Manufacturer source conflict. SEG's 2026 datasheet (SEG_DS_EN_2026V1.0) prints 13.20 and its 2025 datasheet (SEG_DS_EN_2025V2.0) prints 13.46 for the SEG-440-BTD-BG maximum power current.
Printed as "440 39.28 13.92 33.32 13.20" (Maximum Power, Open Circuit Voltage, Short Circuit Current, Maximum Power Voltage and Maximum Power Current) in the SEG-440-BTD-BG STC column of SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Electrical Characteristics, row "Maximum Power Current -Imp(A)". Revised on 1 October 2026: SEG's current datasheet (SEG_DS_EN_2026V1.0) prints 13.2 A for the maximum power current of SEG-440-BTD-BG; the recorded 13.46 A comes from SEG's earlier 2025 datasheet, kept beside it.
Printed as "440 39.30 14.15 32.70 13.46" in the SEG-440-BTD-BG STC Front column of SEG Solar's Yukon N SEG-XXX-BTD-BG-108Cells datasheet (SEG_DS_EN_2025V2.0, a copy hosted by a distributor), page 2, row "Maximum Power Current -Imp(A)".
Manufacturer source conflict. SEG's 2026 datasheet (SEG_DS_EN_2026V1.0) prints 13.92 and its 2025 datasheet (SEG_DS_EN_2025V2.0) prints 14.15 for the SEG-440-BTD-BG short circuit current.
Printed as "440 39.28 13.92 33.32 13.20" (Maximum Power, Open Circuit Voltage, Short Circuit Current, Maximum Power Voltage and Maximum Power Current) in the SEG-440-BTD-BG STC column of SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Electrical Characteristics, row "Short Circuit Current -Isc(A)". Revised on 1 October 2026: SEG's current datasheet (SEG_DS_EN_2026V1.0) prints 13.92 A for the short circuit current of SEG-440-BTD-BG; the recorded 14.15 A comes from SEG's earlier 2025 datasheet, kept beside it.
Printed as "440 39.30 14.15 32.70 13.46" in the SEG-440-BTD-BG STC Front column of SEG Solar's Yukon N SEG-XXX-BTD-BG-108Cells datasheet (SEG_DS_EN_2025V2.0, a copy hosted by a distributor), page 2, row "Short Circuit Current -Isc(A)".
Manufacturer source conflict. SEG's 2026 datasheet (SEG_DS_EN_2026V1.0) prints 33.32 and its 2025 datasheet (SEG_DS_EN_2025V2.0) prints 32.70 for the SEG-440-BTD-BG maximum power voltage.
Printed as "440 39.28 13.92 33.32 13.20" (Maximum Power, Open Circuit Voltage, Short Circuit Current, Maximum Power Voltage and Maximum Power Current) in the SEG-440-BTD-BG STC column of SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Electrical Characteristics, row "Maximum Power Voltage -Vmp(V)". Revised on 1 October 2026: SEG's current datasheet (SEG_DS_EN_2026V1.0) prints 33.32 V for the maximum power voltage of SEG-440-BTD-BG; the recorded 32.7 V comes from SEG's earlier 2025 datasheet, kept beside it.
Printed as "440 39.30 14.15 32.70 13.46" in the SEG-440-BTD-BG STC Front column of SEG Solar's Yukon N SEG-XXX-BTD-BG-108Cells datasheet (SEG_DS_EN_2025V2.0, a copy hosted by a distributor), page 2, row "Maximum Power Voltage -Vmp(V)".
Manufacturer source conflict. SEG's 2026 datasheet (SEG_DS_EN_2026V1.0) prints 39.28 and its 2025 datasheet (SEG_DS_EN_2025V2.0) prints 39.30 for the SEG-440-BTD-BG open circuit voltage.
Printed as "440 39.28 13.92 33.32 13.20" (Maximum Power, Open Circuit Voltage, Short Circuit Current, Maximum Power Voltage and Maximum Power Current) in the SEG-440-BTD-BG STC column of SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Electrical Characteristics, row "Open Circuit Voltage -Voc(V)". Revised on 1 October 2026: SEG's current datasheet (SEG_DS_EN_2026V1.0) prints 39.28 V for the open circuit voltage of SEG-440-BTD-BG; the recorded 39.3 V comes from SEG's earlier 2025 datasheet, kept beside it.
Printed as "440 39.30 14.15 32.70 13.46" in the SEG-440-BTD-BG STC Front column of SEG Solar's Yukon N SEG-XXX-BTD-BG-108Cells datasheet (SEG_DS_EN_2025V2.0, a copy hosted by a distributor), page 2, row "Open Circuit Voltage -Voc(V)".
Printed as "Half-Cell N-Type Bifacial Module" and "Bifaciality 80±10%" in SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), which covers SEG-440-BTD-BG; SEG's 2025 datasheet prints the same. Revised on 1 October 2026: The bifacial flag was seller-listed; SEG's own datasheets describe the SEG-440-BTD-BG range as a bifacial module.
A bonding or toothed washer is required to make proper and reliable electrical grounding connection with the anodized aluminum frame.; Consider using a lay-in lug, rated for outdoor use, if the module grounding conductor is to be larger than 10 AWG.
Printed as "A bonding or toothed washer is required to make proper and reliable electrical grounding connection with the anodized aluminum frame." in section 3.8 (Grounding) of SEG's Installation Guide, Photovoltaic Module (Double-glass), 2026 V1.1, with the lay-in lug sentence from the same section. The section also allows devices listed and identified for grounding metallic module frames.
Printed as "1722 x 1134 x 30 mm 24.0 kg" (External Dimension and Weight) in SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Mechanical Specifications, a row the sheet prints once for every model it covers, including SEG-440-BTD-BG. Revised on 1 October 2026: SEG's current datasheet prints this weight for every model it covers, including SEG-440-BTD-BG; SEG's 2025 datasheet the record cited prints the same, and the conditions now quote the printed text.
Printed as "The reference torque value for M8 screw is 16~20N*M." in section 3.4 (Clamp Installation) of SEG's Installation Guide, Photovoltaic Module (Double-glass), 2026 V1.1; section 3.3 (Screw Installation) prints the same M8 value and 9~12N*M for M6 screws.
W 1,134 × L 1,722 × D 30 mm / W 44.65 × L 67.8 × D 1.2 in converted
Printed as "1722 x 1134 x 30 mm 24.0 kg" (External Dimension and Weight) in SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Mechanical Specifications, a row the sheet prints once for every model it covers, including SEG-440-BTD-BG. Revised on 1 October 2026: SEG's current datasheet prints this external dimension for every model it covers, including SEG-440-BTD-BG; SEG's 2025 datasheet the record cited prints the same, and the conditions now quote the printed text.
Printed as "440 39.28 13.92 33.32 13.20" in the SEG-440-BTD-BG STC column of SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, Electrical Characteristics, where the first figure is the row "Maximum Power -Pmp(Wp)"; SEG's 2025 datasheet prints 440 for SEG-440-BTD-BG too. Revised on 1 October 2026: The rated power was seller-listed; SEG's own datasheets print 440 Wp for SEG-440-BTD-BG.
Where: Page 2, Electrical Characteristics, SEG-440-BTD-BG STC column, Maximum Power -Pmp(Wp) row
Printed as "Power Tolerance(W) Maximum System Voltage Maximum Series Fuse Rating (0, +4.99) 1500V DC 30 A" in SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, a row the sheet prints once for every model it covers, including SEG-440-BTD-BG; SEG's 2025 datasheet prints the same. Revised on 1 October 2026: SEG's datasheets print this maximum series fuse rating for every model they cover, including SEG-440-BTD-BG; the conditions now quote the printed text.
Where: Page 2, Mechanical Specifications, Maximum Series Fuse Rating
Screw installation (Table 2): Four outer mounting holes, +5400/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail cross the long side, L=A/4±50mm: +5400/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail parallel the long side, L=A/4±50mm: +2400/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail cross the short side, W=B/4±50mm: +3600/-2400 Pa; Clamp installation (Table 3), clamp length ≥50mm, Mounting rail parallel the short side, W=B/4±50mm: +1600/-1600 Pa
Printed as "SEG-XXX-BMD-BG(1722×1134×30/35) SEG-XXX-BTD-BG(1722×1134×30/35) +5400/-2400 Four outer mounting holes" in Table 2 of SEG's Installation Guide, Photovoltaic Module (Double-glass), 2026 V1.1, with the clamp row quoted here from Table 3 (columns Installation Drawing 1 to 4) and any tracker or special-method row for this series. The hole position for Table 2 was read from rendered page 8 (the table's installation drawing labels). Loads are in Pa as printed; the manual does not say whether they are test or design loads.
Where: PDF page 8 (Table 2, screw installation), PDF page 10 (Table 3, clamp installation)
Printed as "Power Tolerance(W) Maximum System Voltage Maximum Series Fuse Rating (0, +4.99) 1500V DC 30 A" in SEG Solar's Yukon N SEG-XXX-BTD-BG 108-cell datasheet (SEG_DS_EN_2026V1.0), page 2, a row the sheet prints once for every model it covers, including SEG-440-BTD-BG; SEG's 2025 datasheet prints the same. Revised on 1 October 2026: SEG's datasheets print this maximum system voltage for every model they cover, including SEG-440-BTD-BG; the conditions now quote the printed text.
Where: Page 2, Mechanical Specifications, Maximum System Voltage
Printed as "-0.25 %/°C" in SEG Solar Yukon N SEG-XXX-BTD-BG 108-cell datasheet; the specification table row pairs it with the Voc temperature coefficient label (read from the rendered table: "Voc Temperature Coefficient | -0.25 %/°C | Pieces per Pallet | 36 | 36 | 36 | 36").
Where: Specification table, temperature coefficients
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[5]
Scope
equipment listing
Covered models
SEG-440-BTD-BG
Limitations
Model SEG-440-BTD-BG listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under SEG Solar Inc., as "SEG-440-BTD-BG", CEC listing date 2025-05-21. This is an equipment listing, not UL certification or complete-system approval.
Location: Cover page (version) and section 1.1, Applicable Products (scope)
Retrieved Oct 1, 2026
SEG Solar's own installation guide for its double-glass modules, captured 1 October 2026 from segsolar.com, where SEG's Installation Manual download page links it; printed as 2026 V1.1, valid from March 2026, and it states the modules are certified for safety through UL 61730. Section 1.1 (Applicable Products) lists the series it covers by type and size. It gives series-level mounting methods with loads, torques and grounding instructions; it prints no model ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by SEG Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Covers the full-black Yukon N SEG-425 to SEG-445-BTD-BG 108-cell N-type bifacial family only; it does not name any T1/T2/T3 suffixed part number or the 420 W class.
Archived copies
Archived copy of a document published by SEG Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
SEG Solar Yukon N SEG-XXX-BTD-BG 108-cell datasheet
Archived copy of a document published by SEG Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
SEG Solar Installation Guide, Photovoltaic Module (Double-glass) (U.S. UL 61730 edition, 2026 V1.1)
Archived copy of a document published by SEG Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product / system scope unresolved. Model SEG-440-BTD-BG listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under SEG Solar Inc., as "SEG-440-BTD-BG", CEC listing date 2025-05-21. This is an equipment listing, not UL certification or complete-system approval.
at Amazon, read Nov 16, 2026Price as of Nov 16, 2026, 5:25 AM PST, may change
at ACOPOWER, read Nov 15, 2026
View product →
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.