Maxeon Solar Technologies SPR-E-Flex-110

By Maxeon Solar TechnologiesSKU SPR-E-Flex-110

Key specs

Units
SKU
SPR-E-Flex-110
Official datasheet
Sources

The model number SunPower printed in the Model row of SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020) ("Model SPR-E-Flex-110 SPR-E-Flex-100"); the title prints the second model as "SPR-E-FLEX-100". The datasheet prints no separate part number.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: Electrical Data at STC, Model row, column 1 of 2

Documented

Rated output (STC)
110 W
Official datasheet
Sources

Printed as "Nominal Power (Pnom) 50 W 100 W 110 W 170 W 170 W" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Voltage at max power (Vmp)
18.8 V
Official datasheet
Sources

Printed as "Rated Voltage (Vmpp) 17.7 V 17.1 V 18.8 V 29.9 V 29.4 V" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Current at max power (Imp)
5.9 A
Official datasheet
Sources

Printed as "Rated Current (Impp) 2.8 A 5.9 A 5.9 A 5.79 A 5.84 A" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Open-circuit voltage (Voc)
22.8 V
Official datasheet
Sources

Printed as "Open circuit voltage (Voc) 21.5 V 21.4 V 22.8 V 34.8 V 34.6 V" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Short-circuit current (Isc)
6.3 A
Official datasheet
Sources

Printed as "Short curcuit current (Isc) 3.1 A 6.3 A 6.3 A 6.10 A 6.15 A" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Power temperature coefficient
-0.3 %/°C
Maxeon documents differ: -0.3 or -0.29 %/°C

Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019) prints -0.3 %/°C for this model; SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) prints -0.29 %/°C. Both are shown; the installation manual is listed first.

Source installation manual
Sources

Printed as "Power Temp Coeffiecient –0.35%/° C –0.30%/° C –0.30%/° C" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1, Power Temp Coeffiecient row, SPR-E-Flex-110 column. Read from rendered page 3: the first cell (–0.35%/° C) spans the SPR-E-Flex-50 and SPR-E-Flex-100 columns, the second (–0.30%/° C) the SPR-E-Flex-110 column, the third both SPR-E-Flex-170 columns ("Coeffiecient" as printed). Revised on 1 October 2026: Owner source order puts the installation manual first: Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019) prints -0.3 %/°C for this model; the earlier value -0.29 %/°C came from SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) and is kept beside it.

-0.29 %/°C

Printed in the "Typical Electrical Data at STC" table of SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020), column 1 of 2 (the table heading defines STC as 25 °C, 1000 W/m2 and AM 1.5 and the header prints "Model SPR-E-Flex-110 SPR-E-Flex-100"); the row prints "Power Temp Coeffiecient –0.29%/° C –0.35%/° C". The datasheet spells the row label "Power Temp Coeffiecient". Voltage and current coefficients are printed only in mV/°C and mA/°C and are not converted. The 530842 Rev A sheet prints -0.30%/°C and the 523809 Rev E sheet prints a single -0.35%/°C for this model; both are kept as alternatives.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document
-0.3 %/°C

Printed as "Power Temp Coeffiecient –0.30%/° C –0.35%/° C" in SunPower's flexible panel datasheet Document # 530842 Rev A / A4_EN (©September 2018; Internet Archive copy captured September 20, 2019), column 1 of 2 (header "Model SPR-E-Flex-110 SPR-E-Flex-100").

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 datasheet (530842 Rev A, A4) (Internet Archive copy, September 20, 2019) Rev Document # 530842 Rev A / A4_EN · Checked · Earlier document
-0.35 %/°C

Printed once, as "Power Temp Coeffiecient –0.35%/° C", in SunPower's flexible panel datasheet Document # 523809 Rev E (©March 2018), the copy ExpertPower hosts and the catalog already archives as.

Official datasheet: sp E Flex 11 W ds en ltr 5 38 9E Checked · Earlier document
Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier document

Location: PDF page 3, Table 1, Power Temp Coeffiecient row, SPR-E-Flex-110 column

Documented

Cell technology
Prime monocrystalline 25% and 23% efficiency SunPower IBC cells
Official datasheet
Sources

Printed once for both models in the Mechanical Data block of SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020); the sheet does not say which cell efficiency belongs to which model, and it prints no cell count. SunPower's flexible panel datasheet Document # 523809 Rev E (©March 2018), the copy ExpertPower hosts and the catalog already archives as prints "Solar Cells 32 Prime monocrystalline SunPower IBC cells"; kept as an alternative.

Prime monocrystalline SunPower IBC cells

Printed as "Solar Cells 32 Prime monocrystalline SunPower IBC cells" in SunPower's flexible panel datasheet Document # 523809 Rev E (©March 2018), the copy ExpertPower hosts and the catalog already archives as once for both models.

Official datasheet: sp E Flex 11 W ds en ltr 5 38 9E Checked · Earlier document
Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: Mechanical Data, Solar Cells

Documented

Panel format
flexible
Official datasheet
Sources

SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020) is titled "SunPower® Flexible Solar Panels" and states the panels are built from light-weight polymer materials "allowing for easy transport, installation and panel flexing up to 30 degrees".

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: Title and High Power and Flexible section

Documented

3 specs not documented yet: module efficiency, maximum system voltage, bifacialHelp fill in ›

All specs21
Rated output (STC)
110 W
Official datasheet
Sources

Printed as "Nominal Power (Pnom) 50 W 100 W 110 W 170 W 170 W" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Module efficiency
Not documented
Official datasheet
Details

SunPower's flexible panel datasheet (Document # 523809 Rev G) prints "Solar Cells: Prime monocrystalline 25% and 23% efficiency SunPower IBC cells" in Mechanical Data, column 1 of 2 (110 W), which states the cell efficiency of the SunPower IBC cells used, not a module efficiency computed over the panel's full area; the datasheet prints no "Module Efficiency" row for SPR-E-Flex-110/100, so module_efficiency_pct is left unknown rather than substituted with the cell figure or computed from Pnom and panel dimensions.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Not documented

Voltage at max power (Vmp)
18.8 V
Official datasheet
Sources

Printed as "Rated Voltage (Vmpp) 17.7 V 17.1 V 18.8 V 29.9 V 29.4 V" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Current at max power (Imp)
5.9 A
Official datasheet
Sources

Printed as "Rated Current (Impp) 2.8 A 5.9 A 5.9 A 5.79 A 5.84 A" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Open-circuit voltage (Voc)
22.8 V
Official datasheet
Sources

Printed as "Open circuit voltage (Voc) 21.5 V 21.4 V 22.8 V 34.8 V 34.6 V" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Short-circuit current (Isc)
6.3 A
Official datasheet
Sources

Printed as "Short curcuit current (Isc) 3.1 A 6.3 A 6.3 A 6.10 A 6.15 A" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1 (Electrical Characteristics), SPR-E-Flex-110 column. Column 3 of 5 in the row, under the model header "SPR-E-Flex-110". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to SunPower Corporation (web.archive.org), which stays listed as an additional source.

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier documentOfficial datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: PDF page 3, Table 1 (Electrical Characteristics), SPR-E-Flex-110 column

Documented

Power temperature coefficient
-0.3 %/°C
Maxeon documents differ: -0.3 or -0.29 %/°C

Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019) prints -0.3 %/°C for this model; SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) prints -0.29 %/°C. Both are shown; the installation manual is listed first.

Source installation manual
Sources

Printed as "Power Temp Coeffiecient –0.35%/° C –0.30%/° C –0.30%/° C" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1, Power Temp Coeffiecient row, SPR-E-Flex-110 column. Read from rendered page 3: the first cell (–0.35%/° C) spans the SPR-E-Flex-50 and SPR-E-Flex-100 columns, the second (–0.30%/° C) the SPR-E-Flex-110 column, the third both SPR-E-Flex-170 columns ("Coeffiecient" as printed). Revised on 1 October 2026: Owner source order puts the installation manual first: Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019) prints -0.3 %/°C for this model; the earlier value -0.29 %/°C came from SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) and is kept beside it.

-0.29 %/°C

Printed in the "Typical Electrical Data at STC" table of SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020), column 1 of 2 (the table heading defines STC as 25 °C, 1000 W/m2 and AM 1.5 and the header prints "Model SPR-E-Flex-110 SPR-E-Flex-100"); the row prints "Power Temp Coeffiecient –0.29%/° C –0.35%/° C". The datasheet spells the row label "Power Temp Coeffiecient". Voltage and current coefficients are printed only in mV/°C and mA/°C and are not converted. The 530842 Rev A sheet prints -0.30%/°C and the 523809 Rev E sheet prints a single -0.35%/°C for this model; both are kept as alternatives.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document
-0.3 %/°C

Printed as "Power Temp Coeffiecient –0.30%/° C –0.35%/° C" in SunPower's flexible panel datasheet Document # 530842 Rev A / A4_EN (©September 2018; Internet Archive copy captured September 20, 2019), column 1 of 2 (header "Model SPR-E-Flex-110 SPR-E-Flex-100").

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 datasheet (530842 Rev A, A4) (Internet Archive copy, September 20, 2019) Rev Document # 530842 Rev A / A4_EN · Checked · Earlier document
-0.35 %/°C

Printed once, as "Power Temp Coeffiecient –0.35%/° C", in SunPower's flexible panel datasheet Document # 523809 Rev E (©March 2018), the copy ExpertPower hosts and the catalog already archives as.

Official datasheet: sp E Flex 11 W ds en ltr 5 38 9E Checked · Earlier document
Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier document

Location: PDF page 3, Table 1, Power Temp Coeffiecient row, SPR-E-Flex-110 column

Documented

Maximum system voltage
Not documented
Official datasheet
Details

SunPower's flexible panel datasheet (Document # 523809 Rev G) prints, in place of a numeric Max. System Voltage, "SPWR's flex panels are design to be used in battery charging applications, e.g. 12 V or 24 V batteries" and notes "SunPower Flex panels are presently not UL or IEC certified" for system voltages above 50 V DC; no numeric maximum system voltage is printed for SPR-E-Flex-110, so the field is left unknown rather than assigned 12 or 24 V (those are example battery voltages, not a stated system voltage rating).

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Not documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020)OfficialSunPower CorporationOfficial datasheet
    Source details
    Revision
    Document # 523809 Rev G / LTR_US
    Revision date
    Not stated

    Location: Typical Electrical Data at STC table; Mechanical Data; warranty statement

    Retrieved

    Not a live manufacturer document (the original address answered HTTP 404 on September 25, 2026). The document prints "Document # 523809 Rev G / LTR_US" and "©February 2019" and is published under the SunPower name, with SunPower Corporation as copyright holder. Figures describe the panel as documented in that revision.

    Archived copies

    Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Document # 523809 Rev G / LTR_US · 0.73 MB

    Archived copy, unaltered, kept as a record of what SunPower Corporation published. Original address: https://web.archive.org/web/20201025192135id_/https://us.sunpower.com/sites/default/files/sp-e-flex-110w-ds-en-ltr-523809_0.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    1
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: b31762d0bb829280d72771f5eaabcffaf2552921d2a0d4ac32ced67ab325ecaf

    Open
  • PDF
    SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022Maxeon Solar TechnologiesSource installation manualDecember 31, 2018
    Source details
    Revision
    REV F
    Revision date
    December 31, 2018

    Archived copy captured on 2026-10-01.

    Location: PDF page 1 (document number) and PDF page 3 (Table 1)

    Retrieved

    SunPower's own safety and installation instructions for its flexible photovoltaic modules, Document 524958 REV F (copyright 2019), applying to the modules in its Table 1: SPR-E-Flex-50, SPR-E-Flex-100, SPR-E-Flex-110 and SPR-E-Flex-170. SunPower (now Maxeon) no longer serves the file (404 on 1 October 2026); captured 1 October 2026 as the Internet Archive copy of June 5, 2022 of the file us.sunpower.com then served. REV F is the latest revision found. Manufacturer instructions, not independent tests.

    Open

Archive and older revisions

Archive and older revisions2

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • PDF
    SunPower Flexible Solar Panels SPR-E-Flex-110 datasheet (530842 Rev A, A4) (Internet Archive copy, September 20, 2019)OfficialSunPower CorporationOfficial datasheet
    Source details
    Revision
    Document # 530842 Rev A / A4_EN
    Revision date
    Not stated

    Location: Typical Electrical Data at STC table; Mechanical Data

    Retrieved

    Not a live manufacturer document (the original address answered HTTP 404 on September 25, 2026). The document prints "Document # 530842 Rev A / A4_EN" and "©September 2018" and is published under the SunPower name, with SunPower Corporation as copyright holder. Figures describe the panel as documented in that revision.

    Archived copies

    Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Document # 530842 Rev A / A4_EN · 0.69 MB

    Archived copy, unaltered, kept as a record of what SunPower Corporation published. Original address: https://web.archive.org/web/20190920182819id_/https://us.sunpower.com/sites/default/files/110w-flexible-panel-spec-sheet.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    1
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 130469c57b0a0cf0699266c9b90e821a5f68a33979cd875dfff816f4ac589699

    Open
  • PDF
    sp E Flex 11 W ds en ltr 5 38 9EOfficialSunPowerOfficial datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Document group: manual. Model naming in document text: not found.

    Location: Linked from https://www.expertpower.us/products/100w-sunpower-solar-panel with the link text "Download"

    Retrieved

    PDF downloaded from the link the manufacturer publishes on its own product page and preserved byte for byte. It establishes the document that link served on the access date; the document's text was read but does not repeat this exact SKU, so it is recorded as the document the manufacturer links for this product rather than as a per-SKU document. No revision history, issuer verification or currency of the link beyond the access date is established.

    Archived copies

    Archived copy of a document published by SunPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.64 MB

    Archived copy, unaltered, kept as a record of what SunPower published. Original address: https://cdn.shopify.com/s/files/1/2364/9089/files/sp_E_Flex_110W_ds_en_ltr_523809E.pdf?v=. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    1

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 1afbd40da782b8109e0d9e1c83ac36f6832b19ac9edd67f73a9822208ca85770

    Open

Archived documents

SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020)

Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Document # 523809 Rev G / LTR_US · 0.73 MB

Archived copy, unaltered, kept as a record of what SunPower Corporation published. Original address: https://web.archive.org/web/20201025192135id_/https://us.sunpower.com/sites/default/files/sp-e-flex-110w-ds-en-ltr-523809_0.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
1
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: b31762d0bb829280d72771f5eaabcffaf2552921d2a0d4ac32ced67ab325ecaf

sp E Flex 11 W ds en ltr 5 38 9E

Archived copy of a document published by SunPower. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.64 MB

Archived copy, unaltered, kept as a record of what SunPower published. Original address: https://cdn.shopify.com/s/files/1/2364/9089/files/sp_E_Flex_110W_ds_en_ltr_523809E.pdf?v=. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
1

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 1afbd40da782b8109e0d9e1c83ac36f6832b19ac9edd67f73a9822208ca85770

SunPower Flexible Solar Panels SPR-E-Flex-110 datasheet (530842 Rev A, A4) (Internet Archive copy, September 20, 2019)

Archived copy of a document published by SunPower Corporation. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Document # 530842 Rev A / A4_EN · 0.69 MB

Archived copy, unaltered, kept as a record of what SunPower Corporation published. Original address: https://web.archive.org/web/20190920182819id_/https://us.sunpower.com/sites/default/files/110w-flexible-panel-spec-sheet.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
1
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 130469c57b0a0cf0699266c9b90e821a5f68a33979cd875dfff816f4ac589699

Submit a document

Warranty

Warranted final output
80 %
Official datasheet
Sources

Printed in SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020) as "Warranty: 5 years limited power warranty of 80% of the minimum specified power rating.", that is 80% of the minimum specified power rating under the 5-year limited power warranty; the sheet names no year-by-year schedule.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: Warranty statement

Documented

Power warranty
5 years
Official datasheet
Sources

Printed in SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020) as "Warranty: 5 years limited power warranty of 80% of the minimum specified power rating." The sheet does not say who may claim it.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document

Location: Warranty statement

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

16/10037% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Module efficiency needed; Product warranty needed; First-year degradation needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiencyNot documented0.0 / 26.0

SunPower's flexible panel datasheet (Document # 523809 Rev G) prints "Solar Cells: Prime monocrystalline 25% and 23% efficiency SunPower IBC cells" in Mechanical Data, column 1 of 2 (110 W), which states the cell efficiency of the SunPower IBC cells used, not a module efficiency computed over the panel's full area; the datasheet prints no "Module Efficiency" row for SPR-E-Flex-110/100, so module_efficiency_pct is left unknown rather than substituted with the cell figure or computed from Pnom and panel dimensions.

Not documented. Undisclosed data scores 0.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document
Power warranty5 years2.7 / 16.0

5 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A460-MCE54Db 460W Dual-Glass Module

Printed in SunPower's flexible panel datasheet Document # 523809 Rev G (©February 2019; Internet Archive copy captured October 25, 2020) as "Warranty: 5 years limited power warranty of 80% of the minimum specified power rating." The sheet does not say who may claim it.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier document
Power temperature coefficient0.35 %/°C10.1 / 16.0

0.35 %/°C is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 0.22 %/°C, the lowest documented for a solar panel, printed by the maker: Jackery SolarSaga 100 Air

Printed as "Power Temp Coeffiecient –0.35%/° C –0.30%/° C –0.30%/° C" in Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019), Table 1, Power Temp Coeffiecient row, SPR-E-Flex-110 column. Read from rendered page 3: the first cell (–0.35%/° C) spans the SPR-E-Flex-50 and SPR-E-Flex-100 columns, the second (–0.30%/° C) the SPR-E-Flex-110 column, the third both SPR-E-Flex-170 columns ("Coeffiecient" as printed). Revised on 1 October 2026: Owner source order puts the installation manual first: Maxeon's SunPower Safety and Installation Instructions for flexible modules, Document 524958 REV F (2019) prints -0.3 %/°C for this model; the earlier value -0.29 %/°C came from SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) and is kept beside it.

The maker's documents disagree; the less favorable printed figure, 0.35 %/°C, is scored. Warning: Maxeon documents differ: -0.3 or -0.29 %/°C

Source installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier document
Weight / watt2.2 kg / 110 W3.1 / 5.0

0.02 against 0.01227 kg per W, the lowest documented for a flexible solar panel (calculated from maker figures): Go Power! 110-Watt Solar Flex™ Module

2.2 kg / 110 W. Lighter modules per watt carry less roof load.

Official datasheet: SunPower Flexible Solar Panels SPR-E-Flex-110 and SPR-E-FLEX-100 datasheet (523809 Rev G) (Internet Archive copy, October 25, 2020) Rev Document # 523809 Rev G / LTR_US · Checked · Earlier documentSource installation manual: SunPower Safety and Installation Instructions for flexible PV modules, Document 524958 REV F (2019), Internet Archive copy of June 5, 2022 Rev REV F · December 31, 2018 · Checked · Earlier document

Not documented, 0 points: Product warranty, First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SPR-E-Flex-110

Manufacturer SKU SPR-E-Flex-110 · US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.