About brandAPsystems (Altenergy Power System Inc.) makes microinverters, energy storage and rapid shutdown devices for solar PV systems; it names APsmart and APstorage as its brands and says it was founded in Silicon Valley in 2010.
SKU detail
locator: User manual section 8.1, PDF page 21 (printed page 20), Model row
conditions: APsystems' own model name, printed in the Model row of the specification table; no separate part number or SKU is printed. The datasheet prints the same model and region; its text layer places the headings apart from the table, so its column was read on the rendered page.
The user manual's section 8.1 is titled "QT2D 3-Phase Microinverter Datasheet", and the datasheet's feature list prints "Designed for 3-phase grid connection".
Where: User manual section 8.1 title; datasheet title and Product Features
Printed as "Nominal Output Voltage/Range(1) 380V/324V-468V"; footnote (1) says the nominal voltage and frequency range can be extended beyond nominal if required by the utility.
Where: User manual section 8.1, PDF page 21 (printed page 20), Output Data (AC), Nominal Output Voltage/Range
Printed as "Communication (Inverter To ECU)(4) Encrypted ZigBee"; footnote (4) recommends no more than 80 inverters registered to one ECU for stable communication.
Where: User manual section 8.1, PDF page 21 (printed page 20), Features, Communication (Inverter To ECU)
Printed as "Maximum Continuous Output Power 3200VA" in the user manual and the datasheet; nominal output current is printed as "4.85Ax3". Manufacturer claim, not an independent test.
Where: User manual section 8.1, PDF page 21 (printed page 20), Output Data (AC), Maximum Continuous Output Power; datasheet PDF page 2, same row
IEC 62109-1; IEC 62109-2; IEC 61000-6-1,-2,-3,-4; EN 62109-1; EN 62109-2; EN 61000-6-1; EN 61000-6-3; EN 50549-1
Compliance list as printed in the datasheet (the printed list ends with a semicolon); the user manual's section 8.1 table does not print it. Maker claims; no certificate or listing was checked.
Printed as "Operating Ambient Temperature Range(3) - 40 °C to + 65 °C"; footnote (3) says the inverter may enter a power de-grade mode under poor ventilation and heat dissipation.
Where: User manual section 8.1, PDF page 21 (printed page 20), Mechanical Data, Operating Ambient Temperature Range
Not statedMPPT trackersNot statedMPPT range58 to 85 V
AC output
380 V
Warranty
12 years
Size
Unknown
Evidence score
14/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term12 years14.4 / 30.0
12 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty(5) 12 Years Standard" in the user manual and the datasheet. Footnote (5) says that to be eligible for the warranty, APsystems microinverters need to be monitored via the EMA portal, and refers to the warranty terms on global.APsystems.com, which were not read.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
12 years
Printed as "Warranty(5) 12 Years Standard" in the user manual and the datasheet. Footnote (5) says that to be eligible for the warranty, APsystems microinverters need to be monitored via the EMA portal, and refers to the warranty terms on global.APsystems.com, which were not read.
Where: User manual section 8.1, PDF page 21 (printed page 20), Features, Warranty
Fetched by Research from global.apsystems.com on 2026-10-14 at 08:44:24 UTC with the paced fetcher, which read global.apsystems.com's robots.txt and allowed the path.
Location: Section 8.1 QT2D 3-Phase Microinverter Datasheet, PDF page 21; 4.3.3 Step 3, PDF page 10
Retrieved Oct 14, 2026
APsystems' own user manual "APsystems QT2D 3-Phase Microinverter (For APAC)" (printer's legal entity ALTENERGY POWER SYSTEM Inc.; cover printed "2025/03/10 Rev1.5"). Its section 8.1 "QT2D 3-Phase Microinverter Datasheet" (PDF page 21, printed page 20) has a single QT2D column and is the primary source for this model. Served by APsystems from its own site global.apsystems.com (path /wp-content/uploads/, which global.apsystems.com's robots.txt allows), fetched by Research on October 14, 2026 at 08:44:24 UTC. APsystems' current document pages send their downloads to apsystems.filecloudonline.com, whose robots.txt disallows every path for all agents ("User-agent: *" with "Disallow: /"), so that host is not used; this file is the one APsystems still serves on its allowed site. It is not the newest revision. APsystems' document library now lists a later revision, served only through apsystems.filecloudonline.com, so this earlier revision is the newest one an allowed host serves; a later revision from a host that allows access would replace it. Checked by Research against its printed content, read from the text layer and confirmed on the rendered pages. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by APsystems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Fetched by Research from global.apsystems.com on 2026-10-14 at 08:38:29 UTC with the paced fetcher, which read global.apsystems.com's robots.txt and allowed the path.
Location: PDF page 2, Datasheet | QT2D 3-Phase Microinverter (read on the rendered page); PDF page 1, Product Features
Retrieved Oct 14, 2026
APsystems' own two-page QT2D 3-Phase Microinverter datasheet, printed "2025/03/10 Rev1.3", with a single column for Model QT2D, Region APAC. Its text layer places the model and region headings apart from the table, so its column was read on the rendered page; used beside the user manual, and alone for the rows the manual's table omits (peak power tracking voltage and the compliance list). Served by APsystems from its own site global.apsystems.com (path /wp-content/uploads/, which global.apsystems.com's robots.txt allows), fetched by Research on October 14, 2026 at 08:38:29 UTC. APsystems' current document pages send their downloads to apsystems.filecloudonline.com, whose robots.txt disallows every path for all agents ("User-agent: *" with "Disallow: /"), so that host is not used; this file is the one APsystems still serves on its allowed site. It is not the newest revision. APsystems' document library now lists a later revision, served only through apsystems.filecloudonline.com, so this earlier revision is the newest one an allowed host serves; a later revision from a host that allows access would replace it. Checked by Research against its printed content, read from the text layer and confirmed on the rendered pages. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by APsystems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
APsystems QT2D 3-Phase Microinverter (For APAC) user manual, 2025/03/10 Rev1.5
Archived copy of a document published by APsystems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
APsystems QT2D 3-phase microinverter datasheet, Region APAC, 2025/03/10 Rev1.3
Archived copy of a document published by APsystems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].