Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "Anodized aluminum alloy". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Frame)
SunPro Power's SP (395/420W)-108M10 datasheet prints the SP410-108M10 at STC as "410.00 31.25 13.12 37.33 13.90" (Pmax, Vmp, Imp, Voc, Isc); the Maximum power current (Imp) figure reads 13.12. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SP410-108M10 row, Maximum power current (Imp)
SunPro Power's SP (395/420W)-108M10 datasheet prints the SP410-108M10 at STC as "410.00 31.25 13.12 37.33 13.90" (Pmax, Vmp, Imp, Voc, Isc); the Short circuit current (Isc) figure reads 13.90. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SP410-108M10 row, Short circuit current (Isc)
SunPro Power's SP (395/420W)-108M10 datasheet prints the SP410-108M10 at STC as "410.00 31.25 13.12 37.33 13.90" (Pmax, Vmp, Imp, Voc, Isc); the Maximum power voltage (Vmp) figure reads 31.25. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SP410-108M10 row, Maximum power voltage (Vmp)
SunPro Power's SP (395/420W)-108M10 datasheet prints the SP410-108M10 at STC as "410.00 31.25 13.12 37.33 13.90" (Pmax, Vmp, Imp, Voc, Isc); the Open circuit voltage (Voc) figure reads 37.33. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SP410-108M10 row, Open circuit voltage (Voc)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "108 cells, Mono Crystalline Silicon, 91x182mm(3.58x7.17in)-10BB". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Cell)
On a grounding hole with a diameter of φ4 mm, use a separate grounding wire; M4*12mm bolts and M4 nuts, star washers and plain washers; ground fixation is 4N·m~8N·m; It is recommended to use the copper wire (4-14mm2 or AWG 6-12)
Printed as "On a grounding hole with a diameter of φ4 mm, use a separate grounding wire", "M4*12mm bolts and M4 nuts, star washers and plain washers", "ground fixation is 4N·m~8N·m" and "It is recommended to use the copper wire (4-14mm2 or AWG 6-12)" in the Grounding section of Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Regular Modules Installation Manual (no revision printed). The same section also allows grounding by unused mounting holes or other certified grounding devices (UL467) and recommends 10-12 AWG bare copper wire for the traditional method.
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SP410-108M10. Printed value: "20.3kg(44.75Ib) Maximum system voltage 1000V". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Weight 20.3kg(44.75Ib) Maximum system voltage"
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "108 cells, Mono Crystalline Silicon, 91x182mm(3.58x7.17in)-10BB". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Cell)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "MC4 Compatible Connector". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Connector)
Printed beside the Front glass row label as "3.2mm, ultra clear embossed tempered coated glass" in SunPro Power P-type SPxxx-108M10 395-420W (30mm compatible) datasheet, captured on September 28, 2026.
Where: Page 2, Structural Characteristics table, Front glass row (confirmed by page render; the extracted text runs the row values together but keeps each value contiguous and unscrambled)
Printed as "Applied torque should refer to mechanical design standard according to the bolt customer is using, ex: M8 16-20N.m(140-180lbf.in)" in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Regular Modules Installation Manual (no revision printed). Given as an example for an M8 clamp bolt; the manual says the applied torque should follow the mechanical design standard for the bolt used. Printed in N.m first, with 140-180 lbf.in beside it.
Where: PDF page 31, section 5.4.1, Mounting with Clamps, torque sentence
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "IP68". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Junction box)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "+5400Pa/-2400Pta". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Mechanical load capacity)
W 1,134 × H 1,722 × D 30 mm / W 44.65 × H 67.8 × D 1.2 in converted
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SP410-108M10. Printed value: "1722x1134x30mm". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Module size (L*W*H) 1722x1134x30mm(67.80x44.65x1.18in) Power tolerance 0~+5W"
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "+5400Pa/-2400Pta". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Mechanical load capacity)
SunPro Power's SP (395/420W)-108M10 datasheet prints the SP410-108M10 at STC as "410.00 31.25 13.12 37.33 13.90" (Pmax, Vmp, Imp, Voc, Isc); the Power (Pmax/W) figure reads 410.00. Revised on 17 October 2026: The Internet Archive copy is not a usable source; the fact stays as SunPro Power's own document prints it (PM, October 17, 2026).
Where: Datasheet, Electrical Characteristics table (STC), SP410-108M10 row, Power (Pmax/W)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "25A". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Maximum rated fuse current)
PV modules can be installed through clamp method.; Use at minimum 4 clamps to attach modules to the mounting rails.; The clamp must overlap the module frame by at least 7mm but no more than 10mm.; A=1/4L±50mm; +5400Pa/-2400Pa; S=100~240mm; Lower; This installation mode is not recommended
Printed as "PV modules can be installed through clamp method." (PDF page 30, section 5.4.1) and "Use at minimum 4 clamps to attach modules to the mounting rails." (PDF page 31) in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Regular Modules Installation Manual (no revision printed). The clamp table on PDF page 32, row "60/72/108/110/120 /132/144/156pcs Module", gives "+5400Pa/-2400Pa" for clamps at "A=1/4L±50mm" on rails perpendicular to the long side frame, and "Lower" for clamps at "S=100~240mm" on rails perpendicular to the short side frame, of which it says "This installation mode is not recommended". The loads are described there as an empirical value of a standard module; section 5.2 of the same manual calls 3600 (front)/1600 (back) the design pressure, so the manual prints two different load figures. The value lists the long-side clamp position and its load, then the short-side clamp position, its load entry and the table's remark, in the table's order.
Where: PDF pages 30-32, section 5.4.1 Mechanical Installation and Warning, Mounting with Clamps and clamp table
The minimum bending radius of the cables must be 43mm.
Printed as "The minimum bending radius of the cables must be 43mm." in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Regular Modules Installation Manual (no revision printed), a statement for all its modules' PV cables.
SunPro Power's SP (395/420W)-108M10 datasheet prints "0~+5W 1000V 25A" (Power tolerance, Maximum system voltage, Maximum rated fuse current); the Maximum rated fuse current reads 25 A for the series, which includes the SP410-108M10. Revised on 17 October 2026: The fact rested only on an Internet Archive copy of SunPro's installation manual, which is no longer published (its URL now redirects to the home page); SunPro's own live datasheet prints the same value, so the fact is re-cited to it (PM, October 17, 2026).
Where: Datasheet, Operating Parameters, Maximum rated fuse current
The installation manual prints 1500 V; the data sheet prints 1000 V. Zhejiang Sunpro's installation manual for its regular (single glass) modules prints 1500 V dc as the maximum system voltage in the SP410-108M10 row, while the SunPro Power US data sheet for the SPxxx-108M10 395-420W 30mm Compatible modules prints 1000 V. Check the module label before designing a string.
Printed as "SP410-108M10 37.33 31.25 1500 13.12 13.90 410 Class II" in Zhejiang Sunpro's SUNPRO PV MODULES INSTALLATION MANUAL, Regular Modules Installation Manual (no revision printed), section 3.6 Electrical Rating, the SP410-108M10 row of the SPxxx-108M10 table; the Maximum System Voltage, (V dc) column reads 1500. Revised on 1 October 2026: Zhejiang Sunpro's installation manual prints a maximum system voltage of 1500 V dc in this model's row of its electrical rating table, and the manual comes first in the source order; the recorded 1000 V from the US data sheet is kept as an alternative.
Where: PDF page 15, section 3.6 Electrical Rating, SPxxx-108M10 table, SP410-108M10 row, Maximum System Voltage, (V dc) column
Sources
1,000 V
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SP410-108M10. Printed value: "1000V". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from the column headed SP410-108M10. Printed value: "20.97%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "-40~+85℃". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, STRUCTURAL CHARACTERISTICS / OPERATING PARAMETERS (shared by every model on this datasheet) (Operating temperature range)
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SP410-108M10. Printed value: "(TK Pmax) -0.34% / ℃". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Connector MC4 Compatible Temp. Coefficient of Pmax (TK Pmax) -0.34% / ℃"
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "0.048% / ℃". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, TEMPERATURE CHARACTERISTICS (Temp. Coefficient of Isc)
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a table or row headed by model SP410-108M10. Printed: "-0.27% / ℃". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: page 2, TEMPERATURE CHARACTERISTICS (Temp. Coefficient of Voc)
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from SunPro Power's published document at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from the column headed SP410-108M10. Printed value: "20.97%". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Printed on the warranty panel of the SunPro Power SP (395/420W)-108M10 datasheet (www.sunpropower.us) as a 12 year "Quality Guarantee" and a 25 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SP (395/420W)-108M10 family. The datasheet does not print the warranty terms, exclusions or claim process, and adds "Extended warranty available upon request at additional cost".
Printed on the warranty panel of the SunPro Power SP (395/420W)-108M10 datasheet (www.sunpropower.us) as a 12 year "Quality Guarantee" and a 25 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SP (395/420W)-108M10 family. The yearly output steps are printed only as chart labels.
Power temperature coefficient-0.34 %/°C10.4 / 16.0
0.34 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Read from the datasheet this catalog row already cites, at https://www.sunpropower.us/wp-content/uploads/2026/06/P-type-SPxxx-108M10-395-420W-30mm-Compatible.pdf, from a row the sheet prints once for every model it covers, including SP410-108M10. Printed value: "(TK Pmax) -0.34% / ℃". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
12 years
Printed on the warranty panel of the SunPro Power SP (395/420W)-108M10 datasheet (www.sunpropower.us) as a 12 year "Quality Guarantee" and a 25 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SP (395/420W)-108M10 family. The datasheet does not print the warranty terms, exclusions or claim process, and adds "Extended warranty available upon request at additional cost".
Printed on the warranty panel of the SunPro Power SP (395/420W)-108M10 datasheet (www.sunpropower.us) as a 12 year "Quality Guarantee" and a 25 year "Power Warranty" under the heading "WARRANTY CERTIFICATE", captured on September 25, 2026, one statement for every model of the SP (395/420W)-108M10 family. The yearly output steps are printed only as chart labels.
Zhejiang Sunpro Power Technology's own installation manual for its single glass solar modules ("REGULAR MODULES INSTALLATION MANUAL", document No. SP-WI-JS-010), English and Chinese. It was obtained from the Internet Archive's Wayback Machine copy of Zhejiang Sunpro's own file at sunpropower.com (snapshot of March 23, 2025), because sunpropower.com now redirects to the SunPro Power US home page and the copy Zhejiang Sunpro posted in January 2026 could not be read; that later file is named for the same revision date as this copy's internal date (July 16, 2024), but its content was not compared. No revision is printed in the document. Its electrical rating table (section 3.6) has a row per power class for each series it names, and its installation sections apply to all the maker's single glass modules; it gives series-level installation instructions and tabulated ratings, and mechanical loads depend on the mounting method. Manufacturer instructions, not independent tests. It names, among others, the SPxxx-108M10 series with rows SP390-108M10 to SP420-108M10.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: P-type Solar Module products list
Retrieved Sep 24, 2026
SunPro Power North America product page on www.sunpropower.us listing the SPDGxxx-144M10 540-565W, SPxxx-108M10 395-420W series, each with one product image and a link to its datasheet, captured on September 25, 2026. It names series (for example SPDGxxx-N96R12), not individual wattage models, so each image shows the series rather than one wattage.
Archived copy of a document published by SunPro Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by SunPro Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].