W 339 × H 256 × D 330 mm / W 13.3 × H 10.1 × D 13 in converted
Printed as "Battery Dimensions (HxWxD) 256 x 339 x 330 mm" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), 14-24-3000 Technical Specifications. Height by width by depth as printed.
Where: PDF page 16, 14-24-3000 Technical Specifications, Mechanical Specifications
Printed as "3 second Peak Current 350 Adc 350 Adc 263 Adc 219 Adc" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), section 2.1 Maximum Battery Operating Limits table, 14-24-3000 column. The second figure is the 14-24-3000 column, for 3 seconds.
Where: PDF page 4, section 2.1 Maximum Battery Operating Limits table, 14-24-3000 column
Printed as "Nominal Energy 2918 Wh" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), 14-24-3000 Technical Specifications. The manual prints the figure in watt hours; it is shown here in kilowatt hours.
Where: PDF page 16, 14-24-3000 Technical Specifications, Electrical Specifications
Printed as "Continuous Charge Current1 150 Adc 114 Adc 76 Adc 57 Adc" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), section 2.1 Maximum Battery Operating Limits table, 14-24-3000 column. The second figure is the 14-24-3000 column; the BMS disconnects the battery above this limit.
Where: PDF page 4, section 2.1 Maximum Battery Operating Limits table, 14-24-3000 column
Printed as "Continuous Discharge Current1 150 Adc 114 Adc 76 Adc 57 Adc" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), section 2.1 Maximum Battery Operating Limits table, 14-24-3000 column. The second figure is the 14-24-3000 column. The same table prints a 20 minute discharge current of 150 Adc.
Where: PDF page 4, section 2.1 Maximum Battery Operating Limits table, 14-24-3000 column
Printed as "Regulatory Approvals UN 38.3 IEC 62619 UL 1973" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), 14-24-3000 Technical Specifications. The manufacturer's claim; no certificate was read.
Where: PDF page 16, 14-24-3000 Technical Specifications, Regulatory Approvals
Printed as "Recommended low voltage cut off: 12 V | 24 V | 36 V | 48 V" in Discover Energy Systems' 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F), section 7.4 Discharging. A recommended setting; the second figure is the 14-24-3000, matching the order of the four models in the charge table above it.
28.64 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 339 × H: 256 × D: 330 mm / W: 13.3 × H: 10.1 × D: 13 in40 kg / 88 lb0.1 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
16/100Missing details45% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Warranty energy disclosure evidence needed; Lifetime / capacity evidence needed; Cell model disclosure evidence needed.
24 V · Format not recorded · Rated capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
CertificatesUL 1973Claimed15.75 / 45
35 evidence points · 45% weight
UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.
Research pending, 0 points: Warranty term, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
UL 1973manufacturer claimpresent at observation[1]
Scope
battery pack scope unverified
Covered models
14-24-3000
Limitations
A manufacturer claim, not a listing or certificate. Printed as "Regulatory Approvals UN 38.3 IEC 62619 UL 1973" on the 14-24-3000 technical specifications page (section 13, PDF page 16; battery model 900-0043) of Discover Energy Systems' operating manual for the 14-12-3000, 14-24-3000, 14-36-3000 and 14-48-3000 batteries, revision 805-0022 REV F, captured on October 1, 2026. Each model has its own specifications page; this one names 14-24-3000. No issuer, certificate or report number is printed; the issuer's record was not checked. The manual does not say whether the approval covers the cell, the module or the battery.
Registration needs the battery serial number; registration details at discoverlithium.com
Printed as "To register your product you will need the serial number of the battery. Visit discoverlithium.com for registration details." No warranty term is printed in this manual.
UL 1973Manufacturer claim · battery pack scope unverifiedClaimedListed when checked
A manufacturer claim, not a listing or certificate. Printed as "Regulatory Approvals UN 38.3 IEC 62619 UL 1973" on the 14-24-3000 technical specifications page (section 13, PDF page 16; battery model 900-0043) of Discover Energy Systems' operating manual for the 14-12-3000, 14-24-3000, 14-36-3000 and 14-48-3000 batteries, revision 805-0022 REV F, captured on October 1, 2026. Each model has its own specifications page; this one names 14-24-3000. No issuer, certificate or report number is printed; the issuer's record was not checked. The manual does not say whether the approval covers the cell, the module or the battery.
Location: PDF page 1, cover and contents; PDF pages 15 to 18, technical specifications per model
Retrieved Oct 1, 2026
Discover Energy Systems' own operating manual for the 14-12-3000, 14-24-3000, 14-36-3000 and 14-48-3000 AES batteries, captured 1 October 2026 from discoverenergysys.com; revision 805-0022 REV F as printed; its cover names these four models and it has a technical specification page for each. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Discover Energy Systems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Discover Energy Systems 14-12-3000 / 14-24-3000 / 14-36-3000 / 14-48-3000 Operating Manual (805-0022 REV F)
Archived copy of a document published by Discover Energy Systems. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Battery pack claim; verification pending. A manufacturer claim, not a listing or certificate. Printed as "Regulatory Approvals UN 38.3 IEC 62619 UL 1973" on the 14-24-3000 technical specifications page (section 13, PDF page 16; battery model 900-0043) of Discover Energy Systems' operating manual for the 14-12-3000, 14-24-3000, 14-36-3000 and 14-48-3000 batteries, revision 805-0022 REV F, captured on October 1, 2026. Each model has its own specifications page; this one names 14-24-3000. No issuer, certificate or report number is printed; the issuer's record was not checked. The manual does not say whether the approval covers the cell, the module or the battery.
note: UL 1973: strongest qualifying evidence, counted once. Product-scoped manufacturer claim; issuer verification pending. Applies: UL 1973; CEC not applicable to 12 V / 24 V / 36 V DC modules; UL 9540 not applicable to 12 V / 24 V / 36 V DC modules.