SunPro Power SP410-108M10
- Brand
- SunPro Power
- Model
- SP410-108M10
- SKU / part number
- ?
- Category
- Solar panels
chargedreviews.com/panels/sunpro-power-sp410-108m10
Electrical at STC
Temperature and system limits
- Temperature coefficient, Pmax
- -0.34 %/°C [1]
- Temperature coefficient, Voc
- -0.27 %/°C [1]
- Temperature coefficient, Isc
- 0.048 %/°C [1]
- Maximum system voltage
- 1,500 V Needs confirmation [2]
- Maximum series fuse
- 25 A [1]
- NOCT / NMOT
- ?
- Rated output at NMOT
- ?
- Operating temperature
- -40 to 85 °C / -40 to 185 °F converted [1]
Cells and construction
Mechanical and connections
Installation (from the manual)
Torque
- Clamp or bolt torque
- 16 to 20 N·m [2]
Conductors
- Cable bending radius / connector notes
- The minimum bending radius of the cables must be 43mm. [2]
Clearances and orientation
- Mounting methods and clamp zones
- PV modules can be installed through clamp method.; Use at minimum 4 clamps to attach modules to the mounting rails.; The clamp must overlap the module frame by at least 7mm but no more than 10mm.; A=1/4L±50mm; +5400Pa/-2400Pa; S=100~240mm; Lower; This installation mode is not recommended [2]
Grounding
- Grounding
- On a grounding hole with a diameter of φ4 mm, use a separate grounding wire; M4*12mm bolts and M4 nuts, star washers and plain washers; ground fixation is 4N·m~8N·m; It is recommended to use the copper wire (4-14mm2 or AWG 6-12) [2]