Schneider Electric Conext SW 4048 120/240 Split-phase (865-4048-21)

Brand
Schneider Electric
Model
Conext SW 4048 120/240
SKU / part number
865-4048-21 [1] [2] [3] [4]
Category
Inverters

chargedreviews.com/inverters/schneider-electric-865-4048-21

AC output

Continuous output
3.8 kW [1] [3]
Peak output
4400 W for 30 min; 7000 W for 5 s [1]
AC configuration
Split-phase (L1/L2) [1]
AC output voltage
120/240 VAC [1]
AC frequency
50 or 60 Hz (selectable); 60 Hz default [1]
Grid pass-through
30 A [1]
Maximum output per leg
?

Battery

Battery voltage
48 V DC [1]
Battery voltage range
40 to 64 V Needs confirmation [1]
Maximum charge current
45 A [1] [3]
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
?
MPPT voltage range
?
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
?
PV short-circuit current
?
PV startup voltage
?

Efficiency and modes

Peak efficiency
94 % [1] [3]
CEC weighted efficiency
?
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
?
Transfer time
< 20 ms [1]
Idle consumption
27 W [1]
Parallel units
?

Communication and environment

Communications
?
Operating temperature
-20 to 60 °C / -4 to 140 °F converted [1]
Enclosure rating
Indoor only, IP 20 [1]
Operating noise
?

Mechanical

Dimensions
W 343 × H 197 × L 387 mm / W 13.5 × H 7.76 × L 15.2 in converted Needs confirmation [1]
Weight
30.5 kg / 67.2 lb converted Needs confirmation [1]

Installation (from the manual)

Not documented in the manual

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Schneider Electric Conext SW 4048 120/240 Split-phase (865-4048-21) · Conext SW 4048 120/240

Warranty

Warranty term?
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741Claimed present at observation [1]
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?
CSA C22.2 No. 107.1-01Claimed present at observation [1]

Documents and sources

  1. Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 120/240 V models, document 975-0638-01-03 (May 2020), linked as the user guide from Schneider Electric's se.com page for 865-4048-21. Manufacturer owner's guide (PDF) · Checked Oct 3, 2026 https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=9_SW-NA_Owners-Guide_975-0638-01-03_Rev-3_ENG.pdf&p_Doc_Ref=SW-NA_OG_975-0638-01-03
  2. Schneider Electric's own Conext SW Inverter/Charger installation guide for the 120/240 V models, document 975-0639-01-03 (May 2020), Internet Archive copy of solar.schneider-electric.com captured January 20, 2022. Manufacturer installation guide (PDF, Internet Archive copy) · Checked Oct 3, 2026 https://web.archive.org/web/20220120060605id_/https://solar.schneider-electric.com/wp-content/uploads/2020/10/ML202005_SW-NA_Installation-Guide975-0639-01-03_Rev-3_ENG.pdf
  3. Schneider Electric's own SW inverter/charger datasheet, Technical Specifications - North America (DS20220511_SW_NA), linked as the product datasheet from Schneider Electric's se.com page for 865-4048-21. Manufacturer datasheet (PDF) · Checked Oct 3, 2026 https://download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=SW-UL-Datasheet.pdf&p_Doc_Ref=SW-UL_Datasheet
  4. Schneider Electric's own se.com product page for the SW 4048 3.8 kW Solar Hybrid Inverter 120/240 Vac / 48 Vdc (865-4048-21), captured October 4, 2026. Manufacturer product page · Checked Oct 3, 2026 https://www.se.com/us/en/product/865-4048-21/

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/schneider-electric-865-4048-21Some links pay us a commission. That does not affect what we record.