Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: greentechrenewables.com's product image for the HIMO5 DC LR5-54HPB 415, used because no maker image of this model was found. Seller listing image, not a manufacturer-issued photo.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Current at max power | 13.11 A Provisional | Seller-listed specification; not independently verified. Where: max-power-current | [1] |
| Short-circuit current | 13.91 A Provisional | Seller-listed specification; not independently verified. Where: short-circuit-current | [1] |
| Voltage at max power | 31.66 V Provisional | Seller-listed specification; not independently verified. Where: max-power-voltage | [1] |
| Open-circuit voltage | 37.65 V Provisional | Seller-listed specification; not independently verified. Where: open-circuit-voltage | [1] |
| Cell type | Monocrystalline Provisional | Seller-listed specification; not independently verified. Where: technology | [1] |
| Grounding | There are grounding holes with the diameter of Ø4.2 mm at the edge location of module's back-side frame.; The copper core wire used for the grounding clamp is recommended to be 12 AWG.; Align grounding clamp to the frame mounting hole. Use grounding bolt to go through the grounding clamp and frame.; Put the tooth side of the washer on the other side and fasten the nuts. | Printed as "There are grounding holes with the diameter of Ø4.2 mm at the edge location of module's back-side frame." in section 7 (Grounding) of Installation Manual for LONGi Solar PV Modules V19, with the other quoted lines from the same section (one of LONGi's recommended grounding methods, a grounding clamp with grounding bolt and tooth washer). A third-party grounding device may be used if proved reliable. Where: PDF page 24, section 7 Grounding | [2] |
| Clamp torque | 12 to 16 N·m | Printed as "M8 bolt tightening torque range: 12-16 N•m; M6 bolt tightening torque range: 8-12 N•m" in section 5.2.2 (Clamp Mounting) of Installation Manual for LONGi Solar PV Modules V19; the value is the M8 bolt range printed as 12-16 N•m. The same section also states the M6 range of 8-12 N•m. Where: PDF page 14, section 5.2.2 Clamp Mounting, Suggestion 1 | [2] |
| Dimensions | W 1,134 × L 1,722 × D 30 mm / W 44.65 × L 67.8 × D 1.2 in converted Provisional | Seller-listed specification; not independently verified. Where: Dimensions | [1] |
| Rated power | 415 W Provisional | Seller-listed specification; not independently verified. Where: watts-stc | [1] |
| Series fuse | 25 A Provisional | Seller-listed specification; not independently verified. Where: series-fuse-rating | [1] |
| Mounting methods | Bolts Mounting, mounting rails cross the long frame: Outer Four-hole (Method ①) ±2400 Pa; Inner Four-hole (Method ②) +5400,-2400 Pa; Clamps Mounting, mounting rails cross the long frame (Method ③): 250≤D≤350 +5400,-2400 Pa; 350≤D≤450, 450≤D≤550 and 500≤D≤600 not given (/); Clamps Mounting, mounting rails cross the short frame, 150≤E≤250 (Method ④): ±2400 Pa; Clamps are mounted at the corners of short frame (Method ⑤): +2400,-1800 Pa | Printed as "LR5-54HPB-xxxM* ±2400 +5400,-2400 +5400,-2400 / / ±2400 +2400,-1800" in Installation Manual for LONGi Solar PV Modules V19; the method headings and clamp ranges for each cell were read from rendered page 16 (the text layer runs the cells together). All loads are maximum test loads in Pa, based on the static load requirements of IEC61215; the manual says a safety factor of 1.5 applies for the design load. The manual's applicable module table (PDF page 2) lists this type with certification status IEC、UL. Where: PDF page 16, table The maximum test load of framed mono-facial modules, LR5-54HPB-xxxM* row | [2] |
| Cable bend radius | The minimum allowed bending radius of cables should be 43mm. (1.69 inch) | Printed as "The minimum allowed bending radius of cables should be 43mm. (1.69 inch)" in section 6.2 of Installation Manual for LONGi Solar PV Modules V19, a statement for every module type the manual covers. Where: PDF page 23, section 6.2 Cables and Wiring | [2] |
| Max system voltage | 1,000 V Provisional | Seller-listed specification; not independently verified. Where: max-operating-voltage | [1] |
| Module efficiency | 21.3 % Provisional | Seller-listed specification; not independently verified. Where: efficiency | [1] |
| Temperature coefficient | -0.34 %/°C Provisional | Seller-listed specification; not independently verified. Where: temp-coefficient-pmpp | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Module efficiency needed; Product warranty needed; Power warranty needed; Power temperature coefficient needed; First-year degradation needed; Weight / watt needed.
Not enough comparable data for a score. None of this panel's scored inputs has a documented, sourced value yet. On file but not counted, because it is provisional, warned or has no source: module efficiency, power temperature coefficient.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
Seller-listed specification; not independently verified.
A value is on file but is not counted: it carries a warning or is not confirmed.
A documented panel weight and rated output are required.
Not documented. Undisclosed data scores 0.
Not documented, 0 points: Product warranty, Power warranty, First-year degradation.
Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4
How it worksUnknown: no certification evidence recorded in this data.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: Cover page (version) and PDF page 2, Applicable Module Type table (scope)
Retrieved Oct 1, 2026
LONGi's own installation manual for its framed PV modules, captured 1 October 2026 from static.longi.com, the file LONGi's global download center lists as Installation Manual for LONGi Solar PV Modules (published 17 October 2024); printed as V19 on the cover. Its applicable module table names LR5-54HPB-xxxM*, LR5-54HABB-xxxM*, LR5-72HBD-xxxM* and other LR5, LR7 and LR8 types with certification status IEC or IEC、UL, and its load tables also name LR5-72HBD-xxxM. It gives series-level mounting methods with test loads, torques, grounding and wiring instructions; it prints no model ratings. Manufacturer instructions, not independent tests.
Archived copy of a document published by LONGi. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what LONGi published. Original address: https://static.longi.com/Installation_Manual_for_LON_Gi_Solar_PV_Modules_V19_EN_8324ec0aa5.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fcc8e6de37e1576fed20dc65202e18f5bc37a0b22eb14b87f3a0ec5e62f5944c
Location: Product listing
Retrieved Sep 16, 2026
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Location: Seller-linked document
Retrieved Sep 16, 2026
Linked by the seller for this model; manufacturer revision and applicability need confirmation.
Archived copy of a document published by LONGi. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what LONGi published. Original address: https://static.longi.com/Installation_Manual_for_LON_Gi_Solar_PV_Modules_V19_EN_8324ec0aa5.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fcc8e6de37e1576fed20dc65202e18f5bc37a0b22eb14b87f3a0ec5e62f5944c
No sourced accessories or replacement parts listed yet.
Manufacturer SKU HIMO5 DC LR5-54HPB 415
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: panels-0.4-personal documented pct: 0 basis: Unknown missing: Module efficiency needed Product warranty needed Power warranty needed Power temperature coefficient needed First-year degradation needed Weight / watt needed criteria: key: efficiency label: Module efficiency value: Unknown unit: Unknown shown: 21.3 % · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 26 weight: 26 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: warranty label: Product warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 21 weight: 21 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: performanceWarranty label: Power warranty value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: powerTemperature label: Power temperature coefficient value: Unknown unit: Unknown shown: -0.34 %/°C · not confirmed shown detail: Unknown state: unconfirmed points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: no reason: not-counted reason text: A value is on file but is not counted: it carries a warning or is not confirmed. note: Not documented. display note: Unknown Sources: [1] key: degradation label: First-year degradation value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 16 weight: 16 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: weightPerWatt label: Weight / watt value: Unknown unit: Unknown shown: Not documented shown detail: Unknown state: missing points: 0 ceiling: 5 weight: 5 share: Unknown covered: no missing: yes folded: no reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: A documented panel weight and rated output are required. display note: Unknown Sources: [1] | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page