Enphase IQ8HC Microinverter IQ8HC-72-M-DOM-US
- Brand
- Enphase
- Model
- IQ8HC-72-M-DOM-US
- SKU / part number
- IQ8HC-72-M-DOM-US[1]
- Category
- Inverters

AC output
| Continuous output | 0.38 kW[1]Calculated |
|---|---|
| Peak output | 384 VA @ 240 VAC; 366 VA @ 208 VAC[2] |
| AC configuration | 240 V, split-phase (L-L), 180 degrees[1] |
| AC output voltage | Split-phase (L-L), 180° @ 240 VAC; Single-phase (L-L), 120° @ 208 VAC[2] |
| AC frequency | 60 Hz (nominal); extended frequency range 47-68 Hz[2] |
| Grid pass-through | ? |
| Maximum output per leg | ? |
Battery
| Battery voltage | ? |
|---|---|
| Battery voltage range | 18 to 58 V[2] |
| Maximum charge current | ? |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | ? |
| Compatible batteries / BMS | ? |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | ? |
| Maximum PV voltage (Voc) | 60 V[1, 2] |
| MPPT voltage range | 29.5 to 45 V[1, 2] |
| MPPT trackers | ? |
| String inputs per MPPT | ? |
| PV current per MPPT | 14 A[1, 2] |
| PV short-circuit current | 25 A[2] |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 97.3 %[1] |
|---|---|
| CEC weighted efficiency | 97 %[1] |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | ? |
| Generator input | ? |
| Transfer time | ? |
| Idle consumption | 0.02 W[1]Calculated |
| Parallel units | ? |
Communication and environment
| Communications | ? |
|---|---|
| Operating temperature | -40 to 65 °C[1, 2] |
| Enclosure rating | NEMA Type 6[1] |
| Operating noise | ? |
Mechanical
| Dimensions | 30.2 D × 175 W × 212 H mm[1, 2] |
|---|---|
| Weight | 1.1 kg / 2.43 lb[1, 2] |
Installation (from the manual)
Protection
| AC input breaker | ? |
|---|---|
| AC output breaker | AC side protection requires a maximum of 20 A per branch circuit[2] |
| Battery fuse or breaker | ? |
| PV disconnect | ? |
Clearances and orientation
| Installation clearances | At least 1.9 cm (3/4 in) between the roof and the microinverter and 1.3 cm (1/2 in) between the back of the PV module and the top of the microinverter; for a vertical mount, more than 30 cm (12 in) from the edges of the PV module[2] |
|---|---|
| Mounting orientation | Under the PV module, horizontally bracket side up or vertically; never upside down[2] |
Grounding
| Grounding and neutral-ground bonding | No grounding electrode conductor, equipment grounding conductor or grounded conductor (neutral) required; Class II double-insulated with ground fault protection; the AHJ may require bonding the mounting bracket to the racking[2] |
|---|
Not in the manual: Torque, Conductors, Communication
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.