Printed as "is designed for single-phase operation only" in the Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 40).
Where: PDF page 40, 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, AC parameters, note 15
No grounding electrode conductor, equipment grounding conductor or grounded conductor (neutral) required; Class II double-insulated with ground fault protection; the AHJ may require bonding the mounting bracket to the racking
Printed as "do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral)." and "The microinverter has a Class II double-insulated rating, including ground fault protection (GFP)." in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 2.2 Grounding considerations.
Where: PDF page 13, section 2.2 Grounding considerations
Printed as "Weight 2.42 lb (1.1 kg)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, Features and specifications, Weight row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 41, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, Features and specifications, Weight row
Printed as "Peak output power VA 384 @ 240 VAC 366 @ 208 VAC" in the Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 40). No duration is printed for this figure.
Where: PDF page 40, 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, AC parameters, "Peak output power" row
Printed as "Total harmonic distortion % <5" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, AC parameters, Total harmonic distortion row.
Where: PDF page 40, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, AC parameters, Total harmonic distortion row
At least 1.9 cm (3/4 in) between the roof and the microinverter and 1.3 cm (1/2 in) between the back of the PV module and the top of the microinverter; for a vertical mount, more than 30 cm (12 in) from the edges of the PV module
Printed as "Allow a minimum of ¾ in (1.9 cm) between the roof and the microinverter. Also, allow ½ in (1.3 cm) between the back of the PV module and the top of the microinverter." and "For a vertical mount, maintain a clearance of >12 in (30 cm) from the edges of the PV module" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 4.3 Mount the microinverters.
Where: PDF page 18, section 4.3 Mount the microinverters
W 175 × H 212 × D 30.2 mm / W 6.89 × H 8.35 × D 1.19 in converted
Printed as "Dimensions (W × H × D) 6.9" × 8.3" × 1.2" (175 mm × 212 mm × 30.2 mm)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, Features and specifications, Dimensions (W × H × D) row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 41, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, Features and specifications, Dimensions (W × H × D) row
Printed as "MPPT voltage range V 29.5–45" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, MPPT voltage range row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 39, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, MPPT voltage range row
60 Hz (nominal); extended frequency range 47-68 Hz
Printed as "Nominal frequency Hz 60 Extended frequency range Hz 47–68" in the Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 40).
Where: PDF page 40, 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, AC parameters, "Nominal frequency" and "Extended frequency range" rows
240 V split-phase (L-L) or 208 V single-phase (L-L)
Printed as "8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications"; "Nominal grid voltage (L-L) V Split-phase (L-L), 180° @ 240 VAC Single-phase (L-L), 120° @ 208 VAC"; "do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral)" in Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 39; PDF page 40; PDF page 13). Revised on 16 October 2026: Owner report 2026-10-16 (inverter filter AC output 120/240 V): the earlier text read as a 120/240 V unit; the manual prints a 240 V (or 208 V) output between the two lines only, with no 120 V output.
Where: PDF page 39; PDF page 40; PDF page 13
Sources
208 V, single-phase (L-L), 120 degrees
The same row prints a 208 VAC single-phase configuration for this SKU.
Printed as "Maximum continuous operating DC A 14" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, Maximum continuous operating DC row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 39, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, Maximum continuous operating DC row
Printed as "Maximum Input DC Voltage V 60" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC voltage row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 39, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC voltage row
AC side protection requires a maximum of 20 A per branch circuit
Printed as "AC side protection requires a maximum of 20 A per branch circuit" in the Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 40).
Where: PDF page 40, 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, "PV array configuration" row
Printed as "Operating Range V 18–58" in the Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 39). DC input operating range.
Where: PDF page 39, 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, "Operating Range" row
0.38 kW*Converted: 384 VA x power factor 1.0 / 1000 = 0.384 kW
Printed as 384 VA maximum continuous output power for the 240 VAC configuration; stored at the power factor setting of 1.0 the same document prints as default.
Under the PV module, horizontally bracket side up or vertically; never upside down
Printed as "The microinverters should be mounted beneath the modules, either horizontally bracketed side up or vertically oriented." and "Do not mount the microinverter upside down." in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 4.3 Mount the microinverters.
Where: PDF page 18, section 4.3 Mount the microinverters
Printed as "Nominal grid voltage (L-L) V Split-phase (L-L), 180° @ 240 VAC" and "Single-phase (L-L), 120° @ 208 VAC15" in the Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 40). Note 15 says the IQ8HC "is designed for single-phase operation only".
Where: PDF page 40, 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, AC parameters, "Nominal grid voltage (L-L)" row
Printed as "Maximum input DC short-circuit current A 25" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC short-circuit current row. This is the microinverter input limit; the maximum module Isc is printed separately.
Where: PDF page 39, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC short-circuit current row
Printed as "Ambient temperature range –40°F to 149°F (–40°C to 65°C)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, Features and specifications, Ambient temperature range row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 41, section 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US Microinverter specifications, Features and specifications, Ambient temperature range row
Not statedMPPT trackersNot statedMPPT range29.5 to 45 V
AC output
240 V split-phase (L-L) or 208 V single-phase (L-L)
Warranty
Not stated
Size
1.12 L* (Calculated from published dimensions)W: 175 × H: 212 × D: 30.2 mm / W: 6.89 × H: 8.35 × D: 1.19 inWeight1.1 kg / 2.4 lb
Evidence score
24/100Missing details55% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
CertificatesUL 1741 SB +9Claimed14.2 / 45.0
Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Research pending, 0 points: Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CA Rule 21 (UL 1741-SA)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
CAN/CSA-C22.2 No. 107.1-01, 330manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
CAN/CSA-C22.3 No. 9manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
FCC Part 15 Class Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
ICES-0003 Class Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
IEEE 1547:2018 (UL 1741-SB 3rd Ed.)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
UL 62109-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
UL 62109-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8HC Microinverter data sheet DSH-00047-10.0, printed for IQ8HC-72-M-DOM-US alongside IQ8HC-72-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
UL 1741 SBauthority listing reportedlisted as of snapshot[5]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8HC-72-M-DOM-US {208V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2025-02-21. A state equipment list entry, not the certification body's own record.
CECauthority listing reportedlisted as of snapshot[5]
Scope
equipment listing
Covered models
IQ8HC-72-M-DOM-US
Limitations
Model IQ8HC-72-M-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8HC-72-M-DOM-US {208V}"; "IQ8HC-72-M-DOM-US {240V}", CEC listing date 2025-02-21. This is an equipment listing, not UL certification or complete-system approval.
Location: PDF pages 39 and 42, specifications sections 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US and 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US
Retrieved Oct 1, 2026
Enphase's own installation and operation manual for the IQ8MC, IQ8AC, IQ8HC and IQ8X Microinverters (North America), captured 1 October 2026 from enphase.com; revision printed as IOM-00108-7.0-EN, September 2026. Its specifications sections name IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US/IQ8HC-72-M-DOM-US and IQ8X-80-M-US/IQ8X-80-M-DOM-US. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Retrieved Sep 27, 2026
Archived copies
Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Enphase IQ8HC Microinverter data sheet
Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026)
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
IQ8HC-72-M-DOM-US
Manufacturer SKU IQ8HC-72-M-DOM-US · US market
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8HC-72-M-DOM-US {208V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2025-02-21. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model IQ8HC-72-M-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8HC-72-M-DOM-US {208V}"; "IQ8HC-72-M-DOM-US {240V}", CEC listing date 2025-02-21. This is an equipment listing, not UL certification or complete-system approval.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.