Printed as 73kg for the main unit alone; the other columns print 136kg to 388kg for the main unit with one to five expansion batteries. The product page prints "73kg Nettogewicht".
Where: PDF page 2, Allgemeine Parameter, Gewicht, first column
Printed as "Akkulebensdauer 10.000 Zyklen"; no test conditions are printed. The product page prints "10000 Zyklen; 10 Jahre Lebensdauer & Herstellergarantie".
Where: PDF page 2, Akkusystem-Parameter, Akkulebensdauer
W 356 × H 325 × L 670 mm / W 14 × H 12.8 × L 26.4 in converted
Printed as "Abmessungen (L x H x T) 670x356x325mm" for the main unit alone, in the maker's order length x height x depth (stored here in that order: 670, 356, 325). The product page prints "670 × 356 × 325mm Abmessungen".
Where: PDF page 2, Allgemeine Parameter, Abmessungen, first column
Expands with up to five BP7000 expansion batteries (7kWh to 42kWh per main unit); the page also prints 126kWh for three parallel units.
The datasheet prints configurations "1" to "1 + 5" (main unit plus expansion batteries) at 7kWh to 42kWh. The product page prints "42kWh × 3 = 126kWh Maximale Speicherkapazität" and "(Drei parallele Einheiten)", and states the BP7000 is only compatible with the Solarbank Max AC.
Where: PDF page 2 system table; product page technical details and FAQ
Printed as "Max. Eingangs- / Ausgangsleistung: 3,5kW Netzanschluss" (grid connection). The datasheet prints "Nenneingangsstrom 15,2A a.c."; its "Maximale Lade-/Entladeleistung" row prints "3,5kW 3,68/5kW" across the configuration columns without saying which column each figure belongs to, so it is not used.
Battery terminal nominal; internal battery nominal is separately printed as 22.4 V.
Printed battery terminal nominal voltage 400 V d.c.; the same table separately prints battery/internal nominal 22.4 V d.c. and terminal/battery voltage range 360–450 V d.c. This is not PV input or AC output; no internal battery rating is replaced.
Where: Anker German Solarbank Max AC / BP7000 datasheet, PDF p2, Akkusystem-Parameter, Klemmen-Nennspannung
Printed as "Maximale Ausgangsscheinleistung 3,68kVA" for the grid port; the AC backup port prints "Maximale kontinuierliche Ausgangsscheinleistung 3,68kVA".
Where: PDF page 2, Netzeingangs-/Ausgangsparameter, Maximale Ausgangsscheinleistung
Printed as "Nennspannung 22,4V d.c." in the battery system parameters. The same table prints a separate terminal nominal voltage, "Klemmen-Nennspannung 400V d.c.", and a battery voltage range of 360-450V d.c.
Where: PDF page 2, Akkusystem-Parameter, Nennspannung
Printed as "Nennkapazität" (rated capacity) 7kWh for the configuration "1" (main unit only); the other columns print 14 to 42kWh for the main unit plus one to five expansion batteries. The product page prints "7kWh Nennleistung" and "7kWh Basisspeicher". The datasheet prints no usable-energy figure; it prints "Entladetiefe 100%".
Where: PDF page 2, system table, Nennkapazität, first column (1 main unit, no expansion battery)
Printed for the grid port as "Nennausgangswirkleistung 0,8/3,5kW" (rated active output power). The product page says the output is set to 800W by default on the Schuko plug and can be raised to up to 3500W in the app on a dedicated circuit (Wieland plug or hardwired).
Where: PDF page 2, Netzeingangs-/Ausgangsparameter, Nennausgangswirkleistung
Printed for the AC backup output as "Nennausgangswirkleistung 3,5kW" with "Nennausgangsstrom 16A a.c." and "Maximale kontinuierliche Ausgangsscheinleistung 3,68kVA".
Where: PDF page 2, AC-Backup-Ausgangsparameter, Nennausgangswirkleistung
Printed as 42kWh for one main unit plus five expansion batteries ("1 + 5"). The product page FAQ says the Solarbank Max AC supports at most 5 BP7000 expansion batteries for a total capacity of up to 42kWh. The page also prints "42kWh × 3 = 126kWh Maximale Speicherkapazität"; that three-unit figure is kept in expansion_notes.
Where: PDF page 2, system table, Nennkapazität, last column (1 + 5)
77.52 L* (Calculated enclosure volume: W × H × D in mm ÷ 1,000,000)W: 356 × H: 325 × L: 670 mm / W: 14 × H: 12.8 × L: 26.4 in73 kg / 160 lb0.09 kWh/L* (Rated or usable capacity shown on this card ÷ enclosure volume)
Evidence score
17/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificates evidence needed; Warranty energy disclosure evidence needed; Cell model disclosure evidence needed.
AC-coupled · Stackable · Usable capacity
The warranty term and the lifetime energy are each scored against the best documented value for a home storage battery: a value earns its share of that best, times the weight. A documented value always earns points; an undisclosed one earns 0.
Research pending, 0 points: Certificates, Warranty energy disclosure, Cell model disclosure.
Computed from public specifications and evidence records. Warranty duration is not service quality; certificate evidence points are not a safety rating. Compatibility and installation limits still apply.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: PDF pages 2 and 3
Retrieved Sep 28, 2026
Anker SOLIX's German four-page datasheet for the Solarbank Max AC and the BP7000 Zusatzakku, linked from the German product page as "Solarbank Max AC – Datenblatt.pdf" (dated 2026-05-22 there), captured September 29, 2026. PDF page 2 prints the Solarbank Max AC system table (one main unit plus zero to five expansion batteries); PDF page 3 prints the BP7000 battery table. No revision is printed. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by Anker SOLIX. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-29.
Location: Page text
Retrieved Sep 28, 2026
Anker SOLIX's German store page for the Solarbank Max AC, captured September 29, 2026. Cited for its technical details block, FAQ answers and download list. Manufacturer claims, not independently verified.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Anker SOLIX Solarbank Max AC datasheet, German (Datasheet_20260526_E2_AC_DE.pdf)
Archived copy of a document published by Anker SOLIX. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].