-1)Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
FCCManufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
SAAManufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
EN61000Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/SAA EMC authentication grade EN61000" (SPH504880A_V1.0_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SPH504880A
Manufacturer SKU SPH504880A
Observed
UL 1741:2021 Ed.3+R:19May2023: claimed
Product / system scope unresolved. Intertek certificate of compliance for report 2510B1701SHA-001, issued January 16, 2026, model SPH504880A only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.
Product / system scope unresolved. Intertek certificate of compliance for report 2510B1701SHA-001, issued January 16, 2026, model SPH504880A only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.