Charged Reviews · Quick reference
SunGoldPower SPH504880A
- Brand
- SunGoldPower
- Model
- SPH504880A
- SKU / part number
- SPH504880A[5]
- Category
- Inverters

AC output
| Continuous output | 5 kW[3] |
|---|---|
| Peak output | 10000VA[3] |
| AC configuration | ? |
| AC output voltage | 120Vac (100/105/110Vac Settable)[3] |
| AC frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz[3] |
| Grid pass-through | 63 A[3] |
| Maximum output per leg | ? |
Battery
| Battery voltage | 48 V[3] |
|---|---|
| Battery voltage range | 40 to 60 V[3] |
| Maximum charge current | 80 A[3] |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | 40 A[3] |
| Compatible batteries / BMS | Lead acid or lithium battery[3] |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | 5.5 kW[3]Calculated |
| Maximum PV voltage (Voc) | 500 V[3] |
| MPPT voltage range | 120 to 450 V[3] |
| MPPT trackers | ? |
| String inputs per MPPT | ? |
| PV current per MPPT | 22 A[3] |
| PV short-circuit current | ? |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 90 %[3] |
|---|---|
| CEC weighted efficiency | ? |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | Off-grid[3] |
| Generator input | Mains or generator connects at the AC input; the dry contact can switch a diesel generator[3] |
| Transfer time | 10 ms[3] |
| Idle consumption | ? |
| Parallel units | ? |
Communication and environment
| Communications | USB; RS485; WiFi/GPRS; dry node control[3] |
|---|---|
| Operating temperature | -10 to 55 °C[3] |
| Enclosure rating | ? |
| Operating noise | ? |
Mechanical
| Dimensions | 426 D × 322 D × 126 D mm[3] |
|---|---|
| Weight | 11.5 kg / 25.35 lb[3] |
Installation (from the manual)
Conductors
| Battery conductors | 30mm2/2AWG[3] |
|---|---|
| AC input conductors | 10mm²/7AWG[3] |
| AC output conductors | 10mm²/7AWG[3] |
| PV conductors | 6mm2/10AWG[3] |
| Ground conductor | not less than 4mm2[3] |
Protection
| AC input breaker | 2P—63A[3] |
|---|---|
| AC output breaker | 2P—63A[3] |
| Battery fuse or breaker | 2P—160A[3] |
| PV disconnect | 2P—25A[3] |
Clearances and orientation
| Installation clearances | Top 500mm, bottom 500mm, left 200mm, right 200mm[3] |
|---|---|
| Mounting orientation | ? |
Grounding
| Grounding and neutral-ground bonding | The ground wire is connected to the ground screw hold through Oshaped terminal.[3] |
|---|
Communication
| Communication ports | RS485 communication port; USB communication port; WIFI communication port; Dry contact port[3] |
|---|
Not in the manual: Torque
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.