Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "3/(N)/PE". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Output AC (Grid side) / Rated grid voltage" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. apparent output power 1.6 times of rated power with 2 s" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Output AC (Back-up) table; "1.6 times of rated power with 2 s" is printed in one cell spanning the 30K03, 40K04, 50K04 and 60K04 columns. This is the back-up output row, printed as a multiple of rated power; no kVA figure is printed for it. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "3/(N)/PE, 480 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Output AC (Grid side) / Rated grid voltage" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "60 Hz". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Output AC (Grid side) / Rated grid frequency" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. charge / discharge current 70 A × 2" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Battery table; "70 A × 2" is printed in one cell spanning the 30K03, 40K04, 50K04 and 60K04 columns. The datasheet prints "70 A × 2" with the footnote "Supporting parallel 140A input."; the value recorded is the per-port figure. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "3/(N)/PE". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Output AC (Grid side) / Rated grid voltage" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. apparent output power 1.6 times of rated power with 2 s" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Output AC (Back-up) table; "1.6 times of rated power with 2 s" is printed in one cell spanning the 30K03, 40K04, 50K04 and 60K04 columns. This is the back-up output row, printed as a multiple of rated power; no kVA figure is printed for it. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "3/(N)/PE, 480 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Output AC (Grid side) / Rated grid voltage" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. charge / discharge current 70 A × 2" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Battery table; "70 A × 2" is printed in one cell spanning the 30K03, 40K04, 50K04 and 60K04 columns. The datasheet prints "70 A × 2" with the footnote "Supporting parallel 140A input."; the value recorded is the per-port figure. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "97.9%". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Efficiency / Max. efficiency" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Rated grid frequency 60 Hz" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Output AC (Grid side) table; "60 Hz" is printed in one cell spanning the 30K03, 40K04, 50K04 and 60K04 columns. Read on September 25, 2026.
Three-phase grid-tied energy storage inverter with generator input and a three-phase back-up output. Compliance list includes UL 1741 SB, IEEE 1547-2018, California Rule 21 and Hawaii Rule 14H.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "60.1 A". Conditions as stated in that document. No value was taken from another model or from a product name.
Printed as "Rated grid voltage 3/(N)/PE, 480 V" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Output AC (Grid side) table; "3/(N)/PE, 480 V" is printed in one cell spanning the 30K03, 40K04, 50K04 and 60K04 columns. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "50 kVA". Conditions as stated in that document. No value was taken from another model or from a product name.
Printed as "Max. AC passthrough current 72.2 A 96.2 A 120.2 A 144.4 A" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Input AC (Grid side) table; the 50K04 column reads "120.2 A". Read on September 25, 2026.
The recorded figure ("< 35 W") is Solis's "Self-consumption (night)" row, now recorded under standby consumption; no no-load figure was recorded from this flyer. The flyer was not re-read on 29 September 2026: robots.txt on solisinverters.com now disallows /uploads/file/, and the site archive holds no copy. Row label and figure are as recorded from the capture of September 13, 2026. Revised on 29 September 2026: The recorded 35 W is a night self-consumption figure, not a no-load draw (idle consumption on this site is the invert-mode no-load draw; HANDBOOK 5, printed synonyms rule, treats night, standby, search and power-saver figures as different quantities). The figure is kept, with its source, as standby consumption.
Location: flyer V2.1 PDF page 2 DATASHEET table, "General Data / Self-consumption (night)" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. charge / discharge power 33 kW 44 kW 55 kW 60 kW" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Battery table; the 50K04 column reads "55 kW". One figure is printed for charge and discharge. Read on September 25, 2026.
Printed as "< 35 W"; the figure is an upper bound.Official datasheetSources
Printed: "< 35 W" in the "Self-consumption (night)" row of the Solis S6-EH3P(30-60)K-US flyer V2.1, as recorded from that document. The flyer was not re-read on 29 September 2026: robots.txt on solisinverters.com now disallows /uploads/file/, and the site archive holds no copy. Row label and figure are as recorded from the capture of September 13, 2026.
Location: flyer V2.1 PDF page 2 DATASHEET table, "General Data / Self-consumption (night)" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. charge / discharge power 33 kW 44 kW 55 kW 60 kW" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Battery table; the 50K04 column reads "55 kW". One figure is printed for charge and discharge. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "150 - 800 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Battery / Battery voltage range" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Solis prints the maximum output of the S6-EH3P50K04-NV-YD-H-US only as apparent power ("Max. apparent output power 30 kVA 40 kVA 50 kVA 60 kVA"), recorded under apparent power; its kW row ("Rated output power 30 kW 40 kW 50 kW 60 kW") is the rated output, already recorded as continuous output. Revised on 12 October 2026: this kilowatt field held 50 kVA; it is kept in this note.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "97.4%". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Efficiency / CEC efficiency" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "150 - 850 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Input DC (PV side) / MPPT voltage range" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "MPPT number / Max. input strings number 3 / 6 4 / 8" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Input DC (PV side) table; "4 / 8" is printed in one cell spanning the 40K04, 50K04 and 60K04 columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "1000 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Input DC (PV side) / Max. input voltage" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "180 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Input DC (PV side) / Start-up voltage" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Printed as "Max. short circuit current 65 A / 65 A / 65 A 4 × 65 A" in the Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1), Input DC (PV side) table; "4 × 65 A" is printed in one cell spanning the 40K04, 50K04 and 60K04 columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-EH3P(30-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-EH3P50K04-NV-YD-H-US. Printed: "60 Hz". Conditions as stated in that document. No value was taken from another model or from a product name.
Location: flyer V2.1 PDF page 2 DATASHEET table, "Output AC (Grid side) / Rated grid frequency" row (single value spanning all four model columns 30K03/40K04/50K04/60K04)
Documented
Dimensions
203.74 L*Calculated: Enclosure volume: W × H × D ÷ 1,000,000
Ground fault detection, residual (leakage) current detection, integrated AFCI, DC reverse-polarity protection, PV DC switch and an integrated SunSpec-certified rapid shutdown transmitter for NEC 2017. Protection class I, overvoltage category II.
Published claims and calculations, not independent test results.
Documents
4 on file
PDF
Solis S6-EH3P(30-60)K-NV-YD-H-US datasheetOfficialSolis (Ginlong Technologies)Official datasheet
Certificate & compliance claims (9)
UL 1741 SBManufacturer claim · equipment listingClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
UL 1699BManufacturer claim · equipment listingClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
UL 1998Manufacturer claim · equipment listingClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
FCCPart15ClassBManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
California Rule21Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Hawaii Rule 14HManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
NEC 690.12-2020Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Solis Standard Limited Warranty Document for North America (Solis North America knowledge base)OfficialGinlong (Ningbo) Technologies Co., Ltd.Official warranty
Source details
Revision
Not stated
Revision date
Not stated
Archived copy captured on 2026-09-25.
Location: Section C and Appendix A
Retrieved
Solis North America knowledge base article on usservice.solisinverters.com, linked from the Solis US product pages and captured on September 25, 2026. Appendix A sets the limited warranty period by product category for the United States and Canada market; the terms apply to products produced on and from July 01, 2025. It names categories, not model numbers.
Solis publishes this datasheet for S6-EH3P30K03-NV-YD-H-US and names no other model in this catalog on it. Read from https://www.solisinverters.com/us/energy_storage_inverters16/S6-EH3P(30-60)K-NV-YD-H-US_us.html on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Location: Document title as published
Retrieved
Solis publishes this datasheet for S6-EH3P30K03-NV-YD-H-US and names no other model in this catalog on it. Read from https://www.solisinverters.com/us/energy_storage_inverters16/S6-EH3P(30-60)K-NV-YD-H-US_us.html on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Printed as "Solis Energy Storage Inverter on Sale (Except Utility) 10 Years" in Appendix A of the Solis Standard Limited Warranty Document for North America, which applies to the United States and Canada market and to products produced on and from July 01, 2025. The article sets the period by product category and does not name this model; this model is a Solis US energy storage (hybrid) inverter per its own manual. For an individual buyer the period starts on the date of sale. Read on September 25, 2026.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Solis Energy Storage Inverter on Sale (Except Utility) 10 Years" in Appendix A of the Solis Standard Limited Warranty Document for North America, which applies to the United States and Canada market and to products produced on and from July 01, 2025. The article sets the period by product category and does not name this model; this model is a Solis US energy storage (hybrid) inverter per its own manual. For an individual buyer the period starts on the date of sale. Read on September 25, 2026.
The recorded figure ("< 35 W") is Solis's "Self-consumption (night)" row, now recorded under standby consumption; no no-load figure was recorded from this flyer. The flyer was not re-read on 29 September 2026: robots.txt on solisinverters.com now disallows /uploads/file/, and the site archive holds no copy. Row label and figure are as recorded from the capture of September 13, 2026. Revised on 29 September 2026: The recorded 35 W is a night self-consumption figure, not a no-load draw (idle consumption on this site is the invert-mode no-load draw; HANDBOOK 5, printed synonyms rule, treats night, standby, search and power-saver figures as different quantities). The figure is kept, with its source, as standby consumption.
Not documented, 0 points: Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 15 to 50 kW output band. · Method version 0.5
UL 1741 SBProduct / system scope unresolvedClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
IEEE 1547-2018Product / system scope unresolvedClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
UL 1699BProduct / system scope unresolvedClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
UL 1998Product / system scope unresolvedClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
CAN/CSA C22.2 107.1-1Product / system scope unresolvedClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
FCCPart15ClassBProduct / system scope unresolvedClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; Read on September 25, 2026.
California Rule21Product / system scope unresolvedClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; Read on September 25, 2026.
Hawaii Rule 14HProduct / system scope unresolvedClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; Read on September 25, 2026.
NEC 690.12-2020Product / system scope unresolvedClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; Read on September 25, 2026.
CECProduct / system scope unresolvedClaimedListed when checked
Model S6-EH3P50K04-NV-YD-H-US listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Ginlong Technologies Co., Ltd., as "S6-EH3P50K04-NV-YD-H-US {480V}", CEC listing date 2025-10-01. Solis's own site (Privacy Policy page on solisinverters.com (US); footer of the same site also reads "Copyright@2019 Ginlong Technologies All Rights Reserved") names Ginlong Technologies Co., Ltd.: "Ginlong Technologies Co.,Ltd. is a limited liability company established in accordance with the laws of the People's Republic of China (hereinafter referred to as "Ginlong" or "we")". This is an equipment listing, not UL certification or complete-system approval.
CECProduct / system scope unresolvedClaimedListed when checked
Model S6-EH3P50K04-NV-YD-H-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Ginlong Technologies Co., Ltd., as "S6-EH3P50K04-NV-YD-H-US {480V}", CEC listing date 2025-10-01. Solis's own site (Privacy Policy page on solisinverters.com (US); footer of the same site also reads "Copyright@2019 Ginlong Technologies All Rights Reserved") names Ginlong Technologies Co., Ltd.: "Ginlong Technologies Co.,Ltd. is a limited liability company established in accordance with the laws of the People's Republic of China (hereinafter referred to as "Ginlong" or "we")". This is an equipment listing, not UL certification or complete-system approval.
UL 1741 SBManufacturer claim · equipment listingClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
UL 1699BManufacturer claim · equipment listingClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
UL 1998Manufacturer claim · equipment listingClaimedStatus unconfirmed
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
FCCPart15ClassBManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
California Rule21Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Hawaii Rule 14HManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
NEC 690.12-2020Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH3P(30-60)K-NV-YD-H-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE1547-2018, UL1699B, UL1998, FCCPart15ClassB, California Rule21, Hawaii Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
S6-EH3P50K04-NV-YD-H-US
Manufacturer SKU S6-EH3P50K04-NV-YD-H-US · US market
Observed
CEC: claimed
Product / system scope unresolved. Model S6-EH3P50K04-NV-YD-H-US listed on the California Energy Commission Grid Support Battery Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Ginlong Technologies Co., Ltd., as "S6-EH3P50K04-NV-YD-H-US {480V}", CEC listing date 2025-10-01. Solis's own site (Privacy Policy page on solisinverters.com (US); footer of the same site also reads "Copyright@2019 Ginlong Technologies All Rights Reserved") names Ginlong Technologies Co., Ltd.: "Ginlong Technologies Co.,Ltd. is a limited liability company established in accordance with the laws of the People's Republic of China (hereinafter referred to as "Ginlong" or "we")". This is an equipment listing, not UL certification or complete-system approval.
Product / system scope unresolved. Model S6-EH3P50K04-NV-YD-H-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Ginlong Technologies Co., Ltd., as "S6-EH3P50K04-NV-YD-H-US {480V}", CEC listing date 2025-10-01. Solis's own site (Privacy Policy page on solisinverters.com (US); footer of the same site also reads "Copyright@2019 Ginlong Technologies All Rights Reserved") names Ginlong Technologies Co., Ltd.: "Ginlong Technologies Co.,Ltd. is a limited liability company established in accordance with the laws of the People's Republic of China (hereinafter referred to as "Ginlong" or "we")". This is an equipment listing, not UL certification or complete-system approval.
Product / system scope unresolved. Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Product / system scope unresolved. Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Product / system scope unresolved. Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Product / system scope unresolved. Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.
Product / system scope unresolved. Datasheet "Compliance" row: UL 1741 SB, IEEE 1547-2018, UL 1699B, UL 1998, FCC Part 15 Class B, California Rule 21, Hawaii Rule 14H, NEC 690.12-2020 and CAN/CSA C22.2 107.1-1. Manufacturer claim; issuer file number, certificate edition and current status were not independently checked.