Printed as "Frame Anodized" in Mission Solar PERC 60 335-350 W datasheet (SX5K), Page 2, mechanical data, Frame row. Revised on 1 October 2026: The data sheet prints the frame only as "Anodized" and does not name the metal, so the record must not add "aluminum".
Printed as "Rated Current Imp V 10.19 10.28 10.38 10.48" in Mission Solar Energy reference document, Page 2, electrical specification table, rated current (Imp) row, 350 W column. Revised on 1 October 2026: The data sheet prints 10.48 in the rated current (Imp) row of the 350 W column; the record value is right, and the conditions should quote that row instead of internal wording.
Where: Page 2, electrical specification table, rated current (Imp) row, 350 W column
Printed as "Short Circuit Current Isc V 10.85 10.91 10.97 11.05" in Mission Solar Energy reference document, Page 2, electrical specification table, short-circuit current (Isc) row, 350 W column. Revised on 1 October 2026: The data sheet prints 11.05 in the short-circuit current (Isc) row of the 350 W column; the record value is right, and the conditions should quote that row instead of internal wording.
Where: Page 2, electrical specification table, short-circuit current (Isc) row, 350 W column
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from the Standard Test Conditions block of the table whose power classes are 335 | 340 | 345 | 350; the 350 column is the one the catalog model MSE350SX5K names. Printed value: "33.41". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "Rated Voltage Vmp V", column "350"
Printed as "Open Circuit Voltage Voc A 40.35 40.53 40.71 40.95" in Mission Solar Energy reference document, Page 2, electrical specification table, open-circuit voltage (Voc) row, 350 W column. Revised on 1 October 2026: The data sheet prints 40.95 in the open-circuit voltage (Voc) row of the 350 W column; the record value is right, and the conditions should quote that row instead of internal wording.
Where: Page 2, electrical specification table, open-circuit voltage (Voc) row, 350 W column
Read from the publisher's own document for this exact model (Page 2, mechanical data, Solar Cells). The publisher prints no further test condition for this row; no value was taken from another model.
Read from the publisher's own document for this exact model (Page 2, mechanical data, Weight). The publisher prints no further test condition for this row; no value was taken from another model.
Read from the publisher's own document for this exact model (Page 2, mechanical data, Cell Orientation). The publisher prints no further test condition for this row; no value was taken from another model.
Staubli PV-KBT4/6II-UR and PV-KST4/6II-UR, MC4, Renhe 05-8
Read from the publisher's own document for this exact model (Page 2, mechanical data, Connector). The publisher prints no further test condition for this row; no value was taken from another model.
Printed as "Front Glass 3.2mm, tempered, low-iron, anti-reflective" in Mission Solar Energy's MSE350SX5K datasheet (Mission Solar PERC 60 335-350 W datasheet (SX5K)), captured on September 28, 2026.
Where: Datasheet page 2, MECHANICAL DATA, Front Glass row
Read from the publisher's own document for this exact model (Page 2, mechanical data, Junction Box). The publisher prints no further test condition for this row; no value was taken from another model.
Printed as "Front Glass 3.2mm, tempered, low-iron, anti-reflective Frame Anodized" in Mission Solar PERC 60 335-350 W datasheet (SX5K), Page 2, mechanical data, Front Glass and Frame rows. Revised on 1 October 2026: The data sheet prints a glass module in an anodized aluminum frame for this model, which is a rigid framed panel; the record should quote that printed construction.
Where: Page 2, mechanical data, Front Glass and Frame rows
W 1,054 × H 1,748 × D 40 mm / W 41.5 × H 68.82 × D 1.6 in converted
Read from the publisher's own document for this exact model (Page 2, mechanical data, Module Dimension). The publisher prints no further test condition for this row; no value was taken from another model.
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from the Standard Test Conditions block of the table whose power classes are 335 | 340 | 345 | 350; the 350 column is the one the catalog model MSE350SX5K names. Printed value: "350". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from a row the sheet prints once for every model it covers, including MSE350SX5K. Printed value: "A 20 20 20 20 Protection class IP67". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Read from the publisher's own document for this exact model (Page 2, operating conditions, Maximum System Voltage). The publisher prints no further test condition for this row; no value was taken from another model.
Where: Page 2, operating conditions, Maximum System Voltage
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from the Standard Test Conditions block of the table whose power classes are 335 | 340 | 345 | 350; the 350 column is the one the catalog model MSE350SX5K names. Printed value: "19.0". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
Where: PDF page 2, row "Module Efficiency %", column "350"
Read from the publisher's own document for this exact model (Page 2, operating conditions, Operating Temperature Range). The publisher prints no further test condition for this row; no value was taken from another model.
Where: Page 2, operating conditions, Operating Temperature Range
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from a row the sheet prints once for every model it covers, including MSE350SX5K. Printed value: "-0.361%/°C". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
Where: PDF page 2, row "Temperature Coefficient of Pmax -0.361%/°C"
Read from the publisher's own document for this exact model (Page 2, temperature coefficients, Isc). The publisher prints no further test condition for this row; no value was taken from another model.
Read from the publisher's own document for this exact model (Page 2, temperature coefficients, Voc). The publisher prints no further test condition for this row; no value was taken from another model.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from the Standard Test Conditions block of the table whose power classes are 335 | 340 | 345 | 350; the 350 column is the one the catalog model MSE350SX5K names. Printed value: "19.0". Conditions as stated on that sheet. No value was taken from another column, from the NMOT/NOCT block, or from a name.
MSE limited warranty: 25-year product cover applies to modules manufactured on or after 1 August 2019 (12 years before that date); 25-year limited power warranty.
MSE limited warranty: 25-year product cover applies to modules manufactured on or after 1 August 2019 (12 years before that date); 25-year limited power warranty.
0.361 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Read from the datasheet this catalog row already cites, at https://www.missionsolar.com/wp-content/uploads/2025/05/PERC-60-335-350-1.pdf, from a row the sheet prints once for every model it covers, including MSE350SX5K. Printed value: "-0.361%/°C". Conditions as stated on that sheet. A value the sheet states more than once with different readings was not used.
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
MSE350SX5K
Limitations
Model MSE350SX5K listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Mission Solar Energy LLC, as "MSE350SX5K", CEC listing date 2021-02-11. This is an equipment listing, not UL certification or complete-system approval.
MSE limited warranty: 25-year product cover applies to modules manufactured on or after 1 August 2019 (12 years before that date); 25-year limited power warranty.
MSE limited warranty: 25-year product cover applies to modules manufactured on or after 1 August 2019 (12 years before that date); 25-year limited power warranty.
Installation, handling and safety requirements for the MSE M6 series; it does not establish per-model electrical ratings.
Archived copies
Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Manufacturer datasheet for the MSExxxSX5K family; it names 335 W, 340 W, 345 W and 350 W columns only.
Archived copies
Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Limited product and power warranty terms for the MSE module line; durations depend on module manufacturing date and it publishes no electrical specifications.
Archived copies
Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Mission Solar Energy reference document
Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Module Installation and User Manual, M6 Series (P-SA2-UM-0009)
Archived copy of a document published by Mission Solar Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
MSE350SX5K
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model MSE350SX5K listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Mission Solar Energy LLC, as "MSE350SX5K", CEC listing date 2021-02-11. This is an equipment listing, not UL certification or complete-system approval.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.