About brandPowMr sells off-grid and hybrid solar inverters, MPPT and PWM solar charge controllers, LiFePO4 batteries and solar panels under its own name through its store at powmr.com.
SKU detail
locator: SKU line under the product title
conditions: PowMr's product page, captured on October 13, 2026, prints "SKU: POW-RELAB 5KU-SPLIT" for this listing.
The manual prints "Dimensions (LxWxH) 465*310*135mm 545*400*200mm"; the 545*400*200mm cell spans the 5KU-SPLIT and 10KU-SPLIT columns. The catalog prints 545x400x200mm in its own 5KU-SPLIT column.
Where: PDF page 43 (printed page 40), 8.4 Table 4: General Parameters, Dimensions (LxWxH)
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) and the POW-RELAB 5KU-SPLIT product page print a 5400W PV array, a 60~245Vdc MPPT range and a 245Vdc maximum open-circuit voltage, and the manual a 100A maximum PV charging current; PowMr's 2026 catalog prints 6400W, 60~105Vdc, 105Vdc and 120A for this model.
The product page's single-model table prints "PV Array MPPT Voltage Range (V) 60~245"; the manual prints "MPPT Input Voltage Range 30~245Vdc 60~245Vdc" with the 60~245Vdc cell spanning the 5KU-SPLIT and 10KU-SPLIT columns. The catalog prints a different range, kept as an alternative.
Where: Product page Specifications, PV Array MPPT Voltage Range (V); manual Table 3, MPPT Input Voltage Range
Sources
60 to 105 V
The 2026 catalog prints "PV Array MPPT Range" 60~105Vdc in its own 5KU-SPLIT column.
5.4 kW*Converted: 5400 W / 1000 W per kW = 5.4 kWCheck note
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) and the POW-RELAB 5KU-SPLIT product page print a 5400W PV array, a 60~245Vdc MPPT range and a 245Vdc maximum open-circuit voltage, and the manual a 100A maximum PV charging current; PowMr's 2026 catalog prints 6400W, 60~105Vdc, 105Vdc and 120A for this model.
The product page's single-model table prints "Max Solar Panel Input Power (W) 5400" and "PV Max Power 5400W". The manual prints "Max. PV Array Power 2700W 5400W" with the 5400W cell spanning the 5KU-SPLIT and 10KU-SPLIT columns. The catalog prints a different figure, kept as an alternative. Manufacturer claim, not an independent test.
Where: Product page Specifications, Max Solar Panel Input Power (W); manual Table 3, Max. PV Array Power
Sources
Converted: 5400 W / 1000 W per kW = 5.4 kW
6.4 kW
The 2026 catalog prints "Max. PV Array Power" 6400W in its own 5KU-SPLIT column (6400 W / 1000 = 6.4 kW).
The manual prints "Max. AC Charging Current 38A 50A 105A" in separate model columns; 50A is the POW-RELAB 5KU-SPLIT column. The catalog prints 50A in its 5KU-SPLIT column.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Max. AC Charging Current
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) and the POW-RELAB 5KU-SPLIT product page print a 5400W PV array, a 60~245Vdc MPPT range and a 245Vdc maximum open-circuit voltage, and the manual a 100A maximum PV charging current; PowMr's 2026 catalog prints 6400W, 60~105Vdc, 105Vdc and 120A for this model.
The manual prints "Max. PV Charging Current 100A" in a cell spanning all three model columns. The 2026 catalog prints a different figure, kept as an alternative.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Max. PV Charging Current
Sources
120 A
The 2026 catalog prints "Max. PV Charging Current" 120A in its own 5KU-SPLIT column.
110 V N-L1 / N-L2 and 220 V L1-L2 split phase, 50/60 Hz
The manual prints "Nominal Output Voltage 110Vac(N-L1/N-L2)/ 220Vac(L1-L2)" and "Output Frequency 50Hz / 60Hz" in cells spanning all three model columns. The product page prints "AC Output (V) 120/240" for this model.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Nominal Output Voltage and Output Frequency
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) and the POW-RELAB 5KU-SPLIT product page print a 5400W PV array, a 60~245Vdc MPPT range and a 245Vdc maximum open-circuit voltage, and the manual a 100A maximum PV charging current; PowMr's 2026 catalog prints 6400W, 60~105Vdc, 105Vdc and 120A for this model.
The product page's single-model table prints "PV Max Voltage 245Vdc"; the manual prints "Max. PV Array Open Circuit Voltage 245Vdc 245Vdc", 245Vdc for every column. The catalog prints a different figure, kept as an alternative.
Where: Product page Specifications, PV Max Voltage; manual Table 3, Max. PV Array Open Circuit Voltage
Sources
105 V
The 2026 catalog prints "Max. PV Array Open Circuit Voltage" 105Vdc in a cell spanning all three RELAB-SPLIT columns.
The product page's single-model table prints "DC Output (V) 48"; the catalog prints "System Voltage" 48V in its own 5KU-SPLIT column. The manual prints "Nominal DC Input Voltage 24Vdc 48Vdc" with the 48Vdc cell spanning the 5KU-SPLIT and 10KU-SPLIT columns.
Where: Product page Specifications, DC Output (V); manual Table 2, Nominal DC Input Voltage
The manual prints "Peak Power 9000W 15000W 30000W" in separate model columns; 15000W is the POW-RELAB 5KU-SPLIT column. No duration is printed there; the catalog prints "Surge Capacity 2*rated power for 5 seconds" across the series.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Peak Power
The manual prints "Rated Output Power 3000W 5000W 10000W" in separate model columns; 5000W is the POW-RELAB 5KU-SPLIT column. The product page prints "Rated Load Power (W) 5000". The catalog prints 5000W in its own POW-RELAB 5KU-SPLIT column. Manufacturer claim, not an independent test.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Rated Output Power
The manual prints "Battery Charging Voltage 27.4VDC 54.8VDC"; the 27.4VDC cell is the 3KU-SPLIT column and the 54.8VDC cell spans the 5KU-SPLIT and 10KU-SPLIT columns.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Battery Charging Voltage
5.4 kWMPPT trackersNot statedMPPT range60 to 245 V
AC output
110 V N-L1 / N-L2 and 220 V L1-L2 split phase, 50/60 Hz
Warranty
Not stated
Size
Unknown545x400x200mmWeight27.4 kg / 60.4 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
Location: 8 Specifications, Tables 1 to 4, PDF pages 41 to 43 (rendered and read)
Retrieved Oct 12, 2026
The English user manual for the POW-RELAB 3KU-SPLIT, 5KU-SPLIT and 10KU-SPLIT that PowMr's site menu links, served from its Shopify file store and captured on October 13, 2026. Its specification tables (PDF pages 41 to 43, printed pages 38 to 40) have one column per model; several cells span two or three columns and were read from the rendered pages. The file name gives version V2.1.0403; no date is printed. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: PDF pages 116 and 120 (rendered and read)
Retrieved Oct 9, 2026
PowMr's 2026 product catalog, linked as "PowMr Brochure 2026" from every page of PowMr's store and served from its Shopify file store, captured on October 9, 2026. Its specification tables for the POW-M60-ULTRA (PDF page 116) and the POW-M80-PRO and POW-M100-PRO (PDF page 120) are laid out so that the extracted text separates labels from values; those pages were rendered and read directly, and figures cite the rendered PDF page. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
PowMr's own store page at powmr.com, captured on October 13, 2026; the content is whatever the address served on that date. Only the page's own description, its SKU line and its single-model Specifications block are read; the page's product comparison table is not used. The page prints no market or region and carries no revision date. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
PowMr POW-RELAB-SPLIT series user manual V2.1 (PDF, English)
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].