Victron Energy Isolation Transformer 8000W 230V ITR000802002

By Victron EnergySKU ITR000802002

No reviews · Write the first

Key specs

Units
SKU
ITR000802002
Official product page
Sources

Victron's product feed on the isolation transformers page names article ITR000802002 "Isolation Transformer 8000W 230V". The feed is embedded page data, so it is checked as markup (expect_html), not as visible text.

Official product page: Isolation transformers product page (article list and specifications) (October 11, 2026 capture) Checked · Earlier document

Location: Isolation transformers page, embedded product feed, article ITR000802002

Documented

Grounding (manual)
M6 chassis earth bolt underneath the enclosure to the vessel ground
Official instruction manual
Sources

Printed as "Connect the M6 bolt underneath the enclosure to the vessel ground." in Victron Energy's Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) (PDF page 7). The manual applies to this model: Manual is for the Isolation Transformer 8000W 230V; dimension drawing names ITR000802002.

Official instruction manual: Victron Energy: Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) Checked · Earlier document

Location: PDF page 7

Documented

Weight
28.17 kg62.1 lb converted
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Weight 12.1 kg 22.2 kg 21.8 kg 28.17 kg". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Weight row

Documented

AC frequency
50/60
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Frequency row

Documented

Input voltage
230 V
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Input 115 or 230 V 115 or 230 V 115 / 230 V Automatic 115/230 V switching 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Input row

Documented

Current rating
35 A
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Rating 22 / 11 A 38 / 19 A 38 / 19 A 35 A". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Rating row

Documented

Enclosure
IP21
Official datasheet
Sources

Printed once for all models as "Protection category: IP 21".

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Enclosure, Common Characteristics

Documented

Output voltage
230 V
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Output row

Documented

AC output breaker (manual)
GFCI in the AC output (output neutral linked to earth)
Official instruction manual
Sources

Printed as "A GFCI must be installed in the AC output of the isolation transformer." in Victron Energy's Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) (PDF page 7). The manual applies to this model: Manual is for the Isolation Transformer 8000W 230V; dimension drawing names ITR000802002.

Official instruction manual: Victron Energy: Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) Checked · Earlier document

Location: PDF page 7

Documented

All specs8
Grounding (manual)
M6 chassis earth bolt underneath the enclosure to the vessel ground
Official instruction manual
Sources

Printed as "Connect the M6 bolt underneath the enclosure to the vessel ground." in Victron Energy's Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) (PDF page 7). The manual applies to this model: Manual is for the Isolation Transformer 8000W 230V; dimension drawing names ITR000802002.

Official instruction manual: Victron Energy: Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) Checked · Earlier document

Location: PDF page 7

Documented

Weight
28.17 kg62.1 lb converted
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Weight 12.1 kg 22.2 kg 21.8 kg 28.17 kg". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Weight row

Documented

AC frequency
50/60
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Frequency row

Documented

Input voltage
230 V
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Input 115 or 230 V 115 or 230 V 115 / 230 V Automatic 115/230 V switching 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Input row

Documented

Current rating
35 A
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Rating 22 / 11 A 38 / 19 A 38 / 19 A 35 A". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Rating row

Documented

Enclosure
IP21
Official datasheet
Sources

Printed once for all models as "Protection category: IP 21".

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Enclosure, Common Characteristics

Documented

Output voltage
230 V
Official datasheet
Sources

Printed in the fourth ("8000 Watt") column of the row "Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Official datasheet: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture) Checked · Earlier document

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Output row

Documented

AC output breaker (manual)
GFCI in the AC output (output neutral linked to earth)
Official instruction manual
Sources

Printed as "A GFCI must be installed in the AC output of the isolation transformer." in Victron Energy's Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) (PDF page 7). The manual applies to this model: Manual is for the Isolation Transformer 8000W 230V; dimension drawing names ITR000802002.

Official instruction manual: Victron Energy: Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026) Checked · Earlier document

Location: PDF page 7

Documented

Published claims and calculations, not independent test results.

Documents

3 on file
  • PDF
    Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture)OfficialVictron EnergyOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-11.

    Location: Specifications

    Retrieved

    Victron Energy's own isolation Transformers 2500 W, 4500 W, 8000 W datasheet, captured October 11, 2026 with the paced research fetcher. Manufacturer statements as printed, not independent tests.

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.63 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-Isolation-Transformers-2500,-4500,-8000-EN-.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 3daa41b4f169020c852f2491e0a7e060a79131d8edf23dbd18d9201056e2b2b1

    Open
  • PDF
    Victron Energy: Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026)OfficialVictron EnergyOfficial instruction manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-15.

    Location: Installation instructions

    Retrieved

    Victron Energy's own manual, captured October 15, 2026 with the paced research fetcher (robots.txt read first). Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 2.50 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Isolation_Transformer_8000W/108939-Isolation_transformers-pdf-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    12
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: df2228d6cadf1b285c8d407d7c8ca9d37b2ede59695394c8fa6610458b10ba3d

    Open
  • WEB
    Isolation transformers product page (article list and specifications) (October 11, 2026 capture)OfficialVictron EnergyOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-11.

    Location: Specifications

    Retrieved

    Victron Energy's own isolation transformers product page (article list and specifications), captured October 11, 2026 with the paced research fetcher. Manufacturer statements as printed, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture)

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.63 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Datasheet-Isolation-Transformers-2500,-4500,-8000-EN-.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3daa41b4f169020c852f2491e0a7e060a79131d8edf23dbd18d9201056e2b2b1

Victron Energy: Isolation Transformer 8000W 230V manual (Rev 00 - 01/2026)

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 2.50 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Isolation_Transformer_8000W/108939-Isolation_transformers-pdf-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
12
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: df2228d6cadf1b285c8d407d7c8ca9d37b2ede59695394c8fa6610458b10ba3d

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

This category has no Evidence score.

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
ITR000802002

Manufacturer SKU ITR000802002 · Global market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.