Charged ReviewsSaved 0Compare 0Login
Schneider Electric Conext SW 4048 120/240 Split-phase (865-4048-21)
Schneider Electric
Inverter charger

Schneider Electric Conext SW 4048 120/240 Split-phase (865-4048-21)

Key specs

Weight30.5 kg / 67.2 lb converted Check note
Nominal voltage48 V DC
Efficiency94 %
Continuous output3.8 kW
Converted: 3800 W / 1000 W per kW = 3.8 kW
Max charge45 A
AC frequency50 or 60 Hz (selectable); 60 Hz default

All specifications

Identity

BrandSchneider Electric · Website
ModelConext SW 4048 120/240
MarketUnknown
Manufacturer SKU865-4048-21
SKU detail
locator: Cover and Copyright and Contact page, Product Part Numbers line
conditions: Part number as printed by Schneider Electric on the covers of the 2020 owner's and installation guides, in the datasheet's Part number row and in the se.com page heading.
Sources: [1] [2] [3] [4]
FieldValueConditionsSource
Weight30.5 kg / 67.2 lb converted Check note
The datasheet prints a lower weight. Schneider Electric's datasheet (DS20220511_SW_NA) prints "Product weight" as "28.1 kg (62.0 lb)" for the SW 4048 120/240. The owner's guide 975-0638-01-03 and installation guide print 67.2 lbs. (30.5 kg), which is recorded.
Printed as "67.2 lbs. (30.5 kg)" unit net weight. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Physical Specifications, Unit Net Weight row
[1]
Peak output4400 W for 30 min; 7000 W for 5 s
Printed as 4400 W for 30 minutes (only when NoLoadVD is enabled) and 7000 W for 5 seconds, at 25 °C. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, Continuous output power (AC) and Surge power rating rows
[1]
Service endApril 4, 2035
Printed as "To be end-of-service on: Apr 4, 2035"; the page defines end of standard service as the last date Schneider Electric can provide maintenance services such as repair and spare parts. Not a warranty term.
Where: Product page commercial status block
[4]
AC voltage120/240 VAC
Printed as nominal voltage "120/240 VAC" single-phase/split-phase; the operating voltage range is 104/208 VAC to 127/254 VAC. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, Nominal voltage single-phase/split-phase row
[1]
Max charge45 A
Printed as "45 A" maximum charger output current. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Charger Specifications, Maximum output current row; datasheet charger Output current row
[1] [3]
DimensionsW 343 × H 197 × L 387 mm / W 13.5 × H 7.76 × L 15.2 in converted Check note
The datasheet prints different dimensions. Schneider Electric's datasheet (DS20220511_SW_NA) prints "Product dimensions (H x W x D)" as "41.8 x 34.1 x 19.7 cm (16.5 x 13.4 x 7.6 in)". The owner's guide 975-0638-01-03 and installation guide print 387×343×197 mm (L × W × H), which is recorded.
Printed as "15.2×13.5×7.6 in (387×343×197 mm)" (L × W × H); the millimeter figures are recorded. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Physical Specifications, L × W × H row
[1]
Efficiency94 %
Peak inverter efficiency, printed as "94%". Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, Peak efficiency row
[1] [3]
Product statusDiscontinued
Schneider Electric's se.com page for 865-4048-21 prints "Discontinued on: Jul 26, 2025" and says the part "has not been replaced". Reseller stock and continued service are separate.
Where: Product page commercial status block
[4]
AC frequency50 or 60 Hz (selectable); 60 Hz default
Printed as operating frequency range "selectable 50 or 60 Hz" and default output frequency "60 Hz". Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, Operating frequency range and Default output frequency rows
[1]
AC configurationSplit-phase (L1/L2)
Printed as AC OUTPUT connection "Split-phase (L1/L2)". Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, AC OUTPUT connection row
[1]
Enclosure ratingIndoor only, IP 20
Printed as ingress protection rating "Indoor only, IP 20" for all models; manufacturer claim. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Environmental Specifications, Ingress protection rating row (all models)
[1]
Transfer time< 20 ms
Printed as "< 20 ms" in the Transfer time (utility to inverter) row for all models. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: AC Transfer Specifications, Transfer time row (all models)
[1]
Nominal voltage48 V DC
Printed as "48 VDC" nominal output voltage. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Charger Specifications, Nominal output voltage row
[1]
Surge AC output7,000 W
Printed as "7000 W" surge power rating for 5 seconds. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, Surge power rating (5 seconds) row
[1] [3]
Grid passthrough30 A
Printed as relay current rating "30 A" for all models, with the footnote "Limited by SCP to 24 A due to CEC/NEC regulatory requirements." Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: AC Transfer Specifications, Relay current rating row (all models)
[1]
Idle consumption27 W
Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Specifications, No-load power draw (Inverter On) row
[1]
Continuous output3.8 kW
Converted: 3800 W / 1000 W per kW = 3.8 kW
Printed as "3800 W" maximum continuous output (footnote: only when NoLoadVD is enabled) and 4400 W for 30 minutes, at 25 °C. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Specifications chapter, Inverter Specifications, Continuous output power (AC), SW 4048 120/240 column
Sources
Converted: 3800 W / 1000 W per kW = 3.8 kW
[1] [3]
Continuous AC output15.2 A
Printed as "15.2 A" maximum continuous output current; the inverter peak output current is 41 A. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, Maximum continuous output current row
[1]
Battery voltage range40 to 64 V Check note
The datasheet prints a wider range. Schneider Electric's datasheet (DS20220511_SW_NA) prints "Input DC voltage range" as "40 - 68 Vdc" for the SW 4048 120/240. The owner's guide 975-0638-01-03 and installation guide print 40–64 VDC, which is recorded.
Printed as "40–64 VDC" DC input voltage range; the maximum continuous power voltage range is 46–48 VDC. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Inverter Specifications, DC Input, Voltage range row
[1]
Operating temperature-20 to 60 °C / -4 to 140 °F converted
Printed as "–4 to 140 °F (–20 to 60 °C)", starting to derate above 77 °F (25 °C). Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).
Where: Environmental Specifications, Operating temperature range row (all models)
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3.8 kW
Battery voltage
40 to 64 V
Solar input
Not statedMPPT trackers Not stated
AC output
Split-phase (L1/L2)
Warranty
Not stated
Size
26.15 L* (Calculated from published dimensions)W: 343 × H: 197 × L: 387 mm / W: 13.5 × H: 7.76 × L: 15.2 inWeight 30.5 kg / 67.2 lb

Evidence score

11/100Missing details55% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 +1Claimed10.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[1]

Idle consumption27 W0.4 / 10.0

27 against 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band (printed by the maker): Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.

Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-03, which names the Conext SW 4048 120/240 as part number 865-4048-21. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as Schneider Electric's own document prints it (PM, October 17, 2026).

[1]

Research pending, 0 points: Warranty term, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CSA C22.2 No. 107.1-01manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048-21
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0638-01-03 for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048-21
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0638-01-03 for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 120/240 V models, document 975-0638-01-03 (May 2020), linked as the user guide from Schneider Electric's se.com page for 865-4048-21.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.68 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=9_SW-NA_Owners-Guide_975-0638-01-03_Rev-3_ENG.pdf&p_Doc_Ref=SW-NA_OG_975-0638-01-03. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
122

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d037c80b45b56ad2c12a9bb77ef3211d967e141e62abfaa90ca9934628769932

Schneider Electric's own Conext SW Inverter/Charger installation guide for the 120/240 V models, document 975-0639-01-03 (May 2020), Internet Archive copy of solar.schneider-electric.com captured January 20, 2022.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 12.30 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://web.archive.org/web/20220120060605id_/https://solar.schneider-electric.com/wp-content/uploads/2020/10/ML202005_SW-NA_Installation-Guide975-0639-01-03_Rev-3_ENG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
72

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a44a50f5ab2b90d81122581f5e92bccf8adb80ef618945919d49dc98a3d7fee3

Schneider Electric's own SW inverter/charger datasheet, Technical Specifications - North America (DS20220511_SW_NA), linked as the product datasheet from Schneider Electric's se.com page for 865-4048-21.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 1.10 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=SW-UL-Datasheet.pdf&p_Doc_Ref=SW-UL_Datasheet. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 4c6d2d36d78fa363ed8a94cc559f5553c80573db47e9a416a44cbee7b3cba54b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Conext SW 4048 120/240

Manufacturer SKU 865-4048-21

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 55
basis: Unknown
missing:
Warranty term needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 22.75
unit: Unknown
shown: UL 1741 +1
shown detail: Claimed
state: claimed
points: 10.2
ceiling: 45
weight: 45
share: 22.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [1]
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 27
unit: Unknown
shown: 27 W
shown detail: Unknown
state: documented
points: 0.4
ceiling: 10
weight: 10
share: 3.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 120/240 V models, document 975-0638-01-03 (May 2020), linked as the user guide from Schneider Electric's se.com page for 865-4048-21. (Schneider Electric · manufacturer · observed Oct 3, 2026)
  2. Schneider Electric's own Conext SW Inverter/Charger installation guide for the 120/240 V models, document 975-0639-01-03 (May 2020), Internet Archive copy of solar.schneider-electric.com captured January 20, 2022. (Schneider Electric · manufacturer · observed Oct 3, 2026)
  3. Schneider Electric's own SW inverter/charger datasheet, Technical Specifications - North America (DS20220511_SW_NA), linked as the product datasheet from Schneider Electric's se.com page for 865-4048-21. (Schneider Electric · manufacturer · observed Oct 3, 2026)
  4. Schneider Electric's own se.com product page for the SW 4048 3.8 kW Solar Hybrid Inverter 120/240 Vac / 48 Vdc (865-4048-21), captured October 4, 2026. (Schneider Electric · manufacturer · observed Oct 3, 2026)

Sign in to report an error on this page

Similar products

All with a price

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

* Missing details