SunGoldPower's own product data, captured 2026-10-27, prints SKU "SPH5048P" for option "SPH5048P [Parallel, 100A MPPT] / Only Inverter" (variant 44404161478793) of listing "5000W 48V Solar Charger Inverter".
Printed as "The ground wire is connected to the grounding screw hole on the cabinet through the O-type terminal." (PDF page 13) and, for setting item 63 "N-G automatically connect", "[63] DIS Default Disable automatic switching of N-G connection" (PDF page 42) in the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7.
Printed as "Anti-backflow grid connection function, support for inverter and mains power hybrid output, support for use without battery, can be set up for on-grid power generation." (feature 1, PDF page 5) in the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7. The same manual's safety instructions (PDF page 3) also print "The all-in-one solar storage inverter is off-grid.", and the technical table prints an "AC Output(Grid)" section with a rated output power of 5000 W.
Location: User manual V2.7 (SPH5048P_User_Manual_V2.7_20250611.pdf), section 7 Technical parameters, AC charging, Maximum charge current(can be set) row
Location: User manual V2.7 (SPH5048P_User_Manual_V2.7_20250611.pdf), section 7 Technical parameters, AC mode, Conversion time (bypass and inverter) row
Printed as "45~50W" (a range, kept as printed). The sheet text is flattened: labels come first, then the SPH302480A values, then the SPH5048P values (10000VA, 48VDC, 63A, 45~50W, 25W, 5500W, 0-100A, 500V), which match the SPH5048P manual. The following "25W" is the Power Saver Mode Idle Consumption.
Printed as "Battery type Lead acid or lithium battery" in the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7. Setting item 33 (PDF page 40) lists the lithium battery BMS protocols for the RS485-2 port.
Printed as "40-60Vdc" in the PV charging section. The inverter-mode Battery voltage range row gives no numbers (settable on the LCD screen) and the AC charging section prints a charge voltage range of 40-58Vdc.
Location: User manual V2.7 (SPH5048P_User_Manual_V2.7_20250611.pdf), section 7 Technical parameters, PV charging, PV charging current range (can be set) row
Printed as "The ground wire is connected to the grounding screw hole on the cabinet through the O-type terminal." (PDF page 13) and, for setting item 63 "N-G automatically connect", "[63] DIS Default Disable automatic switching of N-G connection" (PDF page 42) in the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7.
Printed as "SPH5048P 4mm2/12AWG 22A 2P—25A" in the PV input table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7. A reference size only.
Read from rendered page 11: the installation diagram labels 500mm above and below the unit and 200mm to the left and right. The step text is printed as "space of at least 200m m to the left and right air outlets". From the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7.
Printed as "SPH5048P 4mm2/12AWG 22A 2P—25A" in the PV input table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7. In parallel use the manual says "different machines need to be connected to different PV arrays or PV sources".
Printed as "SPH5048P 10mm2/8AWG 63A 2P—63A" in the AC input table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7, with the note "There is already an appropriate circuit breaker at the Mains input wiring terminal, so it is not necessary to add one more."
Printed as "SPH5048P 35mm2/2AWG 125A 100A 2P—200A" in the battery table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7 (rated battery discharge current 125A, maximum charge current 100A). A reference size only.
Printed as "Mains or generator: Connected at the AC input, to power the load while charging the battery." (PDF page 6) in the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7; the dry contact section (PDF page 45) describes control of a diesel generator.
Printed as "SPH5048P 10mm2/8AWG 63A 2P—63A" in the AC input table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7 (maximum bypass input current 63A). A reference size only.
Printed as "SPH5048P 35mm2/2AWG 125A 100A 2P—200A" in the battery table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7; the wiring warnings (PDF page 15) say "a circuit breaker must be installed at the battery terminal".
Printed as "SPH5048P 10mm2/8AWG 42A 63A 2P—63A" in the AC output table of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7 (rated inverter AC output current 42A, maximum bypass output current 63A). A reference size only.
Location: PDF page 10, section 2.2 Wiring specifications and circuit breaker selection, AC output table, Recommended AC output wiring diameter column, SPH5048P row
Documented
Communication ports (manual)
RS485 communication port; Current sharing port (parallel module only); Parallel communication port (parallel module only); USB communication port; WIFI communication port; Dry contact port
Printed as "⑤ RS485 communication port", "⑥ Current sharing port (parallel module only)", "USB communication port", "WIFI communication port" and "⑩ Dry contact port" in the appearance legend of the SPH5048P "All-in-one solar charge inverter" user manual Version V2.7; item 7 is the "Parallel communication port (parallel module only)".
Location: User manual V2.7 (SPH5048P_User_Manual_V2.7_20250611.pdf), section 7 Technical parameters, Certified specifications, Operating temperature range row
Original manufacturer-hosted PDF preserved byte for byte, linked from the manufacturer's own product page for SKU SPH5048P. The revision is whatever was published at this URL on the access date; no later revision was checked and no separate variant coverage is claimed beyond the page that linked it.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
5000W 48V Solar Charger Inverter SPH504880A User ManualOfficialSunGoldPowerOfficial instruction manual
Source details
Revision
Not stated
Revision date
Not stated
SunGoldPower publishes this instruction manual for SPH5048P, among other models named on the same document. Read from https://sungoldpower.com/collections/power-inverter on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Location: Document title as published
Retrieved
SunGoldPower publishes this instruction manual for SPH5048P, among other models named on the same document. Read from https://sungoldpower.com/collections/power-inverter on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Location: Product heading; Highlight list; Specification and User Manual tabs (manual-download-button links)
Retrieved
SunGoldPower's own product page, captured byte for byte on September 23, 2026. It establishes what SunGoldPower published for SPH5048P, SPH504880A on that date: the page heading, the Highlight text, the variant selector (SKUs SPH5048P, SPH5048P+SG48100P, SPH504880A, SPH504880A+SG48100P) and the 5 document link(s) under its User Manual tab. Prices and stock on the page are the state of a promotional storefront and are not recorded from it. A specification quoted from the page is SunGoldPower's own published figure, not a test result.
CE(IEC62109-1)Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
FCCManufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
UL1741Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
EN61000Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
Linked from https://sungoldpower.com/products/5000w-48v-solar-charger-inverter with link text "none".
Location: SPH5048P_User_Manual_V2.7_20250611.pdf
Retrieved
Original manufacturer-hosted PDF preserved byte for byte, linked from the manufacturer's own product page for SKU SPH5048P. The revision is whatever was published at this URL on the access date; no later revision was checked and no separate variant coverage is claimed beyond the page that linked it.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
5000W 48V Solar Charger Inverter SPH504880A User Manual
Archived copy of a document published by SunGoldPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Printed as "45~50W" (a range, kept as printed). The sheet text is flattened: labels come first, then the SPH302480A values, then the SPH5048P values (10000VA, 48VDC, 63A, 45~50W, 25W, 5500W, 0-100A, 500V), which match the SPH5048P manual. The following "25W" is the Power Saver Mode Idle Consumption.
A value is on file but is not counted: it carries a warning or is not confirmed.
Research pending, 0 points: Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
UL 1741:2021 Ed.3+R:19May2023Product / system scope unresolvedClaimedListed when checked
Intertek certificate of compliance for report 2408B1243SHA-001, issued April 10, 2026, model SPH5048P only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.
CSA C22.2#107.1:2016 Ed.4+U1Product / system scope unresolvedClaimedListed when checked
Intertek certificate of compliance for report 2408B1243SHA-001, issued April 10, 2026, model SPH5048P only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.
CE(IEC62109-1)Product / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
FCCProduct / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
UL1741Product / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
EN61000Product / system scope unresolvedClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
CE(IEC62109-1)Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
FCCManufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
UL1741Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
EN61000Manufacturer claim · equipment listingClaimedListed when checked
SunGoldPower's own statement, recorded exactly as printed: "Certification CE(IEC62109-1)/FCC/UL1741 EMC certification level EN61000" (SPH5048P_User_Manual_V2.7_20250611.pdf). A manufacturer statement names no certificate number or issuer and is not evidence of a listing; certificate documents SunGoldPower serves are recorded separately.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SPH5048P
Manufacturer SKU SPH5048P
Observed
UL 1741:2021 Ed.3+R:19May2023: claimed
Product / system scope unresolved. Intertek certificate of compliance for report 2408B1243SHA-001, issued April 10, 2026, model SPH5048P only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.
Product / system scope unresolved. Intertek certificate of compliance for report 2408B1243SHA-001, issued April 10, 2026, model SPH5048P only. The standard is recorded exactly as the certificate prints it. Read from the issuer's certificate document as SunGoldPower serves it on the product page's User Manual tab, captured September 23, 2026; the certificate's current status was not re-checked in the issuer's online directory. Recorded as a manufacturer-hosted certificate: the document was read as SunGoldPower serves it, and the issuer check remains open.