Printed in Italian as "Cornice Lega d’alluminio anodizzato doppio spessore" in Peimar's SG285P datasheet (Italian edition), captured on September 28, 2026. The value is the manufacturer's own Italian wording, not translated; the field was mapped from the Italian row label "Cornice".
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Peimar's SG285P datasheet does not use the words "bifacial"/"bifacciale"/"bifaciale" or "monofacial"/"monofacciale"/"monofaciale", and does not print a front/rear power ratio or bifaciality percentage for this model, so bifaciality is left unknown rather than inferred from cell or backsheet construction.
No source on record
Cell type
Polycrystalline
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian. Cell count, layout and technology as printed in the mechanical characteristics row.
All module frames should be grounded for safety.; Attach a separate ground wire to grounding holes on modules frame with a self tapping screw.; Assemble the recommended grounding lug to the Aluminum frame using stainless steel M3, M4 or M5 screw and hardware as shown below.; Recommended torque of M3, M4 or M5 screw assembly is 0.8NM or 1.5NM.; ground wires greater than 10AWG is recommended
Printed as "All module frames should be grounded for safety." in section 6.3 Grounding (PDF page 13) of Peimar's EN Installation Manual Photovoltaic Modules (Version EN_2024_12_00), Peimar's general installation manual (linked from the maker's product page), which continues on PDF page 14 with the grounding lug assembly (stainless steel M3, M4 or M5 screw, star washer under the lug, flat washer, split lock washer and nut) and its recommended torque, printed as 0.8NM or 1.5NM. The manual notes two grounding hole sizes, the smaller being phased out, and labels the M5 drawing for modules with 5.1 mm grounding holes. General instructions for Peimar's photovoltaic modules, not specific to this model.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Printed in Italian as "Cover Frontale 3,2 mm / 0,13” spessore, vetro temprato" in Peimar's SG285P datasheet (Italian edition), captured on September 28, 2026. The value is the manufacturer's own Italian wording, not translated; the field was mapped from the Italian row label "Cover Frontale".
W 992 × H 1,640 × D 35 mm / W 39.1 × H 64.57 × D 1.4 in converted
Read from Peimar's published document at https://peimar.com/datasheet/Peimar_IT_SG285P.pdf, from the only model this document publishes, SG285P. Printed value: "1640 x 992 x 35/40 mm / 64,5 x 39 x 1,38/1,57”". Standard test conditions as stated on that sheet. No value was taken from another model or from a name.
Mounting using bolt holes; Modules should be bolted to support structures through mounting holes located in the frame’s back flanges only.; Mounting using “clamping method” and profile insert; Each module must be securely fastened at a minimum of 4 points on two opposite sides.
Printed as "Mounting using bolt holes" (section 5.5.1, PDF page 8) and as "Mounting using “clamping method” and profile insert" (section 5.5.2, PDF page 9) in Peimar's EN Installation Manual Photovoltaic Modules (Version EN_2024_12_00), Peimar's general installation manual (linked from the maker's product page). Bolt mounting uses the mounting holes in the frame's back flanges only; clamp mounting needs at least 4 points on two opposite sides. The manual names no model; its clamp zone tables (by cell count and cell size) and approved load figures are not repeated here because they are not stated for this model. General instructions for Peimar's photovoltaic modules, not a test of this model.
Where: PDF page 8 and 9, section 5.5 Mounting (5.5.1 bolt holes, 5.5.2 clamping method and profile insert)
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Where: Page 2, Temperature Characteristics, power temperature coefficient
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Product warranty needed; Power warranty needed; First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
Power temperature coefficient-0.29 %/°C12.1 / 16.0
0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Peimar SG285P datasheet (IT_2025_06_00), printed value for this model. The datasheet is Peimar's Italian-language edition; field labels are printed in Italian.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
SG285P
Limitations
Model SG285P listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under PEIMAR, as "SG285P". This is an equipment listing, not UL certification or complete-system approval.
Location: Cover page and sections 2 (Introduction) and 3 (Applications)
Retrieved Oct 1, 2026
Peimar's own general installation manual for its photovoltaic modules, captured 1 October 2026 from peimar.com. It names no model or series; it is attached to a record only because Peimar's own modules page, which lists that model with its data sheets, links this file as the modules installation manual. Version EN_2024_12_00 as printed on the back cover. Its scope is Peimar photovoltaic modules in general: modules made of crystalline-silicon cells with a plastic back sheet (monofacial) or tempered glass back (bifacial) and an anodized aluminum frame. Only its general installation instructions (mounting methods and grounding stated for all modules) are used; it establishes no model rating, load rating or clamp zone for a particular model. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Single-model Peimar datasheet for SG285P (Italian-language edition); STC values carry a +/-3% measurement tolerance and the sheet covers no other Peimar model or finish variant.
Archived copies
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Peimar reference document
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Peimar EN Installation Manual Photovoltaic Modules (general installation manual, linked from the maker's product page; English edition, Version EN_2024_12_00)
Archived copy of a document published by Peimar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
SG285P
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model SG285P listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under PEIMAR, as "SG285P". This is an equipment listing, not UL certification or complete-system approval.