No product photos yet.
Fox ESS CQ 80.35 Battery System
No sellers found.
Key specs
Units- Nominal voltage
- 256 VOfficial user manual
Sources
Own named model row; transcribed, not calculated from CQ16 module voltage.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 14, Nominal voltage (V); exact CQ 80.35 table
Documented
- Fire protection
- PDF page 11: Despite the extremely stable chemical properties of lithium iron phosphate batteries and the multiple protections, each battery unit is equipped with a fire protection module to further ensure the safety and reliability of Fox ESS batteries. This innovative module utilizes a new type of aerosol fire extinguishing device with features such as pressure-free storage, no maintenance required, high extinguishing efficiency, non-toxic and harmless characteristics.; PDF page 11: The fire extinguishing mechanism of thermal aerosols involves two main mechanisms: the cooling effect from endothermic decomposition and the chemical suppression effects in both gas and solid phases, which work synergistically. Additionally, the gaseous components in the products of the aerosol extinguishing agent also play a supportive role.; PDF page 12: Activation method: Thermal activation Thermal activation temperature: ≥ 170°C Discharge time: ≤ 5 seconds Notes: Please contact Fox ESS for immediate replacement if the fire protection module is activated. Non-professionals should not disassemble the battery without authorization. Do not touch the device until the casing has cooled after the internal fire extinguisher has been activated to prevent burns. For further assistance, please contact an authorized personnel or Fox ESS for further instructions.Official user manual
Sources
Each battery-unit factory aerosol device claim and its own ≥170°C activation/≤5 seconds discharge table. These are extinguisher-device quantities, not battery operating or current limits. Manufacturer statements, not independent suppression validation.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 11, 12
Documented
- Expansion requirements
- PDF page 33: If a battery is replaced or added for energy, each battery’s SOC should be consistent. The max. SOC difference should be between ±5%. If users want to increase their battery system energy, please ensure that the SOC of the existing battery system is about 50%. The manufacturer date of the new battery shall not exceed 12 months; in case of exceeding 12 months. please charge the new battery to around 50%. Note: After installing a new battery, the SOC of battery system may fluctuate or jump unexpectedly. This can be automatically corrected within 1 to 2 weeks via passive balancing.Official user manual
Sources
Full battery expansion SOC/date/passive-balancing passage, not a universal age limit or independently measured balancing result.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 33
Documented
- Grounding (manual)
- PDF page 8: Please ensure that all the batteries are grounded properly.; PDF page 23: The upper and lower two battery packs are fixed with fixed grounding metals (Item E).; PDF page 23: Connect the fixed grounding metals (Item E) between all the batteries.; PDF page 23: The back of the battery also needs to be fixed.A total of four fixed grounding metals (Item E) are required between every two battery packs for fixation.; PDF page 23: The fixed grounding metals have the function of grounding connection. Please connect all the fixed grounding metals.; PDF page 26: Route communication cable (Item J) through right-side cable duct. Step 2 Route grounding cable (Item I) through right-side cable duct and secure with screw. Ensure firm and reliable connection. Step 3 Secure wiring cable with cable ties (Item C). Step 4 Reinstall decorative cover.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Fixed grounding metals E have both fastening and grounding function. External PE screw torque and neutral-earth bonding are not specified; the metal-fastening torque stays separately scoped.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 8, 23, 26
Documented
- Installation clearances (manual)
- PDF page 20, general prose: To ensure proper operation and long battery life, please make sure to leave at least 300mm of cooling space around the battery. Shading or insufficient space for heat dissipation will result in high battery temperatures, which may cause unplanned shutdowns and significantly shorten the service life of the battery.; PDF page 20, single-cluster 3D illustration: ≥50mm arrows, ≥300mm arrows (including top), 50mm between bases. Other direction labels are not invented.; PDF page 20, labeled three-cluster plan: Battery back clearance ≥300mm; Battery side clearance ≥300mm; Clearance between battery clusters ≥300mm; Battery front clearance ≥800mm; between bases 50mm.Official user manualManual prints separate clearance contexts
General cooling prose says at least 300mm around. Single-cluster 3D arrows include ≥50mm and ≥300mm. The labeled three-cluster plan prints front ≥800mm, with back/side/between-cluster ≥300mm and base spacing 50mm. No universal reconciled clearance is selected.
Sources
Assembled CQ16 plus High-Voltage Control Box system. Keep all diagram/configuration contexts. General around-battery cooling prose and labeled plan dimensions are not reconciled into one clearance.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 20, prose and separate single-/three-cluster figures
Documented
- Low SOC storage
- PDF page 33: After the product is powered off, static power consumption and self-discharge loss may occur in internal modules. Therefore, charge batteries in a timely manner and do not store the product in low SOC. Otherwise, the product may be damaged due to overdischarge, and battery modules need to be replaced. Storage in low SOC may occur in the following scenarios:; PDF page 34: The DC Switch on the power control module is OFF. The power cables or signal cables are not connected. The batteries cannot be charged due to a system fault after discharge. The batteries cannot be charged due to incorrect configurations in the system. The batteries cannot be charged due to no PV input and long-term mains failure. Regardless of scenarios, the batteries must be charged within the longest interval corresponding to the SOC when the batteries are powered off. If the batteries are not charged within the specified interval, they may be damaged due to overdischarge. Storage environment temperature Power-Off SOC Before Storage Maximum Charge Interval 0~35°C 0% ≤ SOC < 5% 7 days Note: When the battery SOC decreases to 0%, charge the batteries within seven days. Permanent battery faults caused by delayed charge due to customer reasons are beyond the warranty scope.Official user manual
Sources
Battery-module conditions: table 0~35°C, 0%≤SOC<5%, maximum 7 days. The separate 0%-within-seven-days and delayed-charge warranty note remain complete; no extrapolation is made.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 33, 34
Documented
- Storage schedule
- Storage environment temperature / Relative humidity of storage environment / Storage time / SOC; Below -20°C / / / Not allowed / /; -20~0°C / 10%~90% / ≤1 months / 20%≤SOC≤50%; 0~35°C / 10%~90% / ≤6 months / 20%≤SOC≤50%; 35~55°C / 10%~90% / ≤1 months / 20%≤SOC≤50%; Above55°C / / / Not allowed / /Official user manual
Sources
Battery storage duration, humidity and SOC table as printed. Shared 0/35°C endpoints are not reinterpreted; no single unqualified storage envelope replaces it.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 33, storage time/RH/SOC table
Documented
- Cable bending radius / connector notes (manual)
- R≥6×DOfficial user manual
Sources
Printed diagram relation R≥6×D, external controller-to-inverter cable only. D/D' definitions and an absolute radius are not inferred. Separate diagram vertical ≥30cm, angle ≥90° and strict prose >30cm remain together in the connection field.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 27
Documented
20 specs not documented yet: chemistry, nominal energy, usable energy, rated capacity, maximum discharge current, maximum charge current, operating voltage range, cycle rating, battery weight, dimensions, enclosure rating, address / dip setting, conductor sizes, nominal capacity, communication terminal torque, depth of discharge, ground terminal torque, mounting hole dimensions, external fuse breaker rating, manufacturer fire instructionsHelp fill in ›
All specs44
- Chemistry
- Not documented
Details
The named partial table has no chemistry row. No chemistry scalar is transferred from CQ16 or the CQ 241.05 full-system table.
Not documented
- Nominal energy
- Not documented
Details
This named row prints Rated energy, not a separate Nominal energy claim.
Not documented
- Usable energy
- Not documented
Details
No usable energy is printed for this named system row; no DoD multiplication.
Not documented
- Nominal voltage
- 256 VOfficial user manual
Sources
Own named model row; transcribed, not calculated from CQ16 module voltage.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 14, Nominal voltage (V); exact CQ 80.35 table
Documented
- Rated capacity
- Not documented
Details
No rated Ah capacity is printed for this named system row.
Not documented
- Maximum discharge current
- Not documented
Details
No discharge-current scalar is printed for this named row.
Not documented
- Maximum charge current
- Not documented
Details
No charge-current scalar is printed for this named row; module/controller/full-system current is not transferred.
Not documented
- Operating voltage range
- Not documented
Details
No operating voltage range is printed for this named system; no module-series arithmetic or CQ 241.05 transfer.
Not documented
- Cycle rating
- Not documented
Details
No cycle-life row for this named system; CQ 241.05 claim is not transferred.
Not documented
Lifetime production
Published claims and calculations are not independently tested lifetime output.
- Battery weight
- Not documented
Details
No whole-system weight is printed for this named row; no component sum or CQ 241.05 transfer.
Not documented
- Dimensions
- Not documented
Details
No whole-system dimensions are printed for this named row; no stack arithmetic or CQ 241.05 transfer.
Not documented
- Enclosure rating
- Not documented
Details
No whole-system ingress rating is printed in this named row; module or CQ 241.05 ratings are not transferred.
Not documented
- Fire protection
- PDF page 11: Despite the extremely stable chemical properties of lithium iron phosphate batteries and the multiple protections, each battery unit is equipped with a fire protection module to further ensure the safety and reliability of Fox ESS batteries. This innovative module utilizes a new type of aerosol fire extinguishing device with features such as pressure-free storage, no maintenance required, high extinguishing efficiency, non-toxic and harmless characteristics.; PDF page 11: The fire extinguishing mechanism of thermal aerosols involves two main mechanisms: the cooling effect from endothermic decomposition and the chemical suppression effects in both gas and solid phases, which work synergistically. Additionally, the gaseous components in the products of the aerosol extinguishing agent also play a supportive role.; PDF page 12: Activation method: Thermal activation Thermal activation temperature: ≥ 170°C Discharge time: ≤ 5 seconds Notes: Please contact Fox ESS for immediate replacement if the fire protection module is activated. Non-professionals should not disassemble the battery without authorization. Do not touch the device until the casing has cooled after the internal fire extinguisher has been activated to prevent burns. For further assistance, please contact an authorized personnel or Fox ESS for further instructions.Official user manual
Sources
Each battery-unit factory aerosol device claim and its own ≥170°C activation/≤5 seconds discharge table. These are extinguisher-device quantities, not battery operating or current limits. Manufacturer statements, not independent suppression validation.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 11, 12
Documented
- Expansion requirements
- PDF page 33: If a battery is replaced or added for energy, each battery’s SOC should be consistent. The max. SOC difference should be between ±5%. If users want to increase their battery system energy, please ensure that the SOC of the existing battery system is about 50%. The manufacturer date of the new battery shall not exceed 12 months; in case of exceeding 12 months. please charge the new battery to around 50%. Note: After installing a new battery, the SOC of battery system may fluctuate or jump unexpectedly. This can be automatically corrected within 1 to 2 weeks via passive balancing.Official user manual
Sources
Full battery expansion SOC/date/passive-balancing passage, not a universal age limit or independently measured balancing result.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 33
Documented
- Grounding (manual)
- PDF page 8: Please ensure that all the batteries are grounded properly.; PDF page 23: The upper and lower two battery packs are fixed with fixed grounding metals (Item E).; PDF page 23: Connect the fixed grounding metals (Item E) between all the batteries.; PDF page 23: The back of the battery also needs to be fixed.A total of four fixed grounding metals (Item E) are required between every two battery packs for fixation.; PDF page 23: The fixed grounding metals have the function of grounding connection. Please connect all the fixed grounding metals.; PDF page 26: Route communication cable (Item J) through right-side cable duct. Step 2 Route grounding cable (Item I) through right-side cable duct and secure with screw. Ensure firm and reliable connection. Step 3 Secure wiring cable with cable ties (Item C). Step 4 Reinstall decorative cover.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Fixed grounding metals E have both fastening and grounding function. External PE screw torque and neutral-earth bonding are not specified; the metal-fastening torque stays separately scoped.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 8, 23, 26
Documented
- Installation clearances (manual)
- PDF page 20, general prose: To ensure proper operation and long battery life, please make sure to leave at least 300mm of cooling space around the battery. Shading or insufficient space for heat dissipation will result in high battery temperatures, which may cause unplanned shutdowns and significantly shorten the service life of the battery.; PDF page 20, single-cluster 3D illustration: ≥50mm arrows, ≥300mm arrows (including top), 50mm between bases. Other direction labels are not invented.; PDF page 20, labeled three-cluster plan: Battery back clearance ≥300mm; Battery side clearance ≥300mm; Clearance between battery clusters ≥300mm; Battery front clearance ≥800mm; between bases 50mm.Official user manualManual prints separate clearance contexts
General cooling prose says at least 300mm around. Single-cluster 3D arrows include ≥50mm and ≥300mm. The labeled three-cluster plan prints front ≥800mm, with back/side/between-cluster ≥300mm and base spacing 50mm. No universal reconciled clearance is selected.
Sources
Assembled CQ16 plus High-Voltage Control Box system. Keep all diagram/configuration contexts. General around-battery cooling prose and labeled plan dimensions are not reconciled into one clearance.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 20, prose and separate single-/three-cluster figures
Documented
- Address / DIP setting
- Not documented
Details
The Module addressing failed indication does not provide a numeric address or DIP-switch setting.
Location: PDF page 31, fault labels
Not documented
- Conductor sizes
- Not documented
Details
No AWG or mm² conductor cross-section is printed. Cable counts, tool sizes and pin labels are separate quantities.
Location: Reviewed CQ16 manual, PDF pages 1-37
Not documented
- Low SOC storage
- PDF page 33: After the product is powered off, static power consumption and self-discharge loss may occur in internal modules. Therefore, charge batteries in a timely manner and do not store the product in low SOC. Otherwise, the product may be damaged due to overdischarge, and battery modules need to be replaced. Storage in low SOC may occur in the following scenarios:; PDF page 34: The DC Switch on the power control module is OFF. The power cables or signal cables are not connected. The batteries cannot be charged due to a system fault after discharge. The batteries cannot be charged due to incorrect configurations in the system. The batteries cannot be charged due to no PV input and long-term mains failure. Regardless of scenarios, the batteries must be charged within the longest interval corresponding to the SOC when the batteries are powered off. If the batteries are not charged within the specified interval, they may be damaged due to overdischarge. Storage environment temperature Power-Off SOC Before Storage Maximum Charge Interval 0~35°C 0% ≤ SOC < 5% 7 days Note: When the battery SOC decreases to 0%, charge the batteries within seven days. Permanent battery faults caused by delayed charge due to customer reasons are beyond the warranty scope.Official user manual
Sources
Battery-module conditions: table 0~35°C, 0%≤SOC<5%, maximum 7 days. The separate 0%-within-seven-days and delayed-charge warranty note remain complete; no extrapolation is made.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 33, 34
Documented
- Storage schedule
- Storage environment temperature / Relative humidity of storage environment / Storage time / SOC; Below -20°C / / / Not allowed / /; -20~0°C / 10%~90% / ≤1 months / 20%≤SOC≤50%; 0~35°C / 10%~90% / ≤6 months / 20%≤SOC≤50%; 35~55°C / 10%~90% / ≤1 months / 20%≤SOC≤50%; Above55°C / / / Not allowed / /Official user manual
Sources
Battery storage duration, humidity and SOC table as printed. Shared 0/35°C endpoints are not reinterpreted; no single unqualified storage envelope replaces it.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 33, storage time/RH/SOC table
Documented
- Cable bending radius / connector notes (manual)
- R≥6×DOfficial user manual
Sources
Printed diagram relation R≥6×D, external controller-to-inverter cable only. D/D' definitions and an absolute radius are not inferred. Separate diagram vertical ≥30cm, angle ≥90° and strict prose >30cm remain together in the connection field.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 27
Documented
- Site requirements
- PDF page 5: This manual is designed for qualified personnel only. The tasks described in this document should be performed by authorized and qualified technicians only.; PDF page 5: After Installation the Installer must explain the user manual to the end user.; PDF page 5: This manual is intended for use by qualified electricians only. All procedures described herein shall be performed by trained and experienced electrical personnel in compliance with basic electrical safety requirements.; PDF page 7: All operations, including transportation, installation, start-up and maintenance, must be performed by qualified and trained personnel.; PDF page 7: Do not energize the equipment without completing the installation or without professional confirmation, and strictly prohibit operation with electricity.; PDF page 7: Always use special insulated tools for wiring operations. Direct contact or contact with other conductors or indirect contact with the power supply equipment through wet objects is prohibited.; PDF page 7: During operation of the equipment, the enclosure temperature is high and there is a risk of burns. Before touching any part of the inverter, make sure that the equipment and its surfaces are at a contact-safe temperature and voltage before proceeding.; PDF page 8: Make sure that the inverter and battery is completely turned off before commencing installation.; PDF page 7: Do not expose battery to open flame.; PDF page 7: Store in a cool and dry place with ample ventilation.; PDF page 7: Do not store the product near water sources.; PDF page 7: Store the product on a flat surface.; PDF page 7: Recommend to store the product out of reach of children and animals.; PDF page 7: Do not damage the unit by dropping, deforming, impacting, cutting or penetrating with a sharp object. It may cause leakage of electrolyte or fire.; PDF page 7: Do not touch any liquid spilled from the product. There is a risk of electric shock or damage to skin.; PDF page 7: Always handle the battery wearing the insulated gloves.; PDF page 7: Do not step on the product or place any foreign objects on it. This can result in damage.; PDF page 7: Do not charge or discharge damaged battery.; PDF page 8: Warning: Do not use the battery if it has been dropped or appears compromised.; PDF page 9: Make sure the installation site meets the following conditions: Ensure the installation area is protected from direct sunlight, rain, and snow accumul ation, a shelter (e.g., rain canopy) is recommended. Keep the installation area away from high-temperature sources, flammable or explos ive materials, and other potential explosion hazards such as gas valves, LPG cylind ers, heat pumps, firewood stacks, etc. The installation area must be completely waterproof, with a hard, level floor, and the wall should not have noticeable inclined angle. Maintain low and stable humidity with good ventilation; dust and dirt within the install ation area must be minimized. Position the installation area away from television antennas or antenna cables to avo id lightning strikes and electromagnetic interference. Avoid the presence of flammable debris around the battery, such as cotton, fabric, ha ystacks, etc., which may be ignited by sparks and then lead the fire source to the battery, thus causing the battery to burn. Avoid the presence of hot or flammable objects around the battery, such as hydraulic bottles (natural gas, oxygen, etc.), heat pumps and so on.; PDF page 8: Do not install the equipment outdoors in salt-affected areas because it may be corroded. A salt-affected area refers to the region within 1000 m of the coast or prone to sea breeze.; PDF page 8: Please refrain from installing the battery near any water source to prevent accidental submersion.; PDF page 8: Recommend to install the battery away from children or pets.; PDF page 8: Do not use battery in high static environment where the protection device might be damaged.; PDF page 6: CE mark. The product complies with the relevant EU directives.; PDF page 6: Danger of high voltages. Danger to life due to high voltages in the inverter!; PDF page 6: Do not place nor install near flammable or explosive materials.; PDF page 6: Install the product out of reach of children.; PDF page 6: Prohibit the use of water to extinguish fires.; PDF page 6: Prohibition of private maintenance.; PDF page 6: Prohibit Connector Reversal.; PDF page 6: Read the manual before performing any operations on the inverter.; PDF page 6: Do not dispose of the product with household wastes.; PDF page 6: Disconnect the equipment before carrying out maintenance or repair.; PDF page 6: Observe precautions for handling electrostatic discharge sensitive devices.; PDF page 6: PE conductor terminal.; PDF page 6: Caution, risk of electric shock, energy storage timed discharge.; PDF page 21: 6mm Magnetic Phillips Screwdriver; PDF page 21: Crimpers; PDF page 21: Safety Shoes; PDF page 21: Multimeter; PDF page 21: Safety Gloves; PDF page 21: Safety Glasses; PDF page 21: Plier; PDF page 21: Cable Ties; PDF page 21: Hammer Drill @φ8mm; PDF page 21: Spirit Level; PDF page 21: Tape; PDF page 21: Marker; PDF page 24: Depending on the actual installation requirements, you can selectively remove the "Removable".; PDF page 25: Install the decorative covers of CQ16 and High-Voltage Control Box.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Source passages retain qualified-personnel, weather, handling and safety-symbol contexts. Printed CE is not independent certification or regional-sale proof. Some original safety rows say inverter, without reclassifying this product.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 5, 6, 7, 8, 9, 21, 24, 25
Documented
- Battery energy
- 80.35 kWhRated energy 80.35 kWh, as printed.Official user manual
Sources
The manufacturer row says Rated energy, not Nominal energy. Existing generic Battery energy field preserves the printed quantity without a renamed nominal claim.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 14, Rated energy (kWh); exact CQ 80.35 table
Documented
- Battery fuse or breaker (manual)
- PDF page 16: Battery protection: Internal Short Circuit, Over Voltage, Over Current, Over Temp, Under Voltage.; PDF page 34: The battery system includes an automatic low-temperature protection feature. it proactively manages. The battery to maintain adequate charge, extending standby time when temperatures drop.; PDF page 35: The CQ battery system has a non-reset table function to stop operation when one or more cells in the battery system deviate from the operating region during operation. This feature shall not be a user reset table or allow for automatic reset. Please ask after sales for help.; PDF page 31: Under voltage fault; PDF page 31: Over voltage fault; PDF page 31: Over temperature fault; PDF page 31: Under temperature fault; PDF page 31: Discharge over current; PDF page 31: Charge over current; PDF page 31: Pre-Charge failed; PDF page 31: AFE communication failed; PDF page 31: Module addressing failed; PDF page 31: BMU communication failed; PDF page 31: PCS communication failed; PDF page 31: HVB FUSE fault; PDF page 31: Module FUSE fault; PDF page 31: Power failed; PDF page 31: Internal total voltage sampling failed; PDF page 31: Temperature sampling failed; PDF page 31: Relay adhesion; PDF page 31: Relay not close; PDF page 31: Relay drive failed; PDF page 31: Single cell "0V" fault; PDF page 31: Temperature high permanent failed; PDF page 31: The single voltage high permanently failed; PDF page 31: SOH low protection; PDF page 31: AFE failed(UV/OV/UT/OT); PDF page 31: Shutdown failure; PDF page 31: Other faultOfficial user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Printed connected-system protection/reserve/lock context. Fault labels and LED legend are not fuse ratings, address settings or a reset procedure. No low-temperature reserve SOC, duration or warming hardware is inferred. The complete symbol-coded LED legend and fault matrix remain in the cited manual, PDF page 31; they are not transcribed as structured specifications.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 16, 31, 34, 35
Documented
- Operating sequence
- PDF page 28: When the grid connected system is started, the inverter should be turned on first to avoid the current pulse of the inverter increasing to the battery pack. All installation and operation must comply with local electrical standards. Check all power cables and communication cables carefully. System Start Up: When the inverter is connected to the PV and the grid and both are operating normally, turn on the battery DC Switch. Press the Power switch and hold it for 3 seconds, then release. The Status LED is blinking green and indicates that the system is working normally. System Shut Down: Press and hold the Power Switch for at least 5 seconds until all of the LEDs (BMS Status LED and SOC LED) begin blinking. Once they start blinking, release the switch. The lights will automatically turn off after 5 seconds. Then, turn off the DC Switch. System Black Start: Under special circumstances when both PV and Grid power are out of order, the battery can be activated through the "Black Start" function. This means that our energy storage inverter and battery can continue to operate. The startup steps for Black Start are as follows: Turn on the DC Switch, press and hold the Power Switch for 3 seconds, then release. Press the Power Switch three times in succession within 4 seconds (Complete within 30 seconds after the battery system starts up). The Status LED remains solid green, indicating successful activation of Black Start mode. Note: Ensure correct battery-inverter connection prior to Black Start. No cable modifications during Black Start.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Full startup, shutdown and black-start passages. POWER/DC controls are on the High-Voltage Control Box; these are connected-system sequences, not standalone module switches or a universal inverter compatibility claim.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 28
Documented
- Terminal torque (manual)
- 3 to 4 N·mOfficial user manual
Sources
Internal assembled cable/copperbar F/N/V/Q fastening only, labeled M5/6. External P+/P− and PE connections have no printed torque.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 23, Step 4 Item K fastening
Documented
- Communication ports (manual)
- PDF page 17: High-Voltage Control Box interface: BAT-: BAT negative terminal; PDF page 17: High-Voltage Control Box interface: DC Switch: Power switch, battery charge and discharge circuit switch; PDF page 17: High-Voltage Control Box interface: BAT+: BAT positive terminal; PDF page 17: High-Voltage Control Box interface: Power Switch: Battery charge and discharge circuit switch; PDF page 17: High-Voltage Control Box interface: Status LED / SOC LED: LED display specific alarm information and battery system power; PDF page 17: High-Voltage Control Box interface: COM: Communication interface with the battery pack; PDF page 17: High-Voltage Control Box interface: Handle: DC Switch Handle; PDF page 17: High-Voltage Control Box interface: CAN: Battery and inverter communication port; PDF page 17: High-Voltage Control Box interface: P-: High-Voltage Control Box negative terminal, connected to hybrid inverter's negative terminal; PDF page 17: High-Voltage Control Box interface: PE: Ground terminal, connected to the hybrid inverter; PDF page 17: High-Voltage Control Box interface: P+: High-Voltage Control Box positive terminal, connected to hybrid inverter's positive terminal; PDF page 24: Use communication cable(Item O)to connect the first battery "INCOM (white)" from the high-voltage box "OUTCOM (yellow)". The communication cable (Item O, U) between other battery packs are connected in sequence from "OUTCOM" to "INCOM". (Refer to the illustration below: Following the direction indicated by the arrows, insert the communication cables harness in the color sequence “yellow, white, yellow, white...”.) ② Use cable ties (Item C) to fix the cable. Note: When connecting cables, observe the installation diagram and pay attention to the direction of the communication cables. Otherwise, the products may not work properly. All wiring harnesses and brads supplied by FOX.; PDF page 27: High-Voltage Control Box external CAN pinout, PIN / Function Definitions: 1 A-START; 2 GND; 3 /; 4 BMS-CANL; 5 BMS-CANH; 6 BMS-CANH; 7 BMS-CANL; 8 /.; PDF page 30: High-Voltage Control Box: Status LED*1; SOC LED*4. The labels remain separate, with no summed total.; PDF page 30: SOC indication tables and native color/symbol layout are retained in the manual on PDF page 30; no unverified flattened symbol-to-color mapping is assigned.; PDF page 17: CQ16 module interface: BAT-: BAT negative terminal; PDF page 17: CQ16 module interface: BAT+: BAT positive terminal; PDF page 17: CQ16 module interface: Fan: Ventilation and heat dissipation; PDF page 17: CQ16 module interface: COM1: Connection position of battery module communication and power supply input; PDF page 17: CQ16 module interface: COM2: Connection position of battery module communication and power supply output; PDF page 17: CQ16 module interface: LED: Battery pack status display; PDF page 29: For CQ 16 Green LED Red LED Batteries Status On for 0.5s, Off for 0.5s On for 0.5s, Off for 0.5s Running in boot On for 0.1s, Off for 0.1s On for 0.1s, Off for 0.1s Upgrading On for 1s, Off for 1s Off Normal Working Off On for 1s, Off for 1s AlarmOfficial user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Controller external CAN pinout is separate from module COM1/COM2 ports. Status LED*1 and SOC LED*4 stay separate labels without a summed count. Native SOC symbol/color layout is retained in the cited document, not reconstructed from flattened text.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 17, 24, 27, 29, 30
Documented
- Included components
- High-Voltage Control Box*1+CQ16*5Official user manual
Sources
Printed configuration composition only, not sale pack quantity, a synthesized bundle SKU or totals calculated from component figures.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 14, Composition; exact CQ 80.35 table
Documented
- Nominal capacity
- Not documented
Details
No Ah capacity is printed for this named system row; no energy/voltage calculation.
Not documented
- Communication terminal torque
- Not documented
Details
No communication-connector torque is printed in the reviewed manual.
Location: Reviewed CQ16 manual, PDF pages 1-37
Not documented
- Maintenance schedule
- PDF page 33: Regularly check whether the service environment of the battery meets the requirements, and the installation position should be far away from the heat source.; PDF page 33: Regularly check whether the battery and its supporting terminals, connecting cables and indicator lights are normal.; PDF page 34: When the red / green LED on the panel is flashing or normally on, it does not mean that the CQ16 is abnormal, it may be just an alarm or protection. Please check the “LED status indicators” in chapter 9 for the detailed faulty definition before any troubleshooting steps. In general, the alarm indication is normal without manual intervention. When the alarm triggering state is removed, CQ16 will automatically return to normal use. Problem determination based on the following points: Check if the red indicator light illuminates once the battery enters operation; Whether the buzzer in High-Voltage Control Box on; Whether the battery system can be communicated with inverter; Whether the battery can be output voltage or not. Preliminary determination steps Battery system cannot work, when DC Switch on and POWER on, the LED doesn’t light up or flash, please contact the local distributor. The LED display of High-Voltage Control Box and CQ16 is normal, but it cannot charge and discharge. Observe the display screen of inverter and there is no SOC. Please check whether the CAN communication between High-Voltage Control Box to inverter is well connected. If the connection is good, please replace a CAN communication cable. If the SOC is still not visible on the inverter display screen,; PDF page 35: please contact the local distributor. After the battery system is powered on, if you can see the alarm information on the LED and inverter display screen at the same time, please contact the local distributor.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Regular checks and complete preliminary troubleshooting text; no fixed maintenance interval is invented. The manual chapter 9 cross-reference stays as printed. No user reset, firmware update procedure or model compatibility is inferred.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 33, 34, 35
Documented
- Mounting orientation (manual)
- PDF page 21: Position the base (Item R) on the floor at the distance shown in the figure below, and verify levelness using a spirit level.; PDF page 21: When placing the base, it is necessary to ensure that the distance between the bases is 50mm; Otherwise, the base-fixed metals (Item T) in Step 2 will not be able to be installed.; PDF page 22: Two methods are available for handling the battery pack: Method 1: Screw the solid handles (Item S) from the Accessory Package into the pre- tapped mounting holes on the battery pack. Method 2: Use the integral handle slots molded into the battery pack housing.; PDF page 22: By moving the position of the battery pack, the raised sphere on the base will bounce up and restrict the movement of the battery pack.; PDF page 22: Use front fixed sheet metals (Item P) to secure the battery pack and the base. Fix the battery packs at the bottom of the two columns using base-fixed metals (Item T).; PDF page 23: Select the appropriate stacking configuration based on the quantity of battery packs, then handle and stack the High-Voltage Control Box and all CQ16 in accordance with the selected arrangement. ② The upper and lower two battery packs are fixed with fixed grounding metals (Item E). ③ Connect the fixed grounding metals (Item E) between all the batteries. Note: Position the High-Voltage Control Box on the top of the battery packs in the rightmost column. The back of the battery also needs to be fixed.A total of four fixed grounding metals (Item E) are required between every two battery packs for fixation. The fixed grounding metals have the function of grounding connection. Please connect all the fixed grounding metals.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Floor-base and stacking procedures as printed. Controller position is top of the rightmost column. No permission for an unprinted mounting orientation is inferred.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 21, 22, 23
Documented
- Depth of discharge
- Not documented
Details
No DoD rating is printed for this named system; module or cycle-test figures are not transferred.
Not documented
- Ground terminal torque
- Not documented
Details
No numerical external PE grounding-screw torque is printed. Fixed grounding-metal E/K fastening is a separate assembly quantity.
Location: PDF pages 23 and 26
Not documented
- Mounting fastener torque
- 3 to 4 N·mOfficial user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Literal M5/6, 3~4N·m for shown base P/T/K and fixed-grounding-metal E/K fastening. Do not assign it to external P+/P− or the PE screw.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 22-23, M5/6 torque pictograms
Documented
- Mounting hole dimensions
- Not documented
Details
The tool list prints hammer drill @φ8mm but no complete hole/depth specification is assigned.
Location: PDF page 21, tool list
Not documented
- Power cable installation
- PDF page 23: Secure cables and copper bars (Items F, N, V, Q) to battery pack using mounting screw (Item K). Ensure High-Voltage Control Box and CQ16 are sequentially connected in series circuit.; PDF page 23: When connecting copper bar with high voltage, the work must be implemented by professional electrical operators with insulation gloves.; PDF page 23: M5/6; PDF page 23: 3~4N·m; PDF page 25: Remove screw securing decorative cover with screwdriver. Step 2 Remove decorative cover. Step 3 Route power cables (Item G&H) through right-side cable duct. Step 4 Connect all six power cables (Item G&H) individually. Ensure firm and reliable connections.; PDF page 27: See the user manual of the inverter for details on the cable steps.; PDF page 27: Make sure that the power cable connected to the battery is connected vertically and t hat the vertical length is greater than 30cm. If the cable is bent close to the terminals, it may cause poor line contact and result in burnt terminals.; PDF page 27: Power cables must be routed linearly at an appropriate length and must not be subjected to any tensile (pulling) or torsional (twisting) stress. Excess cable length shall not be coiled, looped, or tightly bundled, as this creates an inductive loop effect and severe thermal accumulation. Failure to comply can melt the insulation, leading to short circuits, equipment damage, or catastrophic fire. The installer and end-user are responsible for ensuring the cables are deployed in accordance with this warning.; PDF page 27: ≥30cm; PDF page 27: ≥90°; PDF page 27: R≥6×D; PDF page 27: D'Official user manualCable geometry prose and diagram use different bounds
The prose requires vertical length greater than 30cm; the diagram prints ≥30cm, ≥90° and R≥6×D. Both contexts remain, with no absolute bend radius or reconciled bound computed.
Sources
Assembled CQ16 plus High-Voltage Control Box system. Internal Item K fastening is M5/6, 3~4N·m; it does not give external connector torque. External six-cable procedure, routing/coiling warnings and inverter-manual reference stay complete. Prose >30cm and diagram ≥30cm remain separately attributed.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 23, 25, 27
Documented
- Compatibility requirements
- PDF page 13: CQ16 is the battery module, it needs to be used with High-Voltage Control Box controller;; PDF page 13: High-Voltage Control Box is the controller of the whole system, so each system must have one High-Voltage Control Box;; PDF page 13: Our system consists of at least 4 CQ16+ 1 High-Voltage Control Box and up to 15 CQ16+ 1 High-Voltage Control Box.; PDF page 8: Do not connect the battery directly to inverter conductors or PV conductors. This will damage the battery and may result in explosion.; PDF page 8: Do not interchange the positive and negative terminals of the battery.; PDF page 8: Ensure that there is no short circuit of the terminals or with any external device.; PDF page 8: Do not exceed the battery voltage rating of the inverter.; PDF page 8: Do not connect the battery to any incompatible inverter.; PDF page 8: Do not connect different battery types together.; PDF page 8: Do not install with other batteries or cells.; PDF page 18: Communication cable (BMS-Inverter) (Only FOX PCS)*1; PDF page 19: Accessory package1 / For1+4System: P Front fixed sheet metal*2; Q Negative connection cable*1; R Base*1; S Handle*4; PDF page 19: Accessory package2: R Base*4; S Handle*4; PDF page 19: Accessory package3 / For1+15System: P Front fixed sheet metal*2; T Base-fixed metal*3; U Communication cable(long)*3; Q Negative connection cable*1; V Power cable(red)*3; PDF page 18, controller component package: A High-Voltage control box*1; B High-Voltage control box decorative cover*1; C Cable ties*20; D Quick Installation Guide*1; E Fixed grounding metals*4; F Positive copper bar*1; G Power+ cable*3; H Power- cable*3; I Grounding cable*1; J Communication cable (BMS-Inverter) (Only FOX PCS)*1; K Mounting screw pack*10; PDF page 18, CQ16 component package: L CQ16*1; M CQ16 decorative cover*1; K Mounting screw pack*10; E Fixed grounding metals*4; N Series copper bar*1; O Communication cable(short)*1Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Minimum 4 and maximum 15 CQ16 modules with one controller are system counts, not a sale quantity. The supplied J cable label Only FOX PCS is not an exact inverter-model compatibility list. The inverter own manual controls its connection steps. Accessory packages remain separately labeled assembly contexts, not automatic component-package or system-bundle contents.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 8, 13, 18, 19
Documented
- Storage capacity loss claim
- PDF page 33: If the battery is stored over one year, 5%- 8% of the capacity may lose irreversibly.Official user manual
Sources
Conditional maker capacity-loss claim after storage over one year, not a lifetime or cycle-life rating.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 33
Documented
- External fuse breaker rating
- Not documented
Details
Fire instructions mention a circuit breaker and the fault list names HVB/Module FUSE faults, without an external fuse/breaker rating.
Location: Reviewed CQ16 manual, PDF pages 1-37
Not documented
- Installation SOC requirement
- PDF page 8: Please ensure on installation site that the deviation of voltages between new batteries and every single present battery is less than 0.5V.; PDF page 8: Recommend to check the new batteries mounted on-site comply to the warranty scope or have ever been re-charged within 6 months; on top of that, please make sure the SOC of present battery system onsite is 50%±5%.Official user manual
Sources
Initial installation voltage deviation <0.5 V and recommended recharge-within-six-months/SOC 50%±5% conditions. The later expansion paragraph remains separate.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 8
Documented
- Storage recharge instruction
- PDF page 33: The battery module should be stored in an environment with a temperature range between -20°C- +55°C, and charged regularly according to the table below with no more than 0.5 C(A C-rate is a measure of the rate at which a battery is discharged relative to its maximum capacity.) to the SOC of 50% after a long time of storage.Official user manual
Sources
Battery-module storage/recharge chapter with ≤0.5 C and SOC 50% conditions, separate from scalar storage-temperature tables. No current is calculated from C-rate.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 33
Documented
- Inverter interface protection
- PDF page 16: Inverter interface protection: Over Voltage, Over Current, External Short Circuit, Reverse Polarity, Ground Fault, Over Temp, In Rush Current.Official user manual
Sources
Assembled CQ16 plus High-Voltage Control Box system. Printed connected-system inverter-interface protection list, not independent testing or an external protective-device rating.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF page 16
Documented
- Manufacturer fire instructions
- Sources disagreeUnresolvedOfficial user manualManual gives different fire instructions
Page 6 prohibits water; page 8 says dry powder only and no liquid extinguishers; page 10 names FM-200 or CO2 for the battery and ABC for other parts, with safe-disconnection and evacuation conditions. All full passages remain cited without a selected method.
Why values differ
Assembled CQ16 plus High-Voltage Control Box system. Different complete connected-battery fire passages remain unresolved; no procedure is chosen.
Prohibit the use of water to extinguish fires.Complete separate manufacturer fire passage, preserved as printed.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentIn case of fire, use only dry powder fire extinguisher. Liquid extinguishers should not be used.Complete separate manufacturer fire passage, preserved as printed.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentIn situations where the battery is on fire, if it is safe to do so, disconnect the battery pack by turn off the circuit breaker to shut off the power to the system. Use FM-200 or CO2 fire extinguisher for the battery and an ABC fire extinguisher for the other parts of the system. Under any fire situation, please evacuate the people from the building immediately before trying to extinguish it.Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentComplete separate manufacturer fire passage, preserved as printed.
Official user manual: Fox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2 Rev V1.1.2 · Checked · Earlier documentLocation: PDF pages 6, 8 and 10
Sources disagree
Published claims and calculations, not independent test results.
Documents
- PDFOpenFox ESS CQ Series CQ16 / High-Voltage Control Box User Manual, V1.1.2Official
Our copy is kept as private evidence and is not available to download. SHA-256: 44432a5cbf1041e0ee296dc22674e5bfa93b80fd811d7d714bf833e66f92087d, captured .
Source details
Original official-host PDF retained from the maker public download filter. Request start 2026-11-04T13:06:19.957Z; acquisition end 2026-11-04T13:06:37.786Z. Printed revision date 2026-08 (month precision only).
Location: PDF pages 13-15, CQ16 / controller / named system tables; PDF page 5, scope; PDF page 23, stacking instruction
Retrieved
Manufacturer claims, not independent tests or issuer verification. Global is a download label, not country applicability. Private evidence only; no public figure crop or numeric warranty inference. Manual High-Voltage Control Box name is not assumed to be the datasheet CQ BOX code.
Warranty
No warranty terms on file.
Sellers
No sellers found.
Price history
No seller price history.
Owner reviews
No reviews yet
Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificates evidence needed; Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
High-voltage stacked batteries · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty term, Warranty energy disclosure, Lifetime / capacity, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Certificates
No certificates on file. Certificate guide
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- CQ 80.35
Manufacturer SKU unknown
No historical observations recorded yet.
Community discussions
No discussions linked yet. Search DIY Solar Forum
Recalls / legal notices
No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice
Something wrong that is not one of the values above?
Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.